Introduction
Thank you for purchasing the Sykes-Pickavant Carbon Tec HHO
Machine. Before using the machine for the rst time, please read this
manual thoroughly and follow the instructions carefully.
This machine is designed to apply hydrogen into a combustion engine’s
air inlet system. When ingested into a running engine, the hydrogen
gently loosens internal carbon deposits which can prevent efcient
engine operation. The loosened deposits pass through the engine and
exhaust pipe, leaving behind a cleaner, more efcient engine.
You should allow 30 – 60 minutes per operation for optimum results.
Guarantee
This machine is guaranteed against faulty manufacture for a period of 2
years from the date of purchase. Please retain your receipt for proof of
purchase. Faulty goods should be returned to their place of purchase.
This guarantee is invalid if the machine has been abused or tampered
with in any way, or if it has not been used for the purpose for which it
was intended.
This guarantee does not affect your statutory rights.

Sykes-Pickavant Ltd, Unit 4 Cannel Road, Burntwood Business Park, Burntwood, Staordshire, WS7 3FU.
United Kingdom
Tel: +44 (0) 1543 679900 Fax: +44 (0) 1543 679901
e-mail: sales@sykes-pickavant.com www.sykes-pickavant.com
COPYRIGHT 2018 - SYKES-PICKAVANT LTD. ALL RIGHTS RESERVED. ALL PRODUCTS SUBJECT TO AVAILABILITY. E&OE.
Specialist Tool Solutions
Safety Precautions
ATTENTION: Hydrogen can be explosive. Do not smoke or use naked
flames near the machine
Only use in a well-ventilated area
Machine must be connected to a 12V battery - never use a mains battery
charger or battery support unit, as the AC power output may damage the
machine. This will not be covered under warranty and subsequent repair
costs will be charged.
Vehicle checks before use:
• Check there are no serious engine faults - if present, repair before
using the machine
• Check no error codes are present - if present, clear them before use
• Check vehicle oil and coolant levels are correct

Sykes-Pickavant Ltd, Unit 4 Cannel Road, Burntwood Business Park, Burntwood, Staordshire, WS7 3FU.
United Kingdom
Tel: +44 (0) 1543 679900 Fax: +44 (0) 1543 679901
e-mail: sales@sykes-pickavant.com www.sykes-pickavant.com
COPYRIGHT 2018 - SYKES-PICKAVANT LTD. ALL RIGHTS RESERVED. ALL PRODUCTS SUBJECT TO AVAILABILITY. E&OE.
Specialist Tool Solutions
Hydrogen Cleaning Machine Diagram
Easy carry handle
Hose fitting
HHO reservoir
viewing window
Power switch (on/off)
Fan
Hose storage hooks

Sykes-Pickavant Ltd, Unit 4 Cannel Road, Burntwood Business Park, Burntwood, Staordshire, WS7 3FU.
United Kingdom
Tel: +44 (0) 1543 679900 Fax: +44 (0) 1543 679901
e-mail: sales@sykes-pickavant.com www.sykes-pickavant.com
COPYRIGHT 2018 - SYKES-PICKAVANT LTD. ALL RIGHTS RESERVED. ALL PRODUCTS SUBJECT TO AVAILABILITY. E&OE.
Specialist Tool Solutions
Preparation & Operating Instructions
Before rst use: Please note that when you take the machine out of the
box, the machine will be blanked off (to remove this plug, use the tool
provided) to ensure that no fluid has been lost during transit. On rst use,
a small amount of electrolyte may be discharged from the tting when
the blanking plug is removed – this should be captured and disposed of
as a mild alkali solution. The hose can then be plugged into the machine.
1. Start the vehicle to be treated and idle the car until the engine
reaches operational temperature. Make sure all engine loads (e.g.
lights, air conditioning etc.) have been switched off.
2. Park the vehicle either outside,
or with the exhaust positioned
towards the outside of a
workshop, and make sure the
area is well-ventilated. This is
to ensure that any released
exhaust emissions do not
enter the building, or use
exhaust extraction.
3. Turn off the car before
connecting the cleaning
machine to the battery. Place
the machine on dry, level
ground and, if using outdoors,
ensure it is protected from any
rainfall. Ensure the power
switch on the machine is set
to the ‘off’ position.

Sykes-Pickavant Ltd, Unit 4 Cannel Road, Burntwood Business Park, Burntwood, Staordshire, WS7 3FU.
United Kingdom
Tel: +44 (0) 1543 679900 Fax: +44 (0) 1543 679901
e-mail: sales@sykes-pickavant.com www.sykes-pickavant.com
COPYRIGHT 2018 - SYKES-PICKAVANT LTD. ALL RIGHTS RESERVED. ALL PRODUCTS SUBJECT TO AVAILABILITY. E&OE.
4. Access the vehicle battery and connect the crocodile clips on the
machine onto the battery. The RED clamp needs to be connected to
the positive battery terminal, and the BLACK clamp needs to be
connected to the negative terminal. Incorrect connection will blow
the fuse.
5. Turn the car engine back on. Switch the cleaning machine on - a
blue internal light indicates that the machine is on and functioning.
6. Insert HHO hose into a small container of water to check Hydrogen
is being produced (i.e. bubbles).
7. Insert HHO hose into the vehicle’s air induction inlet and where
possible before air flow sensor.
8. Run the vehicle at tick over up to 60 minutes. Every 10 minutes,
apply fast full throttle usage at the same time, in order to allow the
engine to clear out any loosened carbon deposits.
9. At the end of the process, switch the cleaning machine off and run
the vehicle’s engine for a further 2 minutes or more, to use up all
the hydrogen gas which may be in the delivery hose. Switch off
engine and disconnect the battery clamps. Remove the HHO hose,
ret the vehicle air inlet and test.
Specialist Tool Solutions

Sykes-Pickavant Ltd, Unit 4 Cannel Road, Burntwood Business Park, Burntwood, Staordshire, WS7 3FU.
United Kingdom
Tel: +44 (0) 1543 679900 Fax: +44 (0) 1543 679901
e-mail: sales@sykes-pickavant.com www.sykes-pickavant.com
COPYRIGHT 2018 - SYKES-PICKAVANT LTD. ALL RIGHTS RESERVED. ALL PRODUCTS SUBJECT TO AVAILABILITY. E&OE.
Specialist Tool Solutions
Relling the fluid reservoir
Do not top up or add to this fluid level with anything other than
Sykes-Pickavant HHO Replacement Fluid - 53400400, as this will affect
the operation of the machine. The level of fluid within the reservoir can
be viewed through the window on the front of the machine. When the
level reaches the minimum level please contact customer services for
53400400 replacement fluid.
NOTE: If the fluid level falls below the minimum level line, the machine
will stop producing HHO. It will automatically recommence HHO
production when lled.
To ll the HHO reservoir
• Loosen the 4 screws on the panel on the top of the machine and
remove panel
• Remove cap from reservoir and add HHO fluid to the max level -
max/min fluid levels can be monitored through the viewing window
• Replace cap and panel
• Use of a different fluid may lead to operating problems with the
machine and will void the warranty

Sykes-Pickavant Ltd, Unit 4 Cannel Road, Burntwood Business Park, Burntwood, Staordshire, WS7 3FU.
United Kingdom
Tel: +44 (0) 1543 679900 Fax: +44 (0) 1543 679901
e-mail: sales@sykes-pickavant.com www.sykes-pickavant.com
COPYRIGHT 2018 - SYKES-PICKAVANT LTD. ALL RIGHTS RESERVED. ALL PRODUCTS SUBJECT TO AVAILABILITY. E&OE.
Specialist Tool Solutions
EC Declaration of Conformity
in accordance with BS/EN/ISO/IEC17050-1:2010
Equipment Description Carbon Tec HHO Machine
Manufacturer/Supplier Sykes-Pickavant Ltd.
Address Unit 4, Cannel Road, Burntwood Business Park, Burntwood,
Staffordshire, WS7 3FU
Directives: EMC 2014/30/EU Electromagnetic Compatibility
LVD 2014/35/EU Low Voltage Directive
ROHS2 2011/65/EU Restriction of Hazardous Substances
International Standards EN 61 326:2013 EMC emissions / immunity
EN 61010-1:2010 LVD Electrical Safety
Tests carried out by: Stafford Aero Technologies EMC Test Dept.
4 Chalk Hill House, 19 Rosary Road, Norwich, Norfolk, NR1 1SZ, UK
Declaration: We hereby declare that the equipment complies with the required
Directives stated above.
Authorised by
…………………………………..
Position………………………….
Date…………………………….
All rights reserved. No part of this document may be reproduced in any material form (including photocopying or storing in any medium by electronic means and whether
or not transiently or incidentally or some other use of this document) without the written permission of the copyright holder.
E.A.O.E
This manual suits for next models
1
Table of contents