TAGHeuer Timing Page 5 / 8
5. Printer Configuration
The printer incorporates a number of configurable option, each of which has a number of setting.
5.1. To change the setting of any option, follow the procedure below:
1) Ensure the printer is OFF
2) Press and hold the Mode Button: 5 seconds. The Status light will flash 5 times to show that the
printer is in configuration mode. Release the Mode button
3) Press the Mode button the same number of time as the option that you wish to change
4) After a short delay, the Status Light will flash the same number of times as the option that you
have chosen. If you have made a mistake at this stage, simply wait: after a delay, the printer will
power-on without changing any options.
5) To proceed with configuration, press the Mode button the same number of time as the setting that
you wish to make
6) After a short delay, the Status light will flash the same number of times as the setting that you
have made
7) After a further delay, the printer will power ON with the new setting
Option Description Setting n° Setting
1 RS232 Protocole Request specific to TAG Heuer Timing
2 RS232 Baud Rate 1115200
257600
419200
59600
72400
Other Under request at TAG Heuer Timing
3 Flow Control Under request at TAG Heuer Timing
4 Font 1Arial 16 (24 characters / line)
2Arial 12 (32 characters / line)
3Arial 9 (42 characters / line)
4Arial 8 (48 characters / line)
5 Character Format 1Normal
2Double Width
3Double Height
4Double Width and Height
6 Print Denstity 1Lowest
4Highest
7 Printer Currint 1Highest
4Lowest
8 Print Format 1Standard paper, normal printing
2Standard paper, upside down printing
3Labels, Normal printing
4Labels, upside down printing
9 Sleep/Wake up 1Never sleeps
2Off after 1 minutes
3Off after 2 minutes
4Off after 5 minutes
5Off after 10 minutes