manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. System air
  6. •
  7. Temperature Controllers
  8. •
  9. System air LCD display for SENSE User manual

System air LCD display for SENSE User manual

14:3311
0
°C
.
!
CO
2
OK
14:33
22
0
°C
.
11
0
°C
.
!
CO
2
OK
14:33
22
0
°C
.
11
0
°C
.
!
CO
2
OK
14:33
22 0
°C
.
11 0
°C
.
!
CO
2
OK
UP and DOWN keys are for selecting current manual
mode. You can select changesby pressing OK key.
LCD display for SENSE
Up key
Down key
Back
key
Menu/OK Outdoor
temperature
Extract
temperature
Status
bar
Operating
mode
HOME PAGE
STATUS BAR MANUAL MODE SCREEN
QUICK MENU
MAIN MENU
Time
16.5°C 22.0°C
21.3°C
-11.0°C
°C
!
CO
2
Outdoor air
temperature
Supply air
temperature
Extract air
temperature
Exhaust air
temperature
*Setpoint for Minimal, Medium and Nominal .
Display brightnes
settings
Night display settings:
Display dims in
the dark
Screen dims in
light darkness
Screen dims in
hard darkness
Turn off night mode
– screen is always
ON.
Boost function
activation
Selecting AUTO mode
(Time scheduler) or
Manual mode
Setting of Time
Schedule
Review and
acknowledge of alarms
Settings:
KEYBOARD LOCK
Keyboard lock disables operatoin of the keys and than prevents
unauthorized personel from changing settings.
Active alarm
(warning/fault)
Current status
ON/OFF
Keyboard locked
status
Active mode
AUTO/MANUAL
CO2Air quality indicator
While pressing button or you can scroll between modes.
2sek
!
!
CO2
CO2
Function is activated with pressing and
OK
for 2 seconds. In status bar is showed
simbol , Which mean keyboard is
locked. Operation of the keys is disabled.
For deactivation of function, again
simultaneously press
OK
and for 2 seconds.
In settings, it is possible to turn automatic
key lock after 15 minutes (min. 2 min –
max. 2h) of inactivity.
!
Night display
settings
Lock/Unlock
keyboard
System info
Setpoint settings for temperature
Time settings
Date settings
Lor
Entering of Quick menu is
done with the key . Key
is for selecting between
Temperature view and Alarm
screen. With k
OK
ey Home
menu is availlable.
i
1
14:33
22
0
°C
.
11
0
°C
.
!
CO
2
OK
OK
SYNCHRONIZATION
FIRST START
CHANGE OF MODBUS ADDRESS
SYSTEM ALARMS
Switch off power supply
by switching main swith
on the SENSE unit.
System synchronization.
Wait few seconds...
When synchronization is finished,
HMI is ready to use.
Switch on power supply
on the SENSE unit.
Enter menu for change of modbuss address
On first start, when HMI is
connected with controller,
display for changeing
Modbus address of the HMI is
displayed.
With keys and
select Modbus address of HMI. With key
acknowledge selection.
8sek
In menu for changing of Modbuss address is possible to enter in first
minute while HMI is powered. By simunltaneously pressing two keys
and for 8 second, you will enter menu.
S01 – Error in data connection between controller and HMI. Check if the data cable is correctly
connected to the connector on SENSE unit and HMI. When the cause of the error is removed,
the error is automatically acknowledged.
S02 – Touch screen error. In the case of this error, HMI or controller must be serviced.
Only trained personnel is authorized to
operate with main switch.
Factory set is 2.
LCD display for SENSE
First start
1
14:33
22
0
°C
.
11
0
°C
.
!
CO
2
OK
OK
OK
SETTING OF MODBUS ADDRESS
!
!
S01

Other System air Temperature Controllers manuals

System air TCA 150D User manual

System air

System air TCA 150D User manual

System air NTC10k User manual

System air

System air NTC10k User manual

Popular Temperature Controllers manuals by other brands

Yatai NTT-2000 user manual

Yatai

Yatai NTT-2000 user manual

Vertex VD 26 Series user manual

Vertex

Vertex VD 26 Series user manual

Sub-Zero SZ-7510-P-DI operating instructions

Sub-Zero

Sub-Zero SZ-7510-P-DI operating instructions

INSBUD IB-TRON 1000 GWC user guide

INSBUD

INSBUD IB-TRON 1000 GWC user guide

LaserLiner ThermoSensor Clamp operating instructions

LaserLiner

LaserLiner ThermoSensor Clamp operating instructions

iNels RFTC-10/G manual

iNels

iNels RFTC-10/G manual

Sorel TC Installation and operating instructions

Sorel

Sorel TC Installation and operating instructions

MULTISPAN UTC-320 manual

MULTISPAN

MULTISPAN UTC-320 manual

Chauvin Arnox Statop 4849 user manual

Chauvin Arnox

Chauvin Arnox Statop 4849 user manual

Lennox A122C user manual

Lennox

Lennox A122C user manual

Temptek VETERAN LS Series instruction manual

Temptek

Temptek VETERAN LS Series instruction manual

Simply Aquaria TC225 Instruction guide

Simply Aquaria

Simply Aquaria TC225 Instruction guide

M-system TC10EM instruction manual

M-system

M-system TC10EM instruction manual

Omron E5AN Communications manual

Omron

Omron E5AN Communications manual

i-therm Px-418e User's operating manual

i-therm

i-therm Px-418e User's operating manual

Uponor c56 Installation and operation manual

Uponor

Uponor c56 Installation and operation manual

S+S Regeltechnik HYGRASGARD FSFTM-Modbus Operating Instructions, Mounting & Installation

S+S Regeltechnik

S+S Regeltechnik HYGRASGARD FSFTM-Modbus Operating Instructions, Mounting & Installation

Danfoss ECL Comfort 100M User's guide and installation instructions

Danfoss

Danfoss ECL Comfort 100M User's guide and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.