1. Composition & Specifications
2. Installation
3. Keypad Description
4. Functions & Initial Setting
4-1. General Functions
4-1-1. How to Enter General Functions
4-1-2. Vibration Setting
4-1-3. Buzzer Setting
4-2. Extended Functions
4-2-1. How to Enter Extended Functions
4-2-2. Setting Group Number & Channel Number
5. Display Description & Guest Pager Number Setting
5-1. Screen Display Description
5-2. Random Number Setting
5-2-1. Input a Random Number
★ 5-3. Fixed Number Setting
★ 5-3-1. Input the Fixed Number
6. How to Call the Guest Pagers
6-1. Make a Call
6-1-1. How to Call a Random Number
★ 6-1-2. How to Call the Fixed Number
6-2. Cancel the Call
7. Initialization
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
Picture
2
2
3
3
3
3
3
4
4
4
4
5
5
5
5
6
6
7
7
7
7
8
8

< Transmitter GP-1000T SET >
ManualAntenna Adapter
(DC 12V 1A)
Transmitter
(GP-1000T)
< Guest pager SET >
Charger Jump Cable
(Optional purchase)
Adapter
(AC 8V 3A)
Guest pager
4) Twist the antenna onto the connector located on the rear of the transmitter.
5) Plug-in the adapter and insert the connector into the ports next to the antenna.
6) Setting group & channel numbers to start using the system. (refer to 4-2., page4)
2. Installation
* Charging time : About 2.5 hours
* Standby time : About 9 hours
* Capacity of adapter : Recharging up to 20 guest pagers at once.
1. Composition & Specications
1) Stack up guest pagers on the charger. / Insert GP-200R into the charger.
2) Plug-in the adapter and insert the connector.
3) Make sure all pagers are fully charged and powered on.
GP-1000T
SET
Guest pager
SET
GP-100R, GP-101R GP-200R GP-300R
FM / 433MHz
Dipole Antenna / 300m
DC 12V / 1A
W130 × L170 × H32mm
410g
Graphic LCD
Transmitter (GP-1000T)
Frequency
Power
Battery
Dimension
Weight
Color
FM / 433MHz
AC 8V 3A
Lithium-polymer battery
¢95 × H17mm
86g
Red, Green, Black
FM / 433MHz
AC 8V 3A
Lithium-polymer battery
W53 x L105 x H11 mm
35g
Black
FM / 433MHz
AC 8V 3A
Lithium-polymer battery
W58 x L115 x H15 mm
72.5g
White&Blue
Frequency
Antena/Distance
Power
Size
Weight
Display

RC (Range Check)
Bt (Backlight Time)
Fn (Fix Number)
Ct (Call Time)
Mt (Motor)
Bu (Buzzer)
LE (LED)
Menu Initial Range Display Explanation
0 (off)
10s
0
30s
1 (on)
1 (on)
1 (on)
0-off, 1-on
0 ~ 99s (0:Duration)
0 ~ 9999 (0:Use a random number)
0 ~ 99s (0:Duration)
0-off, 1-on
0-off, 1-on
0-off, 1-on
rcon, rcof
-
0~9999
ct00~ct99
Hton, Htof
buon, buof
LEon, LEof
The function is used to alert staff and guests if
the guest pager is out of range area.
Operating time of backlight
Setting fixed number of guest pagers
Ringing time of guest pagers
Vibration on/off
Buzzer on/off
LED on/off
FUN
DEL
Press it longer
NEXT
Move to the desired function menu
4-1-1. How to Enter General Functions
4-1-2. Vibration Setting
4. Functions & Initial Setting
①F keys : F1~F4 keys correspond to the 1~4 in the display LCD
②FUN/DEL : Function / Delete
⑤NEXT
⑥CALL : Call / Enter
④ESC : Cancel / Exit
③Number keys : Press it longer convert to alphabet
F1 F2 F3 F4 FUN
DEL
1A2b3C4d5E
6F7H8L9P0U
CH ESC NEXT CALL
3. Keypad Description
4-1. General Functions
1
2
3
4
1
P1 GP2
N
Gn
1
Mt
-n
0 - off 1- on
1A
FUN
DEL
Press it longer
CALL
Save
ESC
Exit
NEXT
Move to [Mt]
×4

Gn (Group number)
Pn (Channel number)
Explanation
1
1
1 ~ 99
1 ~ 99
gn01 ~ gn99
Pn01 ~ Pn99
g01 ~ g99(GP-200R)
P01 ~ P99(GP-200R)
Identication number to avoid the interference
with the same products of surrounding users
FUN
DEL
Press it longer
FUN
DEL
Press it longer again Input the password
4-2-1. How to Enter Extended Functions
※For GP-200R, Gn/Pn indicates as g/p.
1
2
3
4
1
P1 GP2
N
Gn
-----
-n
95790
4-2-2. Setting Group Number & Channel Number
ex) Gn : 44, Pn : 33
※Group & Channel numbers can be set only once at rst.
Initalization is required when needs to change.
CALL
Save
NEXT
Move to [Pn]
CALL
Save
ESC
Exit
1
2
3
4
1
P1 GP2
N
Gn
44
Gn
-n
Input Group number
4d
1
2
3
4
44
P1 GP2
N
Gn
33
Pn
-n
Input Channel number
3C
4-2. Extended Functions ( * This menu is protected by password. )
CALL
Save
ESC
Exit
1
2
3
4
1
P1 GP2
N
Gn
1
Bu
-n
0 - off 1- on
1A
FUN
DEL
Press it longer
4-1-3. Buzzer Setting
NEXT
Move to [Bu]
×5
Initial Range DisplayMenu

CALL
Lo (Low battery)
rFEr
P
U_
「」, number
outr
ExplanationGuest pager display GP-200R display
When it receivers a call
Low battery, recharging is required
Faulty RF, No reception – Please contact us
% of remaining battery
Version information (ex. U-32)
When RF o, 「」and number will be ashed. Stack up the pager on the charger
Alerting when the guest pager is in out of range area.
It will be stopped when it is within the range.
5-1. Screen Display Description
Caution! The transmitter’s group & channel numbers and guest pagers’group & channel numbers
should be identical. Please stack up all guest pagers on the charger before setting.
Random Number Setting is able to allocate any numbers to each guest pager whenever it is used.
Advantage :using any numbers depending on the situation. (range: 1~9999)
5-2-1. Input a Random Number ▶[7P] 6-1-1. How to Call a Random Number
Caution) Although there is a number‘0’ or other number by Fn,
Please follow the instruction below from the beginning.
※The random number function is not usable when GP-1000T is in interactive transmission mode.
Please set the GP-1000T as simplex mode if you wish to use the random number function
- Refer to GP-1000T additional features.
5-2. Random Number Setting
FUN
DEL
Press it longer
NEXT
Move to [Fn]
Enter to General Functions
0
Rc
0
Fn
5. Display Description & Guest Pager Number Setting
CALL
Save
ESC
Exit
1
2
3
4
44
P33 GP2
N
Gn
0
Fn
-n
Input number ‘0’
0U
0
0
0
0
0
0
0
0
0
0
CAL
Lo
rFE
P
U_
「」, number
out

Fixed Number Setting is able to allocate guest pager’s numbers beforehand. (ex. 1~10 or 11~20)
Advantage :Simply call the preset number.
It does not need to allocate the number every time when it uses.
★5-3. Fixed Number Setting
FUN
DEL NEXT
Move to [Fn]
Enter to General Functions
0
Rc
0
Fn
★5-3-1. Input the Fixed Number ▶[7P] 6-1-2. How to Call the Fixed Number
ex) Preset the guest pager number 1 to 10
CALL
Enter
CALL
Proceed next number automatically
1
2
3
4
44
P33 GP2
N
Gn
1
Fn
-n
Input the starting number
1A
1
1
1
Separate the guest pager on top
2
2
2
Repeat this procedure until the last one
ESC
Exit
10
1
2
3
5
4
6
7
Place the guest pagers
in order
Press it longer
Separate the guest pager on top
Caution! The transmitter’s group & channel numbers and guest pagers’group & channel numbers
should be identical. Please stack up all guest pagers on the charger before setting.

★6-1-2. How to Call the Fixed Number
1
2
3
4
44
P33 GP2
N
Gn
1
-n
Input pager number
1A
1
6-1. Make a Call
6-1-1. How to Call a Random Number
CALL
Enter
1
2
3
4
44
P33 GP2
N
Gn
8
-n
Input a random number
8L
CALL
Call
1
2
3
4
8
44
P33 GP2
N
Gn
8
-n
Input pager number
8L
8
8
8
Separate the guest pager on top
Separate the guest pager on top
0
0
0
0
0
0
0
0
0
0
CALL
Call
10
9
8
7
5
6
4
3
2
1
Caution! All guest pagers should be stack up when input a number.
Maximum 4 digits (range: 1~9999, 3 digits for GP-200R)
Hand over to customer
Hand over to customer
Return the guest pager
Return the guest pager
6. How to Call the Guest Pagers

How 2
6-2. Cancel the Call
7. Initialization
Group & Channel numbers can be set only once at first.
Initialization is required when needs to set them again.
Initialization can be completed when group & channel numbers are identical.
ESC
Exit
1
2
3
Stack it up on the pager
10
9
8
7
5
6
4
3
2
1
Return the guest pager
1
2
3
4
1
44
P33 GP2
N
Gn
1
-n
Input the pager number
1A
FUN
DEL
Cancel
Press FUN/DEL key
FUN
DEL
How 1
Input code
1
2
3
4
44
P33 GP2
N
Gn
EFEF
-n
EFEF
Press it longer
convert to alphabet
5E6F
0
0
0
Initialization completed

Memo
9


■SYSCALL France - www.syscallglobal.fr
0033 (0)1 84 17 61 81 - [email protected]
242 boulevard de Stalingrad 94500 Champigny sur Marne,
France
■NTTWORKS CO., LTD
413-9 NTTWORKS Bldg, Galhyun-Dong, Eunpyong-Gu
Seoul, Korea
Manufacturer
This manual suits for next models
4
Table of contents
Other Syscall Pager manuals