TALOS C730 User manual

BOLLARD WITH RETRACTABLE OIL-HYDRAULICALLY
DRIVEN CYLINDER
EN 13241
EN 12453
EN 12445
C730
GB Instructions manual pages 1 - 20
the gate opener

2
English
C730
INTRODUCTION
This operator is designed for a specic scope of applications as
indicated in this manual, including safety, control and signaling
accessories as minimum required with FADINI equipment. □
Any applications not explicitly included in this manual may
cause operation problems or damages to properties and
people. □Meccanica Fadini snc is not liable for damages
caused by the incorrect use of the equipment, or for
applications not included in this manual or for malfunctioning
resulting from the use of materials or accessories not
recommended by the manufacturer. □The manufacturer
reserves the right to make changes to its products without
prior notice. □All that is not explicitly indicated in this manual
is to be considered not allowed.
BEFORE INSTALLATION
Before commencing operator installation assess the suitability
of the access, its general condition and the structure. □Make
sure that there is no risk of impact, crushing, shearing,
conveying, cutting, entangling and lifting situations, which
may prejudice people safety. □Do not install near any source of
heat and avoid contacts with ammable substances. □Keep all
the accessories able to turn on the operator (transmitters,
proximity readers, key-switches, etc) out of the reach of the
children. □Transit trough the access only with stationary
operator. □Do not allow children and/or people to stand in the
proximity of a working operator. □To ensure safety in the
whole movement area of a gate it is advisable to install
photocells, sensitive edges, magnetic loops and detectors. □
Use yellow-black strips or proper signals to identify dangerous
spots. □Before cleaning and maintenance operations,
disconnect the appliance from the mains by switching o the
master switch. □If removing the actuator, do not cut the
electric wires, but disconnect them from theterminal box by
loosening the screws inside the junction box.
INSTALLATION
All installation operations must be performed by a qualied
technician, in observance of the Machinery Directive
2006/42/CE and safety regulations EN 12453 - EN 12445. □
Verify the presence of a thermal-magnetic circuit breaker 0,03
A - 230 V - 50 Hz upstream the installation. □Use appropriate
objects to test the correct functionality of the safety
accessories, such as photocells, sensitive edges, etc. □Carry out
a risk analysis by means of appropriate instruments measuring
the crushing and impact force of the main opening and closing
edge in compliance with EN 12445. □Identify the appropriate
solution necessary to eliminate and reduce such risks. □In case
where the gate to automate is equipped with a pedestrian
entrance, it is appropriate to prepare the system in such a way
to prohibit the operation of the engine when the pedestrian
entrance is used. □Apply safety nameplates with CE marking
on the gate warning about the presence of an automated
installation. □The installer must inform and instruct the end
user about the proper use of the system by releasing him a
technical dossier, including: layout and components of the
installation, risk analysis, verication of safety accessories,
verication of impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
The end-user is required to read carefully and to receive
information concerning only the operation of the installation
so that he becomes himself responsible for the correct use of it.
□The end-user shall establish a written maintenance contract
with the installer/maintenance technician (on -call). □Any
maintenance operation must be done by qualied technicians.
□Keep these instructions carefully.
WARNINGS FOR THE CORRECT OPERATION OF THE
INSTALLATION
For optimum performance of system over time according to
safety regulations, it is necessary to perform proper
maintenance and monitoring of the entire installation: the
automation, the electronic equipment and the cables
connected to these. □The entire installation must be carried
out by qualied technical personnel, lling in the Maintenance
Manual indicated in the Safety Regulation Book (to be
requested or downloaded from the site
www.fadini.net/supporto/downloads).
□Operator: maintenance inspection at least every 6 months,
while for the electronic equipment and safety systems an
inspection at least once every month is required. □The
manufacturer, Meccanica Fadini snc, is not responsible for
non-observance of good installation practice and incorrect
maintenance of the installation.
DISPOSAL OF MATERIAL
Dispose properly of the packaging materials such as
cardboard, nylon, polystyrene etc. through specializing
companies (after verication of the regulations in force at the
place of installation in the eld of waste disposal). Disposal of
electrical and electronic materials: to remove and dispose
through specializing companies, as per Directive 2012/19/UE.
Disposal of substances hazardous for the environment is
prohibited.
GENERAL WARNINGS FOR PEOPLE SAFETY
anti-terrorism oil-hydraulic automatic bollard

GENERAL DESCRIPTION OF THE PRODUCT
Talos C730 is designed for trac control. The bollard can fully retract into the ground, at with road or street level. Moviments are
by an incorporated oil-hydraulic motor-pump. With the bollard in standing position, trac is securely stopped from the area.
Certied and tested in compliance with:
- ASTM F2656-18A C730
- PAS 68:2013 V/7500 (N3)/48
- IWA 14-1:2013 V/7200 [N3C]/48
Designed and constructed to comply with ASTM/PAS 68 requirements (K4/M30/C730 a 7,5 t vehicle at 48 km/h). To this purpose,
the foundation casing incorporates some specic, structural component parts meeting these standards.
Suitable for heavy duty applications and protection of accesses to sensitive areas (anti-terrorism) such as military bases,
embassies, banks, ministerial entities, etc.
The post has a diameter of 275 mm and a thickness of 12 mm (S355J2H steel), cataphoresis treated and polyester powder coated.
With the bollard in standing position, the part of the post remaining inside the casing into the dedicated guide is 40 cm
(constraint). A greater resistance to impact and breakout is so ensured.
The Elpro S40/S20 electronic controller is to be installed on the outside, in a protected place.
The bollard is designed to take a number of accessories to ensure such a level of safety and functionality allowing the entire
automatic system to be suitable for any applications in public and private areas.
TALOS C730 can be required, at the time of the order, to be delivered with supplementary accessories (all the accessories are
pre-assembled and connected to the internal terminal board):
•Beeper: an acoustic device emitting an intermittent sound during the rising and lowering movements of the bollard.
• Heater: a device to keep warm the inside of TALOS C730 when the external temperature is lower than 5 °C.
Colour customizing available in any RAL options, polyester powder coating.
It comes along with the following screws:
• 2 nos. M16 bolts with lifting rings
• 4 nos. M16 TEI screws
• 8 nos. M16 TE screws
English
3
C730 anti-terrorism oil-hydraulic automatic bollard
Meccanica Fadini s.n.c.
Director in charge
CE DECLARATION OF CONFORMITY of the manufacturer:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under its own responsibility that TALOS C730
is in compliance with the Machinery Directive 2006/42/CE, moreover: it is to be sold and installed as a comprehensive
“Automatic System”, including the accessories and components as recommended by the Manufacturing Company. In
observance of the current directives, any automatic system is to be regarded as a“machine”. Therefore it is required that all
the applicable safety norms be strictly complied with by the installation agents, who are also required to issue a
Declaration of Conformity of their own. The manufacturing company is not liable for incorrect applications or misuse of its
products that are declared to be produced in compliance with the following norms: EN 12445 & EN 12453 ie. analysis of the
risk and actions to cure them , Low Voltage Directive 2014/35/UE, Electro-magnetic Compatibility Directive 2014/30/UE.
In order to certify the product, the Manufacturer declares under own responsibility the compliance with the PRODUCT
NORMS EN 13241-1.

NON MANDATORY RUNNING TEST (not required for installation purposes)
Talos C730 is factory-tested to assess correct functioning in normal conditions before being sent out to customers.
Anyway, for the installer to be able to carry out some testing before installation, it is possible to access the inner terminal block for
the electrical connections by removing the hatch cover: unscrew the two lateral screws of the cover and pull out the junction box
along with the connector.
NOTE WELL: once testing is nished, put back the box and the cover.
MAIN COMPONENTS
Post cover with
rubber edge and with N. 12
warning LEDs, ashing light
amber colour
Type approved, retro-
reecting sticker
Hatch allowing connec-
tion of the electric cable
from the electronic
controller
Cover
plate
Casing to embed
in cement
Ø 275 mm, retractable
cylinder
1.000 mm height,
12 mm thickness
Pic. 1
Pic. 2
Junction
box with
connector
Open the
connector
and carry out
the connections
as indicated
in pic. 19 page 13
M16
English
4
1.0001.510 mm
C730 anti-terrorism oil-hydraulic automatic bollard
!

English
C730
REMOVING THE BOLLARD FROM THE CASING
Pic. 3
Remove the M16 screws from the
rectangular cover plate
Remove the inner xing plate
Drive the two M16 screws with lifting
rings into the dedicated holes
By means of a winch, carefully hoist the
inner assembly of the bollard, and mind
not to tear o or damage the oil pipes
and the inner electrical cables
M16 M16
M16
Casing to
cement
NOTE WELL: before
hoisting, disconnect
the ground cable
from the casing
M16
M8
M8
1)
3) 4)
5)
2)
8 x M16 screws
Remove the rectangular cover plate
5
anti-terrorism oil-hydraulic automatic bollard
!!

English
C730
!
!
M16
CEMENTING THE CASING
Dig a pit in the ground following the dimensions indicated in pic. 4.
Ø 50 mm
Elpro S40/S20
Pic. 4
Pic. 5
Check soil natural permeability: 50 liters of water must be able to soak away in not
longer than 30/40 minutes. If not, provide a pipe allowing rain water to ow into a
sewerage system or a collecting well equipped with a submersed pump to keep it
empty.
Lay a Ø 50 mm corrugated tube to lead the electric cables through it, either from a junction pit or directly from the Elpro S40/S20
electronic controller (pic. 5).
NOTE WELL: the foundation casing is to be set
perfectly levelled, and the upper edge must be 1-2 cm
higher than pavement surface (walking level)
Soakaway pebbles
Inlet (from below) of the
Ø 50 mm tube leading
the electric cables
Fit the two M16 lifting rings diagonally
across the casing to allow proper hoisting
and positioning
2 m2 m
INNER SIDE TO BE PROTECTEDEXTERNAL SIDE
=
100 cm
Road surface.
Walking level
=
0.0
0.0
Soakaway pebbles
7,5 cm 7,5 cm
~ 1,7 m
=
93 cm
107 cm
=
6
anti-terrorism oil-hydraulic automatic bollard
A
submersed
pump may
be needed
20 cm
approx.
!!
~ 1,7 m
0.0

English
7
anti-terrorism oil-hydraulic automatic bollard
C730
1 2
3 4
Pic. 7
Pic. 6
Iron armature: class B450C (ASTM A615 Grade 60) made of rebars whose
yield point is ≥ 450 MPa and breaking point ≥ 540 MPa.
A1 = n° 1 pc
n° 26 pcs
1.200 mm
ø 10
n° 22 pcs
1.000
ø 10
ø 10 - n° 9 pcs
ø 10 - n° 6 pcs
200
400
400
n° 12 pcs
ø 10
200
60 kg
A2
A1
B
B
275 330
!
400
n° 12 pcs
ø 10
300
1.200 mm
ø 10 - n° 4 pcs
1.200 mm

8
anti-terrorism oil-hydraulic automatic bollard
C730
English
1 2
1 2
= n° 2 pcs
B
ø 10 - n° 6 pcs
300
400
3 4
Pic. 8
A2 = n° 1 pc
ø 10 - n° 6 pcs
200
400
ø 10 - n° 3 pcs
1.200 mm
70 70
ø 10 - n° 9 pcs
275 330
1.200 mm

English
9
anti-terrorism oil-hydraulic automatic bollard
C730
3 4
ø 10 - n° 1 pc
1.200 mm
ø 10 - n° 4 pcs
1.000 mm
ø 10 - n° 6 pcs
1.000 mm
ø 10 - n° 2 pcs
1.000 mm
150150
A2
A1
B
B
Pic. 9
Pic. 11
Pic. 10

anti-terrorism oil-hydraulic automatic bollard
C730
English
C730
10
The upper level of the foundation casing must be 1-2 cm higher than the walking level in order to limit the
amount of rain water that can get inside.
Pour A-class concrete all around the casing up to approx 5-10 cm below the walking level. Wait all the time
required for the concrete to set rmly (at least 7 days) and then nish the surface work.
It is most important that the casing be1-2 cm higher than the area nished level. In no way Talos C730 is to
become a water gathering basin.
Avoid areas where soil tends to sag to prevent the bollard from staying ooded. In case of snow, the at
surface of the cover plate can be easily cleared even by heavy machanical means.
Pic. 12
~ 1,1 m
~ 1,4 m
!
!
!
!
!
!
The bollard must be positioned and perfectly levelled
before concrete is poured all around the foundation cage.
Iron armature:
class B450C (ASTM A615 Grade 60) made of rebars whose yield
point is ≥ 450 MPa and breaking point ≥ 540 MPa.
Concrete specications: A- Class C25/30, aggregate type 10-30
and Rck ≥ 30 N/mm² in compliance with UNI EN 12620.
Concrete volume: 1,3 m³
Soil: compaction index 90%, as per "Proctor" Test optimal curve,
in compliance with UNI EN 13286-2:2005.
Concrete: to set for at least 7 days before the installation of the
bollard can be carried on.
~ 1,4 m
~ 1 m
1-2 cm
7,5 cm
Ø 50 mm
0.0
Soakaway
pebbles
Concrete
Asphalt
~ 1,1 m
a submersed
pump may be
needed
!

Multipole cable
and ground cable
Elpro S40/S20
ELECTRIC CONNECTIONS TO THE ELECTRONIC CONTROLLER ELPRO S40/S20
The electronic controller Elpro S40/S20 is to be installed in a dry and protected place to prevent unauthorized actions.
Make sure that all the electric cables of the command and safety accessories are properly led to the controller.
Through the previously laid corrugated tube pull a multicore cable, type BUT FLESSIBILE FG 7OR 12x1,5 mm²
(not supplied
with the equipment, but available on request as per catalogue) for the electrical connections to the Elpro S40/S20 controller,
depending on which model of TALOS C730 is to be installed (see page 18, point 9).
NOTE WELL: lay a ground cable to suit the type of installation required, either public or private, in compliance with the
existing safety norms. Connect it inside by the provided screw.
Pic. 13
IP 66
The multicore cable BUT FLESSIBILE FG 7OR 12x1,5 mm² (see page 18, point 9) must not exceed
30 m of length.
Lay the ground cable in compliance with the installation requirements, section as suitable. Pic. 14
INSTALLATION OF THE BOLLARD
Once made sure that concrete has rmly set around the casing, insert the inner assembly. Eventually remove the lifting rings.
By a winch hoist and insert the inner assembly
into the casing, minding not to tear, cut or
somehow damage the pipes and the internal
electric cables
They must be at
the same level
NOTE WELL: MAKE SURE THE ENTIRE INNER ASSEMBLY FITS
WELL INTO ITS SEAT. THE PLATE, ON WHICH THE
MOTOR-PUMP IS FIXED, MUST PROPERLY REST ON THE
CASING INNER SURFACE, CLEARED OF POSSIBLE CHIPS.
The parts must
perfectly t into the
dedicated seat of the
ground casing
!
!
!
English
11
anti-terrorism oil-hydraulic automatic bollard
C730

A watertight junction box is incorporated in the bollard with all the electrical connections to the bollard (electric motor, limit
switches, LED lights and beeper as an option). Remove the connector from the box and make the connections to the respective
terminals using a multicore cable (not provided with the equipment).
Pic. 15
Junction box with
connector
asher and/
or beeper
PCB
“Heater for
Talos series”
(if mounted)
LED lights
motor
common
LEDs and/or beeper common
motor live
(Pic. 19) [B]
motor live
(Pic. 19) [B]
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
53
51
17
16
52
18
NOTE WELL: TIGHTEN THE CABLE GLAND
PROPERLY BEFORE FITTING BACK THE
CONNECTOR, OTHERWISE INFILTRACTION
PROTECTION GRADE CANNOT BE GUARANTEED.
IP 66
Connections to the terminals of Elpro S40/S20 controller
(see the instructions included with this accessory)
Pic. 16
NOTE WELL: before carrying on with the electrical connections, it is advisable to identify which optional
accessories are mounted on TALOS C730 (beeper or heating device), and so be able to establish which
connections are to be made to the connector.
Beeper
inside
the bollard
Beeper Heater
Heating device
inside the
casing
!
!
!
12
11
56 ground limit switch
blue and gray cables - green wires
limit switch opening
gray cable - white wire
(Pic. 18) [A]
limit switch closing
blue cable - white wire (Pic. 18) [A]
55 limit switch +24 Vdc
blue and gray cables - brown wires
English
anti-terrorism oil-hydraulic automatic bollard
C730C730
12
IP 66
NOTE WELL: a 40 μF capacitor is pre-wired inside the junction box.
An additional 20 μF capacitor is required to be connected to terminals A and B of Elpro S40/S20.

FIRST RUN TEST
Pic. 17
NC
230 V
NOTE WELL: power supply the system only after all
the electrical connections are made.
Once completed the connections of all the safety (all NC contacts of Elpro
S40/S20 controller must be closed) and command accessories to the respective
terminals in Elpro S40/S20, the rst run test can be performed.
A careful analysis of possible hazards is always recommended to be executed
before this test.
If a radio transmitter is available, after having match encoded it with the
receiver following the instructions provided with it, pulse once for the bollard to
rise.
[A] Check the electrical connections to the limit switches. Supply voltage and check the status indication LEDs rst of all:
with the bollard in down position the L8 LED is OFF, while the L9 LED is ON. If not, swap the connections to terminals 11
and 12 in Elpro S40/S20.
If the installation consists of more than one bollard carry on the same procedure for each of them
L8 = M1 opening limit switch, normally ON, o with the bollard in down position
L9 = M1 closing limit switch, normally ON, o with the bollard in standing position
NOTE WELL: the bollard is required to be fully down.
On installation phase should the bollard go up, even partially, proceed with
the manual release and bring it fully down on to the bollard stop (Pic. 22).
Close all NC
contacts to
Elpro S40/S20
controller
Pic. 18
Connections to the electric motor of
the hydraulic motor pump
Bollard in standing position:
no access allowed
1st pulse
[B] Once supplied the system with electric power, and made sure the LEDs of the limit switches are ON as indicated (bollard
down, L8 LED must be OFF), the bollard should rise when a command pulse is given. Should it not, switch o power supply and
reverse the live connections to the motor in Elpro S40/S20.
If the installation consists of more than one bollard carry on the same procedure for each of them
common
common
13
Pic. 19
!
!
!
55 56 55 56
English
anti-terrorism oil-hydraulic automatic bollard
C730
NOTE WELL: a 40 μF capacitor is pre-wired inside the junction box.
An additional 20 μF capacitor is required to be connected to terminals A and B of Elpro S40/S20.

FIXING THE COVER PLATES OF THE BOLLARD
Pic. 21
Pic. 20
M16
IMPORTANT: IT IS RECOMMENDED
THAT ALL OF THE FIXING SCREWS
BE GREASED
IMPORTANT: BOLLARD AND COVER PLATE ARE TO BE
PERFECTLY CENTERED, SO THAT THE GAP BETWEEN
BOLLARD AND COVER PLATE HOLE IS EQUALLY SPACED
ALL AROUND
The cover plate is to rmly rest all over the
surface and closely adhere to the circular ange
around the post
M16
GREASE
!
!
anti-terrorism oil-hydraulic automatic bollard
C730
English
C730
14

15
anti-terrorism oil-hydraulic automatic bollard
C730
English
MANUAL RELEASE OF THE BOLLARD AND LOWERING OPERATIONS (IN CASE OF AN EMERGENCY)
In case of an electric power failure the bollard system is congured to stay in standing position.
For the bollard to be allowed to descend, it is required that it is on voltage.
It is possible though, in particular situations of danger and/or emergency, to lower the bollard manually as follows:
• Remove the xing screws and take o the aluminium cover.
• Insert the release spanner through the cover hole to t it into the triangular prole of the lock and turn it one complete turn
anti-clockwise.
IMPORTANT: once the bollard is fully down, turn the spanner clockwise and tighten hard.
Pic. 22
IMPORTANT: with the bollard in fully
down position, tighten hard clockwise
by the release spanner.
!

16
anti-terrorism oil-hydraulic automatic bollard
C730
English

17
anti-terrorism oil-hydraulic automatic bollard
C730
English
give to the end-user of the installation
MAINTENANCE RECORD
hand over to the end user of the installation
Installation address:
Installation type:
Sliding gate
Over-head door
N°
1
2
3
4
5
6
Service date
Stamp and signature
installation technician/maintainer
Signed for acceptance
end user
buyer
Technical maintainer End user/sService description
Lateral folding
door
Swinging gate
Folding door
Bollard
.............................
Road barrier
Operator model:
Dimensions per gate leaf:
Weight per gate leaf: Installation date:
Quantity of models
installed:
Maintainer: Date:
NOTE WELL: this document must record any ordinary and extraordinary services including installation, maintenance,
repairs and replacements to be made only by using Fadini original spare parts.
This document, for the data included in it, must be made available to authorized inspectors/ocers, and a copy of it must
be handed over the end user/s.
The installer/maintainer are liable for the functionalities and safety features of the installation only if maintenance is
carried on by qualied technical people appointed by themselves and agreed upon with the end user/s.
X
the gate opener

English
18
anti-terrorism oil-hydraulic automatic bollard
C730
INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM
1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by qualied and authorized
technicians in compliance with the existing regulations (www.fadini.net/supporto/download).
2) This automatic system is intended to be exclusively used for the applications described in this manual and includes the
minimum of safety, command and signalling accessories as required to comply.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Providing a suitable reinforcement metallic framework ensures that the breakout resistance value be respected as stated
in this manual. NOTE: the iron framework (all of the steel rebars) is not supplied by our company. It has to be made locally in
compliance with the technical data, drawings and all of the indications described in this installation manual. The
components of the structure developed in this way are able to make the most of the performance features of each
component and ensure the impact resistance features of the bollard as indicated.
5) Make sure the soil be adequate to take the bollard to avoid that settling at a later stage causes problems to the system.
6) Make sure the site be free from utilities that may interfere with the installation.
7) Make sure that electromagnetic sources be at a suitable distance from the accessories, especially from the loop detectors.
The magnetic elds of other sources may aect the detection of the loops as well as those of other command and safety
devices of the system.
8) Make sure the power supply to the electric motor be 230 V (50 Hz).
9) Recommended power supply cable:
BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 30 metres max): for TALOS C730 (in both versions, the standard one and the
one tted with heating device).
N.W. The beeper, either tted to TALOS C730 or not, is irrelevant to the choice of the cable.
The section of the cable to ground is to comply with the site regulations.
10) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
11) The installer shall provide the nal user with information related to all of the operating commands and functions of the
system, including manual lowering of the bollard in case of an emergency (manual release operation).
12) The installer shall inform the nal user of the dangers coming from the presence of persons , especially children, in the
proximity of the bollard.
13) The manufacturer reserves the right to change this manual without previous notice.
As far as conguration and execution of the system are concerned, these are to comply with the laws in the country of
installation.
Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not
indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of materials
or accessories not approved by the company itself. It is to be noted that the product respects the impact and
breakout resistance values as indicated provided that the installation of the same is carried out in
observance of the specications included in this manual of instructions. Various factors are to be carefully
taken into consideration such as compaction index, soil permeability coecient, concrete type, which may
aect the indicated values even signicantly.
This symbol indicates that a particular attention is required on the installation phases and on running the
operator. Failure to observe these indications may cause incorrect functioning of the bollard.
!
!
!
OPERATIONS FOR ORDINARY ROUTINE MAINTENANCE OF FADINI AUTOMATIC BOLLARDS (EVERY SIX MONTHS)
The standard maintenance routine sequence is as follows:
• Clean the ground cylinder and suck all material settlements.
• Clean water drains located at the bottom of the ground cylinder and/or excavation pit.
• Check any possible oil leaking from the hydraulic piston and, in case, x it.
• Overhaul the screws fastening the bollard to the ground cylinder, making sure they are properly tightened and lubricated.
• Check the oil-hydraulic motor-pump and oil pressure by assessing the rising times of the bollard. If required, top up oil in the
reservoir and/or parallel add an extra capacitor to the existing one (instructions manual is to be referred to).
• Check the correct functioning of the signal LED lights (if incorporated) in the bollard head.
• Sight check the electronic board controlling the bollard/s (e.g.: “ooded” relay contacts, oxidized terminal clamps, etc.).
• Check the correct functioning and positioning of the limit switches.
• Check the release system for bollard manual operations.
• Clean and recondition the rising cylinder if required, e.g.: paint patching up, replacing the back reecting sticker and /or the
cover tted with rubber edge.
IF OPTIONAL ACCESSORIES ARE INCLUDED, FURTHER MAINTENANCE IS REQUIRED AS FOLLOWS:
• Check the correct functioning of the safety accessories such as the inductive loop/s and the photocells.
• Check the correct functioning of the radio receiver and all of the remote controls.
• Check the correct functioning of the beeper.
• Check the correct functioning of the trac lights and the respective control card.

anti-terrorism oil-hydraulic automatic bollard
C730
19
English

English
Via Mantova, 177/A - 37053 Cerea (VR) Italy
Ph. +39 0442 330422 Fax +39 0442 331054
TECHNICAL DATA
ELECTRIC MOTOR
Absorbed power 2.200 W
Power supply 230 V
Frequency 50 Hz
Rated current 6 A
Maximum current 12 A
Intermittent service S3
Capacitor 40 μF
HYDRAULIC MOTOR PUMP TUNIT 3.20LP
Pump type P20
Working pressure 1 MPa (10 bar)
Working temperature -20 °C +80 °C
Oil type Fadini oil - code 708L
Reservoir capacity 3 liters
Protection grade IP 67
BOLLARD
Post diameter Ø 275 mm
Post thickness 12 mm
Post height 1.000 mm
Post nish polyester powder coating RAL 7016
Post material S355J2H steel
Ground casing hot dip galvanized
Piston diameter 30 mm
Shaft diameter 16 mm
Piston stroke 1.010 mm
Factory set thrust power 61 daN (61 kg)
Frequency of use very intensive (3.000 cicles/day)
Led power adaptor in: 230 V - 50 Hz out: 12 Vdc 600 mA
Led top lights 12 Vdc
Impact resistance 150.000 J
Breakout resistance 700.000 J
Max. static load 20.000 kg
Weight with casing 360 kg
Environment working temperature -20 °C +80 °C
Environment working temperature
with heating device -40 °C + 80 °C
Rising time [speed] ~ 5,50 s [18 cm/s]
Lowering time [speed] ~ 4,10 s [23 cm/s]
24
52
43
93
2.100 7.500
SPEED of vehicle (km/h)
150.000 J
700.000 J
MASS
of vehicle (kg)
Various factors, such as the compaction index, soil
permeability coecient and kind of concrete may reduce the
values indicated in the diagram even signicantly.
475
570
400
475
575
Ø 275
1.000
1.510 mm
anti-terrorism oil-hydraulic automatic bollard
2020/02
PRODUCT SPECIFICATIONS
Fully retractable automatic bollard for very heavy duty applications, made up of an incorporated oil-hydraulic motor pump unit
and an oil-hydraulic actuator inside the moving cylinder. Designed in compliance with ASTM/PAS 68 K4/M30/C730 specications
(vehicle of 7,5 t at a speed of 48 km/h). Suitable for access protection to sites under attack risk (anti terror) such as military bases,
embassies, banks, government institutions, etc. IP67. The height of the rising cylinder (from ground) is 1.000 mm. Rising cylinder
made of S355J2H steel, thickness 12 mm, cataphoresis treated and powder coated. AISI 304 brushed stainless steel cover sleeve
available for the rising cylinder. Rubber ring on rising cylinder head. Cataphoresis treated aluminium cover, nished to provide a
slip-proof treading surface. Rising cylinder tted with high intensity, microprismatic, retroreecting approved sticker (h 80 mm),
and 12 signalling LEDs with ashing light all around the top. Frequency of use 3.000 cycles/day. Hot dip galvanized steel casing
for ground foundation. Impact resistance 150.000 J, breakout resistance 700.000 J. Static load max 1.500 kg in standing position,
max 20.000 kg in lowered position. Working temperature -40 °C +80 °C. Supply voltage 230 Vac ± 10%, 50 Hz. Absorbed power
2.200 W. Connector and junction box IP 66 for cabling. Rising time ~ 5,50 s. Hydraulic device locking the bollard in standing
position.
C730
GB 2012/19/UE Directive
Re. disposal of electric
and electronic waste
DISPOSE PROPERLY OF MATERIALS
ARMFUL TO THE ENVIRONMENT
Table of contents
Popular Protection Device manuals by other brands

OBO Bettermann
OBO Bettermann isCon PR 90 SW Mounting instructions

Trylon
Trylon COUGAR INSTALLATION DRAWINGS & INSTRUCTIONS

Eaton
Eaton SPD160480D3M instruction manual

GE
GE D30 series instruction manual

Siemens
Siemens Cerberus Pyrotronics CP2341 installation instructions

GE
GE UR F35 Series instruction manual

ABB
ABB Relion 670 Series REL670 Commissioning manual

Fiessler
Fiessler AKAS LC-II M operating instructions

Ansell
Ansell HYLITE 47-402 Instructions for use

Arcteq
Arcteq AQ-F215 instruction manual

Scorpion Power System
Scorpion Power System Tribunus 06-120A ESC user guide

Respirex
Respirex workMaster HAZMAX User information