manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Symmons
  6. •
  7. Control Unit
  8. •
  9. Symmons Evolution EVOFQ038KIT User manual

Symmons Evolution EVOFQ038KIT User manual

Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Evolution Flow Sensor Module, Clamp-on Meter
Installation Guide
Model Numbers Feature Highlights
☐EVOFQ038KIT FLOW SENSOR, Clamp-on Meter,
1/4" to 3/8"
☐EVOFQ075KIT FLOW SENSOR, Clamp-on Meter,
1/2" to 3/4"
☐EVOFQ125KIT FLOW SENSOR, Clamp-on Meter,
1" to 1-1/4"
☐EVOFQ200KIT FLOW SENSOR, Clamp-on Meter,
1-1/2" to 2"
• Flow Sensor Meter
• 24V DC Power Supply 60"
• 30 Foot M12 Cable
• Clamp-On Meter - Pipe Sizes ranging from 1/4" to
1-1/2" - Please see "Supported Pipe Diameter" Chart on
dimension page for appropriate sizing.
Location:
Compliance
• IC: 24889-WW08189
• FCC ID: 2ASQP-WW08189
This device complies with part 15 of the FCC Rules.
Limited Lifetime - to the original end
purchaser in consumer/residential
installations.
10 Years - for commercial/industrial
installations. Refer to
www.symmons.com/warranty for
complete warranty information.
Warranty
Symmons Evolution EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT, EVOFQ200KIT Includes flow sensor module, 24 V
DC power supply, 30 foot M12 cable, and clamp-on meter (pipe sizes ranging from 1/4” to 1-1/2”). 10 Year Commercial
Warranty. FCC rules compliant.
Architectural/ Engineering Specification
Repair Parts
☐EVOAPWR24 Replacement Power Supply
24VDC
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
A
C
D
E
PCBA Plug
30 Feet
M12
Power Jack
B
1-11/16”
60”
Power Supply
24C DC
Evolution Sensor
Module
Dimensions - Flow Sensor (Included in Kit)
Measurement
A1-7/16"
B1-5/8"
C5"
D3-7/8"
E6-1/2"
X 4
X 12
Mounting Hardware
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Dimensions - Clamp On Meter (Included in Kit)
For securing main body to pipe
M4 Thread X 2 -
P0.7, Length 16mm, SUSXM7
106
101
106
B
Pipe Outside Diameter
36
38
A
C
Clamp on Meter Dimensions (mm)
Model A B C
EVOFQ038KIT 38 38 25.3
EVOFQ075KIT MAX 2.5 48 30
EVOFQ125KIT MAX 4.2 67 46.7
EVOFQ200KIT MAX 3.6 88 56
Supported Pipe Diameter
Model EVOFQ038KIT EVOFQ075KIT EVOFQ125KIT EVOFQ200KIT
Outer Diameter (mm) Ø12 to Ø16 Ø16 to Ø18 Ø18 to Ø23 Ø23 to Ø28 Ø28 to Ø37 Ø37 to Ø44 Ø44 to Ø52 Ø52 to Ø64
NPS (Nominal Pipe Size) 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"
DN (Diameter Nominal) 8 A 10 A 15 A 20 A 25 A 32 A 40 A 50 A
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Installation Training Checklist
Setup Custom on Evolution App
Install Gateway
Install Temperature Sensor
Install Pipe Clamp-On Flow Sensor
Configure System
1. Open the Box and Find a location to plug in the Gateway
2. Unpack, assemble, and plug Gateway to 120VAC Supply
3. Creates and Configure Customer Property
4. Creates Customer account and send Email Invitation
5. Customer Logs into water.symmons.com
6. Download the Evolution App for iOS or Android and Sign-In
7. Scan Gateway QR Code and Complete App Steps
8. Plug a Temperature Probe into a Sensor Module and Turn ON
9. Install Temperature Sensor
10. Scan Temperature Sensor Module and Complete App Steps
11. Plug Clamp-on Keyence Sensor Probe into Sensor Module and plug power supply
into a 120VAC outlet
12. Install Clamp-on Flow Sensor onto pipe
13. Scan Sensor Module and Complete App Steps
14. Setup Other Users
15. Configure Alerts
16. Set Meeting for System follow-up (1-2 weeks from Training)
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
A. Locate Gateway, Power
Adapter, (1x) Thin Antenna,
(2x) Wide Antennas
B. Connect Antennas and Pow-
er Adapter to the back of
the Gateway
Install Gateway
1. Location
1. Connect Gateway Hardware
Mechanical Room Admin. Oce Front Desk
Find a central location for the Gateway. Location should be a secure area not enclosed
in metal. Recommended locations include:
Note: After plugging the Gateway power adapter into an outlet, it could take a few minutes to boot up.
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Customer App Setup
1. Create and Configure Customer Property
2. Create Customer account & send Email Invitation
3. Customer Logs into water.symmons.com
4. Download the Evolution App for iOS or Android and Sign-In
5. Scan Gateway QR Code and Complete In-app Steps
Scan the Provided QR Code with your
Smartphone or camera to download the
evolution App.
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Installation - Pipe Clamp-On Flow Sensor
1. Setup Custom on Evolution App
2. Find the best location to mount.
Tools Required
•Philips-head screwdriver
•The pipe measuring kit include in welcome pack
•Measuring tape to check mounting clearances
A. Determine which sensor for your pipe size,
A. The sensor connects to the module box with either a 10-foot or 30-foot
cable and the module box has a 4-foot power cable that must be plugged
into an electrical outlet.
B. Select a section of a straight pipe that is clean with no insulation, rust, or
seams. If there is insulation on the pipe, cut away a space slightly larger
then the sensor.
C. Look for a pipe that is horizontal or is vertical with an upward flow
D. There are two dierent types of brackets. FD-Q for smaller pipes and FD-R
for larger pipes.
Supported Pipe Diameter
Model EVOFQ038KIT EVOFQ075KIT EVOFQ125KIT EVOFQ200KIT
Outer Diameter (mm) Ø12 to Ø16 Ø16 to Ø18 Ø18 to Ø23 Ø23 to Ø28 Ø28 to Ø37 Ø37 to Ø44 Ø44 to Ø52 Ø52 to Ø64
NPS (Nominal Pipe Size) 1/4" 3/8" 1/2" 3/4" 1" 1-1/4" 1-1/2" 2"
DN (Diameter Nominal) 8 A 10 A 15 A 20 A 25 A 32 A 40 A 50 A
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Installation - Pipe Clamp-On Flow Sensor & Module (Cont'd)
3. Mounting EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT and EVOFQ200KIT
A. The brackets for FD-Q are designed to be used for two dierent pipe sizes.
The mount can be changed between the two pipe sizes by flipping the bracket
around as shown below. Ensure that the mount is set to the appropriate pipe
size..
B. Take o the mounting ring to expose and remove the four bracket mounting
screws.
C. Straddle the bracket on a clean section of the pipe. Make sure the bracket
is oriented is such a way that it is not on top of a horizontal pipe as this will
cause stability issues when the pipe is completely filled with fluid. Re-insert the
screws and tighten them evenly until the bracket is snug.
D. Slide the controller mounting
ring back on and carefully re-
place the controller within the
bracket with the display screen
upright and clearly visible.
E. Tighten the two screws evenly so the
controller is securely attached to the
bracket.
Evolution
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184 ■Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2022 Symmons Industries, Inc. ■symmons.com ■gethelp@symmons.com ■ZV-3700 REV 0 ■ 121322
EVOFQ038KIT, EVOFQ075KIT, EVOFQ125KIT,
EVOFQ200KIT
Installation - Pipe Clamp-On Flow Sensor & Module (Cont'd II)
4. Mounting Sensor Module
A. These modules have a 4-foot
power cord so find a location
that is within reach where the
box will be accessible and visi-
ble. The boxes are splash proof
but not waterproof so find a dry
place.
B. The modules can be mounted
by either screwing it into a wall
or but using cable ties to at-
tach them to an insulated pipe,
bracket, or hanger.
C. Plug the cable from the flow
sensor into the sensor module.
Once the connector is plugged
in, spinning the locking ring until
it locks into place.
4. Sensor Module App Setup
A. Scan Sensor Module QR Code
B. Complete App Steps

This manual suits for next models

3

Other Symmons Control Unit manuals

Symmons Maxline 8210CK Manual

Symmons

Symmons Maxline 8210CK Manual

Symmons Showeroff 4-420 Manual

Symmons

Symmons Showeroff 4-420 Manual

Symmons 2DIVBODYNSSRT Manual

Symmons

Symmons 2DIVBODYNSSRT Manual

Symmons Maxline 7-225 Series Manual

Symmons

Symmons Maxline 7-225 Series Manual

Symmons Temptrol VersaFlex S262BODY User manual

Symmons

Symmons Temptrol VersaFlex S262BODY User manual

Symmons LaundryMate LM600 Manual

Symmons

Symmons LaundryMate LM600 Manual

Symmons Temptrol 262BODY User manual

Symmons

Symmons Temptrol 262BODY User manual

Symmons Maxline 7-210-CK Manual

Symmons

Symmons Maxline 7-210-CK Manual

Symmons Temptrol S261BODY User manual

Symmons

Symmons Temptrol S261BODY User manual

Symmons LaundryMate LM600 Manual

Symmons

Symmons LaundryMate LM600 Manual

Symmons Temptrol 262XBODY User manual

Symmons

Symmons Temptrol 262XBODY User manual

Symmons Temptrol II Operation manual

Symmons

Symmons Temptrol II Operation manual

Symmons 7-210-CK Manual

Symmons

Symmons 7-210-CK Manual

Symmons 3DIVBODYSRT Manual

Symmons

Symmons 3DIVBODYSRT Manual

Symmons 7-102 Manual

Symmons

Symmons 7-102 Manual

Symmons 2DIV-BODY-NS Manual

Symmons

Symmons 2DIV-BODY-NS Manual

Popular Control Unit manuals by other brands

Kramer OSP SFP+ Technical notes

Kramer

Kramer OSP SFP+ Technical notes

Rain Bird HV Series installation instructions

Rain Bird

Rain Bird HV Series installation instructions

Datamax I-Class Installation and operating instructions

Datamax

Datamax I-Class Installation and operating instructions

GHL ProfiLux SMS-Module manual

GHL

GHL ProfiLux SMS-Module manual

Ultralife URB0001 user manual

Ultralife

Ultralife URB0001 user manual

MSI MS-3871 user guide

MSI

MSI MS-3871 user guide

Boge FOCUS operating instructions

Boge

Boge FOCUS operating instructions

Allen-Bradley C Series installation instructions

Allen-Bradley

Allen-Bradley C Series installation instructions

Velleman Velbus VMB4PD manual

Velleman

Velleman Velbus VMB4PD manual

Satel INT-VMG manual

Satel

Satel INT-VMG manual

ESBE ALF 4 Series manual

ESBE

ESBE ALF 4 Series manual

Unitech TB160 quick guide

Unitech

Unitech TB160 quick guide

Texas Instruments LP-MSPM0C1104 user guide

Texas Instruments

Texas Instruments LP-MSPM0C1104 user guide

Flo-Tite F300 Installation operation & maintenance

Flo-Tite

Flo-Tite F300 Installation operation & maintenance

Wilo PLR Installation and operating instructions

Wilo

Wilo PLR Installation and operating instructions

Assured Wireless AW12-HP user manual

Assured Wireless

Assured Wireless AW12-HP user manual

Jung MSC 1000 KNX operating instructions

Jung

Jung MSC 1000 KNX operating instructions

e-sylife Temperature Module Quick installation guide

e-sylife

e-sylife Temperature Module Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.