Taylor C706 User manual

Model C706
Soft Serve Freezer
Original Operating Instructions
056436--M
February, 2003 (Original Publication)
(Updated May, 2011)

Complete this page for quick reference when service is required:
Taylor Distributor:
Address:
Phone:
Service:
Parts:
Date of Installation:
Information found on the data label:
Model Number:
Serial Number:
Electrical Specs: Voltage Cycle
Phase
Maximum Fuse Size: A
Minimum Wire Ampacity: A
EFebruary, 2003 Taylor
All rights reserved.
056436--M
The word Taylor and the Crown design
are registered trademarks in the United States
of America and certain other countries.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072

Table of Contents Model C706
Table of Contents
Section 1 To the Installer 1............................................
Section 2 To the Operator 4...........................................
Section 3 Safety 5....................................................
Section 4 Operator Parts Identification 7...............................
Model C706 7..........................................................
Model C706 Single Spout Door and Beater Assembly 8......................
X57029--XX Pump A. -- Mix Simplified 9...................................
Accessories 10..........................................................
Section 5 Important: To the Operator 11.................................
Symbol Definitions 12....................................................
Power Switch 12.........................................................
Indicator Lights 12.......................................................
MIX REF Key 12.........................................................
STANDBY Key 12........................................................
WASH Key 13...........................................................
AUTO Key 13...........................................................
Pump Key 13............................................................
Beater Motor Reset Button 13.............................................
Air/Mix Pump Reset Button 13.............................................
Adjustable Draw Handle 13...............................................
Feed Tube (Back--up Option) 14...........................................
Section 6 Operating Procedures 15.....................................
Prior to Set--Up (Freezers With Topping Pumps Only) 15......................
Assembly 15............................................................
Mix Hopper Assembly 18.................................................
Sanitizing 21............................................................
Priming 23..............................................................

Model C706 Table of Contents
Table of Contents -- Page 2
Closing Procedure 24....................................................
Draining Product From the Freezing Cylinder 25.............................
Rinsing 25..............................................................
Cleaning 25.............................................................
Disassembly 26..........................................................
Brush Cleaning 26.......................................................
Section 7 Important: Operator Checklist 28..............................
During Cleaning and Sanitizing 28.........................................
Troubleshooting Bacterial Count 28........................................
Regular Maintenance Checks 28...........................................
The Air/Mix Pump Checklist 29............................................
Winter Storage 29........................................................
Section 8 Troubleshooting Guide 30....................................
Section 9 Parts Replacement Schedule 34...............................
Section 10 Parts List 35.................................................
Wiring Diagram 43.......................................................
Note: Continuing research results in steady improvements; therefore, information
in this manual is subject to change without notice.
Note: Only instructions originating from the factory or its authorized translation
representative(s) are considered to be the original set of instructions.
EFebruary, 2003 Taylor (Original Publication)
(Updated May, 2011)
All rights reserved.
056436--M
The word Taylor and the Crown design
are registered trademarks in the United States
of America and certain other countries.
Taylor Company
750 N. Blackhawk Blvd.
Rockton, IL 61072

1
Model C706 To the Installer
081208
Section 1 To the Installer
The following are general installation instructions. For
complete installation details, please see the check out
card.
Installer Safety
In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
SOnly authorized Taylor service personnel
should perform installation and repairs on
the equipment.
SAuthorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
SAuthorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and
service.
SAuthorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the freezer must
be disconnected prior to performing any repairs.
Failure to follow this instruction may result in personal
injury or death from electrical shock or hazardous
moving parts as well as poor performance or damage
to the equipment.
Note:Allrepairsmustbeperformedbyan
authorized Taylor Service Technician.
This unit has many sharp edges that can
cause severe injuries.
Site Preparation
Review the area the unit is to be installed in before
uncrating the unit making sure that all possible
hazards the user or equipment may come into have
been addressed.
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
The model C706 air cooled unit requires a minimum of
6” (152 mm) of clearance on both sides and 0” in the
rear of the unit. This will allow for adequate air flow
across the condenser(s). Failure to allow adequate
clearance can reduce the refrigeration capacity of the
freezer and possibly cause permanent damage to the
compressor.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70_-75_F(21_-24_C). The freezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
This unit must NOT be installed in an area
where a water jet or hose can be used. NEVER use a
water jet or hose to rinse or clean the unit. Failure to
follow this instruction may result in electrocution.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should be
taken in moving this equipment for any reason. Two or
more persons are required to safely move this unit.
Failure to comply may result in personal injury or
equipment damage.
Uncrate the unit and inspect it for damage. Report any
damage to your Taylor Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.

2Model C706To the Installer
101027
Water Connections
(Water Cooled Units Only)
An adequate cold water supply must be provided with
a hand shut--off valve. On the underside rear of the
base pan, two 3/8” I.P.S. water connections for inlet
and outlet have been provided for easy hook--up. 1/2”
inside diameter water lines should be connected to the
machine. (Flexible lines are recommended, if local
codes permit.) Depending on local water conditions, it
may be advisable to install a water strainer to prevent
foreign substances from clogging the automatic water
valve. There will be only one water “in” and one water
“out” connection. DO NOT install a hand shut--off valve
on the water “out” line! Water should always flow in this
order: first, through the automatic water valve; second,
through the condenser; and third, through the outlet
fitting to an opentrapdrain.
A back flow prevention device is required
on the incoming water connection side. Please
refer to the applicable National, State, and local codes
for determining the proper configuration.
Electrical Connections
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70-1987. The purpose of the
NEC code is the practical safeguarding of persons and
property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. In all other areas of the world,
equipment should be installed in accordance with the
existing local codes. Please contact your local
authorities.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the freezer
for branch circuit overcurrent protection or fuse, circuit
ampacity, and other electrical specifications. Refer to
the wiring diagram provided inside of the electrical box
for proper power connections.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
DO NOT operate this freezer with larger fuses
than specified on the unit data label. Failure to follow
this instruction may result in electrocution or damage
to the machine.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipments frame.
Stationary appliances which are not equipped
with a power cord and a plug or another device to
disconnect the appliance from the power source must
have an all-pole disconnecting device with a contact
gap of at least 3mm installed in the external
installation.
Appliances that are permanently connected to
fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected or not
used for long periods, or during initial installation, shall
have protective devices such as a GFI, to protect
against the leakage of current, installed by the
authorized personnel to the local codes.

3
Model C706 To the Installer
080828
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable not lighter than
ordinary polychloroprene or other equivalent synthetic
elastomer-sheathed cord (Code designation 60245
IEC 57) installed with the proper cord anchorage to
relieve conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedures should be
performed by a trained service technician.
To correct the rotation on a three--phase unit,
interchange any two incoming power supply lines at
freezer main terminal block only.
To correct rotation on a single--phase unit, change the
leads inside the beater motor. (Follow the diagram
printedonthemotor.)
Electrical connections are made directly to the
terminal block provided in the main control box.
Refrigerant
In consideration of our environment, Taylor
proudly uses only earth friendly HFC refrigerants. The
HFC refrigerant used in this unit is R404A. This
refrigerant is generally considered non-toxic and
non-flammable, with an Ozone Depleting Potential
(ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.

4Model C706To the Operator
080714
Section 2 To the Operator
The Model C706 has been carefully engineered and
manufactured to give you dependable operation.
This unit, when properly operated and cared for, will
produce a consistent quality product. Like all
mechanical products, it will require cleaning and
maintenance. A minimum amount of care and
attention is necessary if the operating procedures
outlined in this manual are followed closely.
This Operator’s Manual should be read before
operating or performing any maintenance on your
equipment.
Your Taylor freezer will NOT eventually compensate
for and correct any errors during the set--up or filling
operations. Thus, the initial assembly and priming
procedures are of extreme importance. It is strongly
recommended that personnel responsible for the
equipment’s operation, both assembly and
disassembly, go through these procedures together in
order to be properly trained and to make sure that no
confusion exists.
In the event you should require technical assistance,
please contact your local authorized Taylor Distributor.
Note: Warranty is valid only if the parts are authorized
Taylor parts, purchased from an authorized Taylor
Distributor, and the required service work is provided
by an authorized Taylor service technician. Taylor
reserves the right to deny warranty claims on
equipment or parts if non--approved parts or
refrigerant were installed in the machine, system
modifications were performed beyond factory
recommendations, or it is determined that the failure
was caused by neglect or abuse.
If the crossed out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive as well as other similar
legislation in effect after August 13, 2005. Therefore,
it must be collected separately after its use is
completed, and cannot be disposed as unsorted
municipal waste.
The user is responsible for returning the product to the
appropriate collection facility, as specified by your local
code.
For additional information regarding applicable local
laws, please contact the municipal facility and/or local
distributor.
Compressor Warranty Disclaimer
The refrigeration compressors on this machine are
warranted for the term indicated on the warranty card
accompanying this machine. However, due to the
Montreal Protocol and the U.S. Clean Air Act
Amendments of 1990, many new refrigerants are
being tested and developed, thus seeking their way
into the service industry. Some of these new
refrigerants are being advertised as drop--in
replacements for numerous applications. It should be
noted that, in the event of ordinary service to this
machine’s refrigeration system, only the refrigerant
specified on the affixed data label should be used.
The unauthorized use of alternate refrigerants will void
your compressor warranty. It will be the owner’s
responsibility to make this fact known to any technician
he employs.
It should also be noted that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service
to this machine, Taylor has no obligation to either
supply or provide its replacement either at billable or
unbillable terms. Taylor does have the obligation to
recommend a suitable replacement if the original
refrigerant is banned, obsoleted, or no longer available
during the five year warranty of the compressor.
Taylor will continue to monitor the industry and test
new alternates as they are being developed. Should a
new alternate prove, through our testing, that it would
be accepted as a drop--in replacement, then the above
disclaimer would become null and void. To find out the
current status of an alternate refrigerant as it relates to
your compressor warranty, call the local Taylor
Distributor or the Taylor Factory. Be prepared to
provide the Model/Serial Number of the unit in
question.

5
Model C706 Safety
110301
Section 3 Safety
We at Taylor Company are concerned about the safety
of the operator when he or she comes in contact with
the freezer and its parts. Taylor has gone to extreme
efforts to design and manufacture built--in safety
features to protect both you and the service technician.
As an example, warning labels have been attached to
the freezer to further point out safety precautions to the
operator.
IMPORTANT -- Failure to adhere to the
following safety precautions may result in severe
personal injury or death. Failure to comply with
these warnings may damage the machine and its
components. Component damage will result in
part replacement expense and service repair
expense.
DO NOT operate the freezer without reading
this Operator Manual. Failure to follow this instruction
may result in equipment damage, poor freezer
performance, health hazards, or personal injury.
Per IEC 60335--1 and its part 2 standards, “This
appliance is to be used only by trained personnel. It is
not intended for use by children or people with reduced
physical, sensory, or mental capabilities, or lack of
experience and knowledge, unless given supervision
or instruction concerning the use of the appliance by
a person responsible for their safety.”
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipments frame.
DO NOT use a water jet to clean or rinse the
freezer. Failure to follow these instructions may result
in serious electrical shock.
SDO NOT operate the freezer unless it is
properly grounded.
SDO NOT operate the freezer with larger
fuses than specified on the freezer data
label.
SAll repairs must be performed by an
authorized Taylor service technician. The
main power supplies to the machine must
be disconnected prior to performing any
repairs.
SCord Connected Units: Only Taylor
authorized service technicians may install a
plug on this unit.
SStationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an all-pole
disconnecting device with a contact gap of
at least 3mm installed in the external
installation.
SAppliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected or not used for long
periods, or during initial installation, shall
have protective devices such as a GFI, to
protect against the leakage of current,
installed by the authorized personnel to the
local codes.
SSupply cords used with this unit shall be
oil-resistant, sheathed flexible cable not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.

6Model C706Safety
080908
SDO NOT allow untrained personnel to
operate this machine.
SDO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
SDO NOT remove any internal operating
parts (examples: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in severe
personal injury to fingers or hands from hazardous
moving parts.
This unit has many sharp edges that can
cause severe injuries.
SDO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
SUSE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
SCAUTION--SHARP EDGES: Two people
are required to handle the cup/cone
dispenser. Protective gloves must be worn
and the mounting holes must NOT be used
to lift or hold the dispenser. Failure to follow
this instruction can result in personal injury
to fingers or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
DO NOT obstruct air intake and discharge openings:
A minimum of 6” (152 mm) air space is required on
both sides and 0” on the rear. Failure to follow this
instruction may cause poor freezer performance and
damage to the machine.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of 70_-
75_F(21_-24_C). The freezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.

7
Model C706 Operator Parts Identification
110509
Section 4 Operator Parts Identification
ITEM DESCRIPTION PART NO.
1COVER-HOPPER-BLACK 053809-1
2PAN-DRIP 11-5/8 LONG 027503
3PIN-RETAINING-HOPPER CVR 043934
4PANEL-SIDE-LEFT 066722-SP2
5STUD-NOSE CONE 055987
6SHIELD-SPLASH 049203
7TRAY-DRIP 056858
8PANEL-FRONT-LOWER 058942
9PANEL A.-FRONT-UPPER X58950
ITEM DESCRIPTION PART NO.
10 PANEL A.-SIDE RIGHT
(STD. UNIT ONLY, NOT TOP
AIR DISCHARGE)
X64151
11 PANEL-REAR 056077
12 PAN A.-DRIP 5-1/2” LONG X56074
13 PUMP A.-MIX SIMPLIFIED S.S. X57029-14
14 PANEL A.-SIDE RIGHT (TOP
AIR DISCHARGE UNITS, ONLY) X65441-SER
15 GUARD-FAN 028534-1

8Model C706Operator Parts Identification
110509
Model C706 Single Spout Door and Beater Assembly
ITEM DESCRIPTION PART NO.
1DOOR A.--W/BAFFLE X56071--SER
2HANDLE A.-DRAW-WELDED X56246
3SCREW-ADJUSTMENT-5/16-24 056332
4O-RING-1/4 OD X .070W 50 015872
5PIN--HANDLE--S.S. 055819
6PLUG -- PRIME 028805
7O--RING -- 3/8 OD X .070W 016137
8VALVE A. -- DRAW X56072
9O--RING -- 7/8 OD X .103 W 014402
ITEM DESCRIPTION PART NO.
10 NUT--STUD BLACK--3.25 LONG 058765
11 NUT--STUD BLACK--2.56 LONG 058764
12 GASKET--DOOR HT 4” DBL 048926
13 KIT A.--BEATER FRONT SHOE X50350
14 BEATER A. -- 3.4 QT. -- 1 PIN X46231
15 CLIP -- SCRAPER BLADE -- 7” 046236
16 BLADE--SCRAPER--PLASTIC 046235
17 SHAFT -- BEATER 056078
18 SEAL -- DRIVE SHAFT 032560

9
Model C706 Operator Parts Identification
050617
X57029--XX Pump A. -- Mix Simplified
Figure 1
ITEM DESCRIPTION PART NO.
1-7 PUMP ASSEMBLY - MIX
SIMPLIFIED SOFT SERVE X57029-XX
1CYLINDER A.-PUMP-HOPPER-
SOFT SERVE X57025
2PIN A.-COAX PUMP X55450
3PISTON 053526
4O-RING 2-1/8” OD - RED 020051
5CAP-VALVE 056874-12
6GASKET - SIMPLIFIED PUMP
VALVE 053527
7ADAPTOR - MIX INLET 054825
8O-RING - 11/16 OD - RED 016132
ITEM DESCRIPTION PART NO.
9PIN - COTTER 044731
10 SHAFT A.-DRIVE-MIX PUMP-
HOPPER X39084
10a CRANK-DRIVE 039235
10b SHAFT-DRIVE 039106
10c O-RING - DRIVE SHAFT 048632
10d O-RING 1-3/4 008904
11 TUBE A.-FEED HOPPER
SOFT SERVE X56521
12 RING-CHECK .120 OD 056524
13 CLIP-MIX PUMP RETAINER 044641

10 Model C706Operator Parts Identification
110509
Accessories
Figure 2
ITEM DESCRIPTION PART NO.
1TOOL-O-RING REMOVAL 048260-WHT
2BRUSH-REAR·BRG·1IN.DX2IN. 013071
3BRUSH-DOUBLE·ENDED 013072
4BRUSH-DRAW·VALVE·1”ODX2 013073
5BRUSH-MIX·PUMP·BODY-3”X7 023316
6
SANITIZER STERA SHEEN
(JAR) 010425-CS
SANITIZER STERA SHEEN
(100/2 OZ. PACKETS) 055492
ITEM DESCRIPTION PART NO.
7PAIL-MIX 10 QT. 013163
8BRUSH-END-DOOR-SPOUT 039719
9BRUSH-SET·LVB 050103
10 BRUSH-PUMP·SPOUT 054068
*Item 6: A sample of Stera Sheen is shipped with new
equipment. To order additional sanitizer, use one of the
part numbers listed.

11
Model C706 Important: To the Operator
041118
Section 5 Important: To the Operator
C706
Figure 3
ITEM DESCRIPTION
1MIX LOW INDICATOR LIGHT
2MIX OUT INDICATOR LIGHT
3MIX REFRIGERATION KEY
4STANDBY KEY
5WASH KEY
6AUTO KEY
ITEM DESCRIPTION
7PUMP KEY
8RESET BUTTON -- BEATER MOTOR
9RESET BUTTON -- PUMP
10 POWER SWITCH (TOGGLE)
11 HOPPER TEMP. INDICATOR
*12 OPTIONAL FLAVOR BURST JACK
*MAY NOT BE AVAILABLE ON ALL UNITS.

12 Model C706Important: To the Operator
Symbol Definitions
To better communicate in the International arena,
symbols have replaced words on many of our operator
switches, function, and fault indicators. Your Taylor
equipment is designed with these International
symbols.
The following chart identifies the symbol definitions.
=OFF
=ON
=MIXLOW
= MIX OUT
=MIXREF
= STANDBY
= WASH
=AUTO
=PUMP
Power Switch
When placed in the ON position, the power switch
allows SOFTECH control panel operation.
Indicator Lights
When the MIX LOW light begins to flash, it indicates
that the mix tank has a low supply of mix and should
be refilled as soon as possible. When the MIX OUT
light begins to flash, it indicates that the mix tank has
been almost completely exhausted and has an
insufficient supply of mix to operate the freezer. At this
time, the STANDBY and AUTO modes are locked out
and the freezer shuts down. To initiate the refrigeration
system, add mix to the tank and press the AUTO key.
The freezer will automatically begin operation.
MIX REF Key
When the MIX REF key is pressed, the light comes on
indicating the mix hopper refrigeration system is
operating. The MIX REF function cannot be cancelled
unless the AUTO or STANDBY modes are cancelled
first.
STANDBY Key
The Separate Hopper Refrigeration System (SHR)
and the Cylinder Temperature Retention System
(CTR) are standard features. The SHR incorporates
the use of a separate small refrigeration system to
maintain the mix in the hopper below 40_(4.4_C) to
assure bacteria control. The CTR works with the SHR
to maintain a good quality product. During long “No
Sale” periods, it is necessary to warm the product in
the freezing cylinder to approximately 35_Fto40_F
(1.7_Cto4.4_C) to prevent overbeating and product
breakdown.
To activate the SHR and CTR, press the STANDBY
key. Remove the air orifice and place the feed tube
(end without the hole) into the mix inlet hole.
When the STANDBY key is pressed, the light comes
on, indicating the CTR (Cylinder Temperature
Retention System) has been activated. In the
STANDBY mode, the WASH and AUTO functions are
automatically cancelled. The MIX REF function is
automatically locked in to maintain the mix in the
hopper.
To resume normal operation, press the AUTO key.
When the unit cycles off, the product in the freezing
cylinder will be at serving viscosity. At this time, place
the feed tube (end with the hole) into the mix inlet
hole and install the air orifice.

13
Model C706 Important: To the Operator
060518
WASH Key
When the WASH key is pressed, the light comes on.
This indicates beater motor operation. The STANDBY
or AUTO modes must be cancelled first to activate the
WASH mode.
AUTO Key
When the AUTO key is pressed, the light comes on.
This indicates that the main refrigeration system has
been activated. In the AUTO mode, the WASH or
STANDBY functions are automatically cancelled. The
MIX REF function is automatically locked in to
maintain the mix in the mix hopper.
Note: An indicating light and an audible tone will
sound whenever a mode of operation has been
pressed. To cancel any function, press the key again.
The light and mode of operation will shut off.
Pump Key
When the PUMP key is pressed, the light comes on,
indicating the air/mix pump will operate as required.
Beater Motor Reset Button
The reset button is located on the left side of the unit.
The reset protects the beater motor from an overload
condition. If an overload occurs, the reset mechanism
will trip. To properly reset the freezer, press the AUTO
key to cancel the cycle. Turn the power switch to the
OFF position. Press the reset button firmly.
Do not use metal objects to press the reset
button. Failure to follow this instruction may
result in electrocution.
Turn the power switch to the ON position. Press the
WASH key and observe the freezer’s performance.
Open the side access panel. Make sure the beater
motor is turning the drive shaft in a clockwise direction
(from the operator end) without binding.
If the beater motor is turning properly, press the WASH
key to cancel the cycle. Press the AUTO key to resume
normal operation. If the freezer shuts down again,
contact a service technician.
Air/Mix Pump Reset Button
The reset button for the pump is located on the left side
of the unit. This reset protects the pump from an
overload condition. Should an overload occur, the
reset mechanism will trip. To reset the pump, press the
reset button firmly.
Adjustable Draw Handle
The Model C706 features an adjustable draw handle
to provide the best portion control. The draw handle
should be adjusted to provide a flow rate of 5 to 7--1/2
oz. of product per 10 seconds. To INCREASE the flow
rate, turn the screw CLOCKWISE. Turn the screw
COUNTER--CLOCKWISE to DECREASE the flow
rate.
Figure 4

14 Model C706Important: To the Operator
050126
Feed Tube (Back--up Option)
If the air/mix pump has become inoperable because of
a missing or damaged part, the operator can
temporarily operate the unit using the feed tube. The
product ejection rate will be slower when the feed tube
is used instead of the air/mix pump.
Figure 5
ITEM DESCRIPTION PART NO.
1ORIFICE 022465--100
2O--RING--3/8 OD X .070 W 016137
3TUBE A.--FEED--SS 5/32 HOLE X29429--2
4O--RING--.643 OD X .077 W 018572
The feed tube serves two purposes. One end of the
tube has a hole and the other end does not.
1. Normal Operation
During normal operation, the end of the feed tube
with the hole is placed into the mix inlet hole.
Every time the draw handle is raised, new mix and
air from the hopper flow into the freezing cylinder.
This keeps the freezing cylinder properly loaded
and maintains overrun.
2. Long “No Sale” Periods
During long “No Sale” periods, the unit can be
placed into the Standby mode. This maintains
product temperatures below 40_F(4.4_C) in both
the hopper and the freezing cylinder, and helps
prevent overbeating and product breakdown.
To place the unit into the Standby mode, press the
STANDBY key. Remove the air orifice. Lubricate
the o--rings located on the end of the feed tube
without the hole. Place that end of the tube into
the mix inlet hole.This will prevent any mix from
entering the freezing cylinder.
Note: The air orifice is used to meter a certain
amount of air into the freezing cylinder. The air
orifice maintains overrun and allows enough mix
to enter the freezing cylinder after a draw.

15
Model C706 Operating Procedures
080714
Section 6 Operating Procedures
The C706 unit stores mix in a hopper. The mix is
pumped into the freezing cylinder. It has a 3.4 quart
(3.2 liter) capacity freezing cylinder and a 20 quart
(18.9 liter) mix hopper.
We begin our instructions at the point where we enter
the store in the morning and find the parts
disassembled and laid out to air dry from the previous
night’s cleaning.
These opening procedures will show you how to
assemble these parts into the freezer, sanitize them,
and prime the freezer with fresh mix in preparation to
serve your first portion.
If you are disassembling the machine for the first time
or need information to get to this starting point in our
instructions, turn to page 26, “Disassembly”, and start
there.
Prior to Set--Up (Freezers With
Topping Pumps Only)
Remove the stainless steel syrup jar with the topping
pump from the syrup rail. Check the water level in the
well. Make sure the water is filled to the indicating mark
on the inside wall (16 oz / 473 ml). Check the water
daily.
Place the heater switch in the ON position. The heating
process will take approximately 1--1/4 hours.
Prepare a pail of an approved 100 PPM sanitizing solu-
tion (examples: Kay--5Ror Stera--SheenR). USE
WARM WATER AND FOLLOW THE MANUFAC-
TURER’S SPECIFICATIONS.
Sanitize the pump by placing the entire asssembly in
the solution. Pump the solution through the pump until
it is sanitized.
Fill the heated and the room temperature syrup jars
with toppings. Place the topping pump in the heated
syrup jar. Sanitize the ladle and place it in the room
temperature jar.
Assembly
Note: When lubricating parts, use an approved food
grade lubricant (example: Taylor Lube).
MAKE SURE POWER SWITCH IS IN THE
“OFF” POSITION! Failure to follow this instruction
may result in severe personal injury from hazardous
moving parts.
Step 1
Install the drive shaft. Lubricate the groove and shaft
portion that comes in contact with the bearing on the
beater drive shaft. Slide the seal over the shaft and
groove until it snaps into place. DO NOT lubricate the
hex end of the drive shaft.
Fill the inside portion of the seal with 1/4” more
lubricant and lubricate the flat side of the seal that fits
onto the rear shell bearing.
Figure 6

16 Model C706Operating Procedures
041118
Insert the drive shaft into the freezing cylinder, hex end
first, and into the rear shell bearing until the seal fits
securely over the rear shell bearing. Engage the hex
end firmly into the drive coupling. Be sure the drive
shaft fits into the drive coupling without binding.
Figure 7
Step 2
Install the beater assembly. First check the scraper
blades for any nicks or signs of wear. If any nicks are
present, or if the blades are worn, replace both blades.
If the blades are in good condition, install the scraper
blade clips on the scraper blades. Place the rear
scraper blade over the rear holding pin on the beater.
Note: The hole on the scraper blade must fit securely
over the pin to prevent costly damage.
Figure 8
Holding the rear blade on the beater, slide it halfway in-
to the freezing cylinder. Install the front scraper blade
over the front holding pin.
Install the beater shoes.
Figure 9
Slide the beater assembly the rest of the way into the
freezing cylinder.
Make sure the beater assembly is in position over the
drive shaft. Turn the beater slightly to be certain that
the beater is properly seated. When in position, the
beater will not protrude beyond the front of the freezing
cylinder.
Step 3
Assemble the freezer door. Place the large rubber
gasket into the groove on the back side of the freezer
door.
Slide the white plastic front bearing over the baffle rod
onto the bearing hub making certain that the flanged
end of the bearing is resting against the freezer door.
Do not lubricate the gasket or the front bearing.
Figure 10
Other manuals for C706
1
Table of contents
Other Taylor Freezer manuals

Taylor
Taylor Taylormate 152 User manual

Taylor
Taylor C709 User manual

Taylor
Taylor C723 User manual

Taylor
Taylor Model C043 User manual

Taylor
Taylor H60 User manual

Taylor
Taylor 0736 User manual

Taylor
Taylor Model C043 User manual

Taylor
Taylor 369 User manual

Taylor
Taylor 358 User manual

Taylor
Taylor 342 Tim Hortons User manual