manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Symmons
  6. •
  7. Control Unit
  8. •
  9. Symmons 3DIVBODYSRT Manual

Symmons 3DIVBODYSRT Manual

Model Numbers
Triple Outlet Diverter
Operation & Maintenance Manual
3DIVBODYSRT
Triple outlet diverter valve features shared functionality
and includes dened detents. Inlet and outlet connections
are both 1/2" male IPS & 1/2" female sweat. Components
made from lead free metal construction.
Specification
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Compliance
Dimensions
Notes:
1) Figure is determined by style of trim attached to shower valve. See rough-in
dimension drawing for shower valve application with diverter valve.
2) Dimensions subject to change without notice.
3DIVBODYSRT
Triple Outlet Diverter
-ASME A112.18.1/CSA B125.1
BB
ININ
OUTOUT
OUTOUT
AA
OUTOUT
CC
DD
FF
GG
EE
Measurements
A 2-5/8", 67 mm
B
Screwless Escutcheons
Hole Size
Min. Ø 3", 76 mm
Max. Ø 3-1/4", 83 mm
C
Screw Escutcheons
Hole Size
Min. Ø 1-3/4", 44 mm
Max. Ø 2", 51 mm
D 5-1/4", 133 mm
E(4x) 1/2" male IPS &
(4x) 1/2" sweat
F See note 1
G 4-7/8", 124 mm
2
Parts Breakdown
Tools Required
Adjustable
Wrench
Drill (optional)
Plumber Tape
Safety Glasses
Solder
Torch
Replacement Parts
Item Description Part Number
A Cap Assembly RTS-DIVCAP-
SRT
C Cartridge Extender RTS-DIVEXT-
SRT
D
F
Cartridge
Retaining Sleeve RTS-3DIV
B
G
H
I
Spacer
1" Cap Extender
1" Cartridge Extender
4" Mounting Screws
RTS-DIV-1EXT
E
FROM SHOWER VALVE
DIVERTER FUNCTION 1
DIVERTER FUNCTION 2
DIVERTER FUNCTION 3
C
D
AB
G
H
B
I
Important:
Cartridge (D)
must be installed
with arrow
facing down.
Important: Do not plug outlet ports. Do not use diverter as shut
off valve.
Note: Diverter valve can be installed in wall with shower valve or in
an adjoining wall to shower valve.
Important: Do not expose diverter valve to heat for longer than 2
minutes when sweating in copper tubing. Doing so may damage
the internal components of the valve and will void the product
warranty.
3
Installation
1) Reference rough-in dimension for
shower application with diverter
for proper installation of diverter
valve.
5) Sweat 1/2" copper tubing from
inlet port on diverter valve
to water source. Sweat 1/2"
copper tubing from outlet ports
to desired accessories.
2) Shut-off water supplies.
4) Secure stringer mounts on diverter
valve (E) to wood blocking for
support.
E
!
E
3) Position diverter valve (E) so port
marked IN is facing down.
3
2
Optional: Apply plumber tape to
male IPS threads on the inlet and
outlet ports of diverter valve. Install
1/2"-14 NPT copper ttings to the
inlet and outlet ports. Connect
outlets to desired accessories.
Note: Securing stringer mounts is
necessary for applications where
PEX, or other non rigid tubing, is
used to install diverter valve.
Operation
1
POSITION 1
1) Cartridge is factory set to divert
to function 1.
POSITION 2
2
2) Turn handle to position 2 to divert
to function 2.
POSITION 3
3
3) Turn handle to position 3 to divert
to function 3.
POSITION 4
2
3
4) Turn handle to position 4 to share
functions 2 and 3.
POSITION 5
3
1
5) Turn handle to position 5 to share
functions 1 and 3.
POSITION 6
2
1
6) Turn handle to position 6 to share
functions 1 and 2.
6) Turn on water supplies to ush
plumbing lines free of debris
.
Check for leaks.
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2019 Symmons Industries, Inc. ■symmons.com ■[email protected] ■ZV-3293 REV 0 ■ 031919
Troubleshooting Chart
E
2
A
C
D
F
1
1) Remove cap assembly (A) from
diverter valve by turning coun-
terclockwise. Remove cartridge
extender (C), cartridge (D) and
retaining sleeve (F) from diverter
valve.
DE
2)
Inspect cartridge for debris.
Replace cartridge if necessary.
4) Align spindle extender (C) with
broach on cartridge (D). Install
spindle extender (C) and cap
assembly (A) to cartridge (D).
Secure cap assembly (A) by
turning clockwise.
1
A
C
D
2
Notes:
1) Use caution not to dislodge
cartridge from valve body when
installing cap assembly (A).
2) Tighten cap assembly (A) to
75
±
5 lbf-in of torque.
Note: Spacer (B) will be seated
inside cap assembly (A).
Maintenance (Cartridge Replacement)
3) Align pegs on cartridge (D) with
indents inside diverter valve (E).
Retaining sleeve (F) must be
inserted ush into diverter valve
before installing cartridge (D).
Important: Cartridge (D) must be
installed with arrow
facing down.
Problem Cause Solution
Diverter valve will not divert water.
Foreign matter in water supply may
cause blockages in plumbing lines and
the diverter valve cartridge.
Remove cartridge from diverter valve.
Flush lines free of foreign matter.
Inspect cartridge for debris. Replace
cartridge if necessary.
Water is leaking from the face of the
diverter valve.
Cap assembly is not fully sealed to
diverter valve.
Remove cap assembly. Inspect
threads for debris. Reinstall cap
assembly to diverter valve at
75
±
5
lbf-in of torque.
Diverter trim will not install to diverter
valve.
Diverter valve body rough-in is too
deep.
Use RTS-DIV-1EXT to extend diverter
stem 1 inch.
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Other Symmons Control Unit manuals

Symmons 7-102 Manual

Symmons

Symmons 7-102 Manual

Symmons Temptrol S261BODY User manual

Symmons

Symmons Temptrol S261BODY User manual

Symmons LaundryMate LM600 Manual

Symmons

Symmons LaundryMate LM600 Manual

Symmons Maxline 7-225 Series Manual

Symmons

Symmons Maxline 7-225 Series Manual

Symmons Maxline 7-210-CK Manual

Symmons

Symmons Maxline 7-210-CK Manual

Symmons 7-210-CK Manual

Symmons

Symmons 7-210-CK Manual

Symmons Evolution EVOFQ038KIT User manual

Symmons

Symmons Evolution EVOFQ038KIT User manual

Symmons Temptrol 262BODY User manual

Symmons

Symmons Temptrol 262BODY User manual

Symmons 2DIVBODYNSSRT Manual

Symmons

Symmons 2DIVBODYNSSRT Manual

Symmons LaundryMate LM600 Manual

Symmons

Symmons LaundryMate LM600 Manual

Symmons Temptrol 262XBODY User manual

Symmons

Symmons Temptrol 262XBODY User manual

Symmons Showeroff 4-420 Manual

Symmons

Symmons Showeroff 4-420 Manual

Symmons Temptrol VersaFlex S262BODY User manual

Symmons

Symmons Temptrol VersaFlex S262BODY User manual

Symmons Temptrol II Operation manual

Symmons

Symmons Temptrol II Operation manual

Symmons Maxline 8210CK Manual

Symmons

Symmons Maxline 8210CK Manual

Symmons 2DIV-BODY-NS Manual

Symmons

Symmons 2DIV-BODY-NS Manual

Popular Control Unit manuals by other brands

Siemens 7KM9300-0AE01-0AA0 operating instructions

Siemens

Siemens 7KM9300-0AE01-0AA0 operating instructions

Eltek PSR312 user manual

Eltek

Eltek PSR312 user manual

Dwyer Instruments DP3 Series Installation and operating instructions

Dwyer Instruments

Dwyer Instruments DP3 Series Installation and operating instructions

Atlas Copco MT Focus 400 Product instructions

Atlas Copco

Atlas Copco MT Focus 400 Product instructions

Azel i-Link SZ-V4 Installation and operating instructions

Azel

Azel i-Link SZ-V4 Installation and operating instructions

vds AT 7070 Technical installation manual

vds

vds AT 7070 Technical installation manual

HPE JH182A user guide

HPE

HPE JH182A user guide

Alphacool Heatmaster 2 instruction manual

Alphacool

Alphacool Heatmaster 2 instruction manual

Kilowatt Labs Sirius 7100-48-B-2C-M-SD-A-G user manual

Kilowatt Labs

Kilowatt Labs Sirius 7100-48-B-2C-M-SD-A-G user manual

Yoshitake BSV-10F product manual

Yoshitake

Yoshitake BSV-10F product manual

Pfeiffer 14c Series maintenance

Pfeiffer

Pfeiffer 14c Series maintenance

Renesas DA16200 PMOD Getting started guide

Renesas

Renesas DA16200 PMOD Getting started guide

IBM WebSphere DataPower XI50B Installation and user guide

IBM

IBM WebSphere DataPower XI50B Installation and user guide

Topway LMT050DNCFWU-NWN user manual

Topway

Topway LMT050DNCFWU-NWN user manual

FRC InControl TGA300 manual

FRC

FRC InControl TGA300 manual

Spectron BM50 Series operating manual

Spectron

Spectron BM50 Series operating manual

ICM Controls ICM292 Installation

ICM Controls

ICM Controls ICM292 Installation

Armstrong GD-10 Installation and maintenance instructions

Armstrong

Armstrong GD-10 Installation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.