Humidity Temperature Controller
Thank you for using Swastik Humidity Temperature Controller.
This instruction describes product function, features and
proper usage.
Content Index
S1
!!
Warning
Note
1. For heat radiation, leave space around the instrument and do
not jam the ventilation holes in the instrument
2. Keep enough space between the instrument and equipment
which generates high frequency and surge.
3. Connect wires correctly
4. Use the instrument under rated load and power supply.
5. Use standard grade of alcohol to clean the instrument; don't use
paint thinner or similar chemicals
6. Read and understand this instruction carefully before use
7. Don't use the instrument in case the front panel peels of breaks.
1. To avoid electric shock, DON’T touch the AC power supply
terminals after power on.
2. Before power on, please confirm voltage conformity in range of
AC 210~240V, to avoid damage to instrument.
3. Never remove, retrofit or repair the product or contact any
internal components.
4. Tighten screw with 0.74-0.90Nm torque, as loose screws may
cause fire.
5. Use appropriate fuse to ensure power supply line and
input / output line to prevent current impact.
6. Don't use the instrument in occasion of flammable,
explosive gas, discharge of steam.
Warning
Note
S1
Features
S2
S2 Features
Technical specification
Parameter Setting
S3
S4
LED Indication
Set Key
When Instrument Power On, Press key Display message as below
Shift Key UpKey Ent key
Upper Display window
Lowe Display window
S3 Panel instruction
Panel instruction
S4 Parameter Setting
S5
S6
Parameter Description
Wiring diagram
Indicational / Controlling of Temperature and Humidity
Programmable resolution setting for Temp+RH
Easy to operate
Build in Relay contacts
High Accuracy of Temp+RH
Excellent quality, safety and strong resistance to interference
DTC-9621-1
SET
Temperature / Humidity Controller
ENT
Swastik
SET
O/P1
°c
%
O/P2
888.8
888.8
Automation & Control
Model No: DTC-9621-1
Input specification of Sensor :
Measuring range of Sensor :
Measuring accuracy :
Adjustment method :
Control Action :
Relay contact :
Size of instrument :
Panel cutout :
RTD / PT-100
Rh Sensor
RTD -50~400.0°C
0 - 100 % Rh
0.5 % of FSD (± 1°C)
Features Touch key pad
Temp. & Humidity
230 vac/5Amp
96x96x90 mm
92x92x90 mm
+
100.0
2
50
2
0025
HEAT
0001
COOL
SETT
HY-T
SETH
HY-H
PASS
T-AC
T-DL
T-AC
SET
Press key
SET
Press key
SET
Press key
SET
Press key 3 Sec.
SET
Press key
SET
Press key
Use & key to set value for the Temperature
Use & key to set value for the Humidity
Use & key to Hysteresis value (Temperature)
Use & key to Hysteresis value (Humidity)
Use & key to set Password
Use & key
Use & key to select
Temperature Action
(Heat / Cool)
Temperature Action
Technical Specification
HY
0020
0400
0100
0004
PID
Mode
KPT
Kit
Kdt
CTT
Mode
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
Control Mode (Action)
Hy (On-Off)
Or
PID
Continue ..................
Comp. Time delay (Min)