Specications
Safety and Notes
Operating Voltage Range 100–277 VAC
Total Power Consumption 18 W
Current Draw 0.15 A@120 VAC
Beam Angle NEMA 2x2 (20°x20°)
Operating Temperature -40°–122° F(-40°–50° C)
Environmental Rating IP65
Dimmable No
Model WN-FL01-RD01
• Product should be installed and serviced in accordance with
applicable national, state, and local building and electrical codes.
• To reduce the risk of electric shock, ensure that the main power
source and circuit breakers are switched o before performing
any installation or wiring procedures.
• Avoid looking directly into lamp when illuminated.
• Ensure all mounts are securely attached and will support the
weight of the xture. Failure to properly support xture may result
in damage or injury, for which the manufacturer does not
assume responsibility. AFL-50K50-110-U
Wiring Diagram
Line
Neutral
Ground
Black
L L
N N
GND GND
White
Dim (+)
Dim (-)
Purple
+ +
- -
Gray
Green
User Manual
Installation Instructions (U-bracket/Yoke Mount)
1. Drill holes for mounting and wiring as needed.
2. Securely attach light to surface and connect wiring.
3. Apply power and rotate light head to desired angle.
Drill hex-key