Tamarack Solar UNI-SP/01A User manual

info@
tamaracksolar.com
|
(800)
819
-
7236
1
Installation
Manual
UNI-SP/01A
Installation Manual
2021 Edition
UNI-SP01A Manual v3
For model:
UNI-SP/01A

Installation
Manual
UNI-SP/01A
support
@tamaracksolar.com 1
-
800
-
819
-
7236
Ext 556
Page
1
Bolt Size Dry Lubricated
1\4-20 6 \ (75) 5 \ (64)
5\16-18 11 \ (132) 9 \ (112)
18-8 Stainless
Torque Values in Ft Lbs \ (In Lb)
Table of Contents
Introduction ............................................................................................................................................ 1
Customer Support.................................................................................................................................... 1
Tools Required ......................................................................................................................................... 1
Components List ...................................................................................................................................... 2
Structural Components Views .................................................................................................................. 2
Step 1. Measure PV Mounting Hole Distance
.................................................................................................3
Step 2. Mounting Rail Supports on PV Module
.............................................................................................3
Step 3. Attaching Clips to Rails
.......................................................................................................................5
Step 4. Attaching Bucket to Pole
....................................................................................................................6
Step 5. Mounting PV Assembly on Pole ............................................................................................................7
Installer Responsibility
...................................................................................................................................8
Warranty Information .....................................................................................................................................8
Introduction
The UNI-SP/01A Side of Pole Mount is a simple and universal pole mounting solution for PV modules
with an area of less than 7 square feet. With its user-adjustable angle settings, the Side of Pole Mount
can support installations in a wide range of locations. These can be installed on 2 to 4 inch schedule 40
pipe which have an outside diameter of 2.375 inches to 4.5 inches, flat surfaces, and a 25G ROHN tower
frame. The module support rails can be adjusted for module tilt angles from 0 to 90 .
Customer Support
Tamarack Solar makes every effort to ensure your
mounting kit is easy to install. If you need assistance
at any point in your installation or have suggestions on how
we can improve your experience, call
customer
support at 1-800-819-7236 ext 556 or email us at support@tamaracksolar.com
Tools Required
Tools that support the following size Hex heads: The use of anti-seize lubricant on Stainless hardware is
highly recommended to reduce the chance of galling.
Torque wrench with a range of up to 144 inch-pounds or 12 Ft-Lbs
5/16 “ socket (for the hose clamps - torque to 35 Inch-pounds)
7/16 “ socket
1/2 “ socket

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
2
ITEM PART NUMBER DESCRIPTION QTY
1 51-3517-200 Bucket, 25.5" 1
2 51-3517-243 Clip, Left End 1
3 51-3517-244 Clip, Right End 1
4 51-0527-000 Rail, 27.5" 2
5 23-2520-050 Bolt, 1/4-20 x .75" Stainless steel 4
6 25-2502-000 Washer, flat 1/4" Stainless steel 8
7 25-2501-000 Washer, lock 1/4" Stainless steel 4
8 24-2520-440 Nut, 1/4-20 Hex Stainless steel 4
9 23-3118-021 Bolt, 5/16-18 x .75" Stainless steel 8
10 25-3102-000 Washer, flat 5/16" Stainless steel 16
11 25-3101-000 Washer, lock 5/16" Stainless steel 8
12 24-3118-440 Nut, 5/16-18 Hex Stainless steel 8
13 27-5000-010 Hose Clamp, 1/2" x 1.675" - 5" 2
14 29-5002-000 Kit, Spare (1/4" + 5/16") x 3/4" 1
Components List :
Structural Components Views
Bucket Hose clamps Left and right Clips
Panel Support Rails
Optional Components for mounting (Not included)
Depending on mounting surface:
1 : 1/2” - 13 x 2”, 3”, or 4” U-Bolt, with Flat and Lock Washers, and Nuts
-OR-
2 sets: 1/2” lag bolts and washers,
-OR-
2 each: 1 9/16” to 2 1/2” hose clamps
For 25G Rohn tower

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
3
Step 1: Measure PV Mounting Hole Distance
A. Lay the module(s) face down on a protected surface in the
suitable orientation.
B. Measure the center to center distance between the inside mounting holes on the back of the PV
module as shown and make a note of it.
Step 2: Mounting Rail Supports on PV Module
A.
Review the reference diagrams on next page to determine the orientation of the panel support
rails (facing in or out) and the end clips (facing in or out), based on the center to center hole
spacing of your solar module
B.
Secure the rails to the solar module with a 1/4-20 x 3/4 inch bolt, lock washer, and hex nut in each
of the solar module mounting holes. See the top of page 5 for reference view.
C.
Torque the bolts to the specified torque setting (see page 1).

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
4

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
5
Step 3: Attaching Clips to Rails
A. Attach the clips to the rails as determined by the bucket range diagrams (shown in previous step).
Example shown has the clips facing in on the inside of the rails that are facing out.
B. In each of the clip mounting holes, use a 5/16-18 x 3/4” bolt and flat washer on one side
and a flat washer, lock washer and nut on the other. Tighten these bolts finger tight
only at this time (these will be torqued after the assembly is finished and the tilt angle is
final.)
C. Note: For over-the-pole option, attach the clips on the middle set of holes on the panel supports, see
view on manual cover.

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
6
Step 4: Attaching Bucket to Pole
A.
Un-screw the hose clamp to release the end and
thread each hose clamp through one of the sets of
narrow center holes in the bucket(s) as shown and
place at the desired location on the pole. Keep the
solid section of the clamp thru the holes on the
bucket.
B.
Once the hose clamps are in the desired position,
tighten the hose clamp screws to 35 in-lbs
NOTE: ALWAYS RECHECK TORQUE ON HOSE
CLAMPS AFTER EXPOSURE TO WINDY
CONDITIONS.
Optional mounting hardware (not included)
C.
In high loading conditions, in conjunction with the
hose clamps, add the optional the optional 1/2-13 U-
Bolts as appropriate for the pipe size being used ( 2”
to 4” pipe size) Tighten securely but take care not to
deform the bucket
D.
Use 1/2” lag bolts as appropriate to a wooden
structure being mounted to (telephone pole or post
Etc.). Tighten securely but take care not to deform
the bucket
E.
Use (optional) hose clamps to attach
buckets to a 25G Rohn tower.
SOLID SECTION

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
7
Step 5. Mounting PV Assembly on Pole
A. Place the PV module assembly so the holes on the clips line up with holes in the inside of the bucket.
Depending on the size of the panel you started with, your assembly may look different than what is
shown in the provided view, with the clips and rails facing in the opposite direction.
B. Attach the clips to the bucket. In each of the 4 mounting holes, use a 5/16-18 x 3/4” bolt and flat
washer on one side and a washer, lock washer and nut on the other. Torque the bolts to the specified
torque setting.
C. Set desired module tilt angle and torque the bolts to the specified torque setting.

Installation
Manual
UNI
-
SP/01A
support@tamaracksolar.com 1
-
800
-
819
-
7236 Ext 556
Page
8
Installer Responsibility
The installer is solely responsible for:
i.
Complying with all applicable local or national building codes, including any that may supersede this manual.
ii.
Ensuring that Tamarack Solar and other products are appropriate for the particular installation and the
installation environment.
iii.
Using only Tamarack Solar parts and installer-supplied parts as specified by Tamarack Solar. Substitution
parts may void Warranty.
iv.
Ensuring safe installation of all electrical aspects of the PV array.
v.
Ensuring correct and appropriate design parameters are used in determining the design loading used for
the specific installation. Parameters, such as snow loading, wind speed, exposure and topographic factor
should be confirmed with the local building official or a licensed professional engineer.
NOTE: ALWAYS RECHECK TORQUE ON HOSE CLAMPS AFTER EXPOSURE TO WINDY CONDITIONS
Warranty Information
Tamarack Solar warrants each Mounting Structure to be free from defects in materials and workmanship for
ten (10)
years from the date of first purchase (“Warranty Period”), when installed properly and used for the
purpose for which it is designed, except for the finish, which shall be free from visible peeling, or cracking or
chalking under
normal atmospheric conditions for a period of three (3) years, from the earlier of 1) the date the
installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original
Purchaser (“Finish Warranty”).
The Finish Warranty does not apply to any foreign residue deposited on the
finish. All installations in corrosive atmospheric conditions are excluded. The Finish Warranty is VOID if the
practices specified by AAMA 609 & 610-02 – “Cleaning and Maintenance for Architecturally Finished
Aluminum” (www.aamanet.org) are not followed by Purchaser for Tamarack Solar’s aluminum based products.
The warranty covers the replacement cost of parts to repair the product to proper working condition.
Transportation and incidental costs associated with warranty items are not reimbursable. The warranty does
not
cover normal wear, or damage resulting from misuse, abuse, improper installation, negligence, or accident.
The warranty does not cover any defect that has not been reported in writing to Tamarack Solar within ten
(10) days after
discovery of such defect. Furthermore, it does not cover units that have been altered, modified
or repaired without
written authorization from the manufacturer or its authorized representative, or units
used in a manner or for a purpose other than that specified by the manufacturer. Tamarack Solar’s entire
liability and Purchaser exclusive remedy,
whether in contract, tort or otherwise, for any claim related to or
arising out of breach of the warranty covering the Mounting Structures shall be correction of defects by repair,
replacement, or credit, at Tamarack Solar’s discretion. Refurbished Mounting Structures may be used to repair
or replace the Mounting Structures.
Tamarack Solar shall have no liability for any injuries or damages to persons or property resulting from any cause,
whatsoever, or any claims or demands brought against Tamarack Solar by Purchaser, any employee of Purchaser,
client of Purchaser, end-user of the Product or other party, even if Tamarack Solar has been advised of the
possibility of such claims or demands (collectively, “Third Party Claims”). This limitation applies to all materials
provided by Tamarack Solar during and after the Warranty
Table of contents
Other Tamarack Solar Inverter manuals
Popular Inverter manuals by other brands

Victron energy
Victron energy Phoenix 12/225 user manual

SAJ
SAJ Suntrio-TL Series user manual

brennenstuhl
brennenstuhl SES P4033 V3 manual

Rockwell Automation
Rockwell Automation 2361-SPM04A user manual

Siemens
Siemens SG035 Series owner's manual

Mitsubishi Electric
Mitsubishi Electric PV-PNS04ATL-GER Operation manual