All copyrights, trademarks and any other intellectual property rights related are owned by Taoglas Group Holdings Limited.
Waiver: This document represents information compiled by Taoglas to the best of our current knowledge. This is not intended to be used as a
representation or warranty of fitness of the products described for any particular purpose. This document details guidelines for general information
purposes only. When planning installations, always seek specialist advice and ensure that the products are always installed by a properly qualified
installer in accordance with applicable regional laws and regulations.
Caution
To comply with FCC RF Exposure requirements in section 1.1310 of the FCC Rules, antennas used with this device must be installed
to provide a separation distance of at least 20 cm from all persons to satisfy RF exposure compliance.
Warning
Do not Operate the transmitter when someone is within 20 cm of the antenna.
Do not operate the equipment in an explosive atmosphere.
European Waste Electronic Equipment Directive 2002/96/EC
Please ensure that your old Waste Electricals and Electronics are recycled do not throw them away into standard waste.
IG-20-08-002 www.taoglas.com
D Notices
C Screw Mount Option
Unpack the iDAS antenna from the packaging and remove the connector caps from the 4.3-10 mini-DIN
connectors. The unique design of the iDAS.C.001 antenna also allows for screw mounting via two recessed
areas located on either side of the enclosure. Two rawlplugs and to M5 25mm screws are supplied however
you may wish to use an alternative depending on your desired installation location.
Prepare the ceiling by drilling three holes as per the dimensions in Fig. 4 below. Two ø6mm holes for the
rawlplugs and one ø20mm hole for the cable feed should be drilled in the desired location. When preparing
to drill the holes, mask the area around the hole position to protect the surrounding surface. Insert the
rawlplugs into the two 6mm holes.
Feed both cables through the 20mm hole and connect them to the cellular signal source cables. Position the
iDAS antenna in place taking care to align the mounting holes as per Fig 5 below. Screw the iDAS antenna
tightly into position on the mounting surface. Care should be taken to mount the iDAS antenna as far as
possible from other roof-mounted features such as air-con units, ceiling lights etc.
Fig. 5Fig. 4