SunStone Power SLPO48-200 User manual

LITHIUM BATTERY PACK
USER MANUAL
MODEL: SLPO48-200
※Please read this manual before using the battery pack
※Please keep this manual properly after reading

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Room 5755, Adam-Opel-Straße 7-11 Komplek Duta Indah Iconic, Blok. C No. 2 Jl. Room 1803A, Tiley Central Plaza. Shenzhen, China
60386 Frankfurt (M), Germany MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 INDONESIA www.sunstonepwer.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
1. Product key parameters
NO. Specification
Item
56.8V±0.2V
51.2V
40V
200Ah (After standard charging, discharging at 0.5C.)
200Ah (After standard charging, discharging at 0.5C.)
Step 1: 50A constant current charge to 56.8V;
Step 2: 56.8V constant voltage charge until the charging current reaches
5A.
Temp.:0~45°C
5hours (for reference)
50A
100A
Charging: 0~45°C; Discharging: -20~55°C
1month: -20~45°C
3 months: -10~45°C
6 months: 0~25°C
humidity: 45~90% RH
The battery should be cycled every three months.
After 6000 cycles, at 25°C, 50A charge and discharge 80% DOD,
recoverable capacity ≥80%
≤90mΩ(50% capacity,AC impedance1kHz measuring)
About 90kg
52~53.5V
580(L)*483(W)*220(H)
Supports parallel connection of multiple battery pack (24units)
CAN and RS485
Black
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.15
1.16
1.17
1.18
1.19
1.20
Charging voltage
Nominal voltage
Cut-off voltage
Nominal capacity
Min. capacity
Standard charging
current and voltage
Charging time
Max charging current
Max. discharge current
Working Temp.
Storage Temp. and
humidity range
Cycle life
Battery weight
Ex-work voltage
Dimension
Function
Communication
Color
Initial battery
internal resistance
1.1
1.14
Appearance The battery pack surface is clean, free from scratches and mechanical
damage.

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Room 5755, Adam-Opel-Straße 7-11 Komplek Duta Indah Iconic, Blok. C No. 2 Jl. Room 1803A, Tiley Central Plaza. Shenzhen, China
60386 Frankfurt (M), Germany MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 INDONESIA www.sunstonepwer.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
3. Main function
2. Structural characteristics and interface definition
A. Basic structure: 2mm sheet metal box structure and rack.
B. Installation method: screw lock.
C. Surface coating: add spray paint.
3.1 Overall structure
The battery pack is mainly composed of the following parts: 4U metal outer box, a 16S2P modular,
accessories include: patch cord, external terminal post etc. The overall structure is simple and easy
to remove & maintain, high reliability, light weight and high energy density.
3.2 Interaction

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Room 5755, Adam-Opel-Straße 7-11 Komplek Duta Indah Iconic, Blok. C No. 2 Jl. Room 1803A, Tiley Central Plaza. Shenzhen, China
60386 Frankfurt (M), Germany MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 INDONESIA www.sunstonepwer.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
Item Buttons Rem ark
Up
Down
Enter
Esc
Indicator Light Run
Indicator Light Monitor
Indicator Light Normal
Indicator Light Alarm
If waking up fails, then please try to
wake it up after 10 seconds
Battery will automatcially in sleeping
mode if voltage is over low. It will
be woke up by recharging
1 2 3 4
OFF OFF OFF OFF Invalid address
OFF OFF OFF ON Address 1
OFF OFF ON OFF Address 2
OFF OFF ON ON Address 3
OFF ON OFF OFF Address 4
OFF ON OFF ON Address 5
OFF ON ON OFF Address 6
OFF ON ON ON Address 7
ON OFF OFF OFF Address 8
ON OFF OFF ON Address 9
ON OFF ON OFF Address 10
ON OFF ON ON Address 11
ON ON OFF OFF Address 12
ON ON OFF ON Address 13
ON ON ON OFF Address 14
ON ON ON ON Address 15
Communication
Interface RS485 Pin 3 is A, and Pin 5 is B
Encoder
Set up IP address by encoder if in communication situation
Warning/alarm
BMS
Indicator Light
Normal: Green light flashing
Alarm: Yellow light flashing
Faulty: Red light flashing
Red Button
In working status: Press 3 to 6 seconds to go into sleeping mode
In sleeping status: Press 3 to 6 seconds to wale up
Function
Display
Page up
Display only shows functions, can
not to be set
Page down
Confirm
Back to homepage
Running
Monitor communication status
Normal

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Room 5755, Adam-Opel-Straße 7-11 Komplek Duta Indah Iconic, Blok. C No. 2 Jl. Room 1803A, Tiley Central Plaza. Shenzhen, China
60386 Frankfurt (M), Germany MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 INDONESIA www.sunstonepwer.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
4.1 Temp. control threshold value
4.2 Voltage threshold value
4.3 Current threshold value
Level
Running normal
Alarm
Protect
Alarm
Protect
Alarm
Protect
Item
Normal operation temp.
Tpmin / Tpmax(°C)
10<Tpmin<35
-20<Tpmin≤-15
Tpmin≤-20
75≤Tpmax<85
Tpmax>85
60≤Tpmax<65
Tpmax>65
Battery cell voltage range (V)
2.5<Vmin≤2.9
Vmin≤2.5
2.9<V<3.65
3.65≤Vmax≤3.75
Vmax>3.75
Level
Alarm
Protect
Normal
Alarm
Protect
NO.
1
2
3
4
5
Parameter(A)
<75
75≤Imax≤105
Imax >105
Imax <800
Imax >800
Imax>1000
Item
Battery pack
Battery pack stack
Status
Normal
Alarm
Protect
Normal
Alarm
Protect
NO.
1
2
3
4
5
6
Low temp. threshold value
Radiator high temp. threshold value
Battery cell high temp. threshold value

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Room 5755, Adam-Opel-Straße 7-11 Komplek Duta Indah Iconic, Blok. C No. 2 Jl. Room 1803A, Tiley Central Plaza. Shenzhen, China
60386 Frankfurt (M), Germany MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 INDONESIA www.sunstonepwer.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
5. Daily use and maintenance of battery pack
5.1 Daily maintenance of battery pack
1. Check the voltage data on the BMS display and the actual battery voltage value to ensure the
accuracy of the voltage collection of the BMS. If they are inconsistent, proofreading is required. The
error between the collected voltage and the actual battery voltage does not exceed 10mV.
2. Check the temperature collection data and actual temperature value of the BMS, and the data
error between the collected data and the actual temperature value is not allowed to exceed 3℃, to
ensure that the battery will not be charged or discharged when the temperature is too high or too
low.
3. Check the BMS current collected data and actual current value, the error is not allowed to exceed
1%, to ensure that the battery will not be charged or discharged by overcurrent.
4. Check the reliability of the charging equipment to ensure that the charging equipment performs
charging according to the voltage and current regulationsent by the BMS, to ensure that the battery
will not be overcharged.
5. Check the connection of the battery pack is good, the contact points are in normal contact, and
there is no accumulation of dust, powder, metal chips.
5.2 Caution
1. Keep batteries or battery packs away from dangerous items or materials, such as corrosive chemi-
cals, dangerous machinery and equipment, and high-temperature environments.
2. Unreasonable use of this of products may cause smoke, such as external short circuit, overcharg-
ing, and high ambient temperature. If smoke occurs, please cut off the power in time, use carbon
dioxide or dry powder fire extinguisher for treatment, and bury it with sand or mud. The crowd must
be evacuated in time during the entire process.
3. Unreasonable use of this series of products may cause the single battery to swell. In severe cases,
it may cause the casing to rupture or crack. In these conditions, the battery should be stopped imme-
diately. Please contact our technical department or after-sales service department for further solu-
tion.
4. It is forbidden to short circuit the positive and negative terminal of the battery directly, and avoid
any metal or other conductive objects contacting the positive and negative terminal of the battery.
This operation may cause personal injury or property damage.
5. It is forbidden to immerse the battery in water or other conductive liquids. This operation may
cause personal injury or property damage.

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Room 5755, Adam-Opel-Straße 7-11 Komplek Duta Indah Iconic, Blok. C No. 2 Jl. Room 1803A, Tiley Central Plaza. Shenzhen, China
60386 Frankfurt (M), Germany MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 INDONESIA www.sunstonepwer.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
6. It is forbidden to use this product in series or parallel with other types of batteries. it is also for
bidden to conduct the entire power system in series or parallel operation. This operation may cause
personal injury or property loss. If necessary, please contact the relevant technical department to
obtain the correct technical support.
7. It is forbidden to get wet under the environment of more than 95%RH, even immerse in water.
Otherwise, it may cause internal short circuit, loss of function or abnormal chemical reaction, and
cause fire, smoke, explosion and other accidents.
8. It is forbidden to put the battery system into fire or to be exposed to a high temperature environ-
ment exceeding the temperature conditions specified in this specification for a long time. These
environments above the safe temperature range will cause a significant decrease in the performance
and life of this product, and even cause serious consequences such as combustion and explosion.
9. It is forbidden to store and use in an environment with high static electricity or high electromag-
netic radiation. Otherwise, the electronic devices in this product will be damaged, which may cause
potential safety hazards.
10. Connect the positive and negative terminal of the battery system strictly in accordance with the
instructions, and reverse charging is prohibited.
11. When the electrolyte leaks, avoid contacting the electrolyte with skin and eyes. In case of con-
tact, wash the area with plenty of water and seek medical assistance. It is forbidden for any person
or animal to swallow any part of the battery system or the substance contained in the battery
system.
Table of contents
Other SunStone Power Batteries Pack manuals
Popular Batteries Pack manuals by other brands

BYD
BYD HVL 12.0 quick start guide

National Instruments
National Instruments BP-1 installation guide

KitchenAid
KitchenAid KRB12 owner's manual

Minuteman
Minuteman Rack/Tower Extended Runtime Battery Packs user manual

rivacase
rivacase RIVAPOWER VA2002 Instructions and warnings

Clas Ohlson
Clas Ohlson WTD30552 operating instructions