Safety and Notes
Operating Voltage Range 120–277 VAC
Total Power Consumption 15 W 30 W 50 W 70 W 100 W
Current Draw 0.13 A @120 VAC 0.25 A @120 VAC 0.42 A @120 VAC 0.58 A @120 VAC 0.83 A @120 VAC
Beam Angle NEMA 5x6 (80°x110°)
Operating Temperature -40°–113° F (-40°–45° C)
Environmental Rating IP65
Dimmable No
Specications AFL-xK15-110-x AFL-xK30-110-x AFL-xK50-110-x AFL-xK70-110-x AFL-xK100-110-x
• Product should be installed and serviced in accordance with
applicable national, state, and local building and electrical codes.
• To reduce the risk of electric shock, ensure that the main power
source and circuit breakers are switched o before performing
any installation or wiring procedures.
• Avoid looking directly into lamp when illuminated.
• Ensure all mounts are securely attached and will support the
weight of the xture. Failure to properly support xture may result
in damage or injury, for which the manufacturer does not
assume responsibility. AFL-50K50-110-U
Wiring Diagram Line
Neutral
Ground
Black
L L
N N
GND GND
White
Dim (+)
Dim (-)
Purple
+ +
- -
Gray
Green
User Manual
Installation Instructions (U-bracket/Yoke Mount)
black L
white N
green
water-proof gasket
lamp
wires
cover of junction-box
screw
knuckle mount
Drill Wall
hex-key
1. Drill holes for mounting and wiring.
2. Loosen light head adjustment screws with hex key.
3. Securely attach light to wall and connect wiring.
4. Rotate light head to desired angle and tighten adjustment screws.