Taylor C832 User manual

SERVICE
MANUAL
McDonald's IntelliGap Grills
C832/C834/C835/C836/C838/C842/C844/C845
072768-S 4/19/11 (Original Publication)
(Updated 1/25/16)


Table of Contents McDonald's Intelligap Grills
Table of Contents
Section 1: Introduction 1...............................................
Safety 2.............................................................
Installation Instructions 4...............................................
Environmental Notices 5...............................................
Model C832 Specifications 6...........................................
Model C834 Specifications 7...........................................
Model C835 Specifications 8...........................................
Model C836 Specifications 9...........................................
Model C838 Specifications 10...........................................
Model C842 Specifications 11...........................................
Model C844 Specifications 12...........................................
Model C845 Specifications 13...........................................
Patty Placement Guides 14.............................................
Section 2: Controls and Systems 17......................................
Control Keys 18........................................................
Control Overview 21....................................................
Control Operation 22...................................................
LonWorks® Gateway 47................................................
Software Loading Procedures 50.........................................
Electrical Power Distribution 52..........................................
Amp Draw 53..........................................................
Pneumatic System 59..................................................
Model C835 & C845 Gas Connections 60.................................
Model C835 & C845 Heating System Operation - Domestic 63...............
Model C845 Heating System Operation - Pimple Pilot 64....................
Model C835 & C845 Ignition Detection Control - Domestic 65................
High Voltage Gas System - IDC Overview 66..............................
C832/C834/C835 (Two Platen Models) Exhaust Hoods 71..................
C842/C844/C845 (Three Platen Models) Exhaust Hoods 72.................

McDonald's Intelligap Grills Table of Contents
Table of Contents - Page 2
Section 3: Troubleshooting 73...........................................
General Troubleshooting Guide 74.......................................
Error Messages 81.....................................................
Motor/Platen Troubleshooting 82.........................................
“Probe Open” Troubleshooting Chart 91..................................
“Probe Fail“ Troubleshooting Chart 92....................................
“Clam Still Latched” Troubleshooting Chart 93.............................
“Clam Did Not Latch” Troubleshooting Chart 94............................
Meat Quality Troubleshooting 95.........................................
Section 4: Parts 97......................................................
Warranty Explanation 98................................................
C832 Exploded View 100................................................
C834 Exploded View 102................................................
C835 Exploded View 104................................................
C836 Exploded View 106................................................
C838 Exploded View 108................................................
C842 Exploded View 110................................................
C844 Exploded View 112................................................
C845 Exploded View 114................................................
Control A.-Box - X72514-12 (C832 - 60 Hz) 116.............................
Control A.-Box - X72514-40 (C832 - 50 Hz) 118.............................
Control A.-Box - X73133-12 (C835 - 60 Hz) 120.............................
Control A.-Box - X73133-40 (C835 - 50 Hz) 122.............................
Control A.-Box - X83099-27 (C836 & C838) 124............................
Control A.-LON - X83096-26 (C836 & C838, SN M5057035 & Prior) 125.......
Control A.-Lower - X72707-23 (60 Hz) -75 (50 Hz) (C842/C844) 126..........

Table of Contents McDonald's Intelligap Grills
Table of Contents - Page 3
Control A.-Lower - X73383-23 (60 Hz) -75 (50 Hz) (C845) 127................
Control A.-Upper - X72827-12 (C842 - 60 Hz) 128...........................
Control A.-Upper - X72889-40 (C842/C844 - 50 Hz) 129.....................
Control A.-Upper - X73384-12 (C845 - 60 Hz) 130...........................
Control A.-Upper - X73696-40 (C845 - 50 Hz) 132...........................
Control A.- Switch - X79377-SER / X79377-INT (C832/C834/C835) 134........
Control A.-Switch - X83527-INT (C836 & C838) 135.........................
Control A.-Switch - X72433 / X72433-INT (C842/C844) 136..................
Control A.- Switch - X73393 (C845) 137....................................
Transformer A. - X73649 (60 Hz) -26 (50 Hz) (C845) 138....................
Platen A.-Ser - X73333-23 (60 Hz) -75 (50 Hz) (C832/C834/C835/C836/C838) . . .
139
Platen A.-Serv - X73182-23 / -21 (C842/C844/C845 ) 141....................
Platen A.-2450W 230V Serv - X73183-75 (C842/C844/C845) 143.............
Platen A.-Serv WA - X73598-23 / -21 (C842) 145...........................
Platen A.-Serv WA - X73599-75 (C842) 147................................
Springs (C832/C834/C835/C836/C838) 149................................
Springs (C842/C844/C845) 150...........................................
Motor A.-Mount - X73115 (C832/C834/C835/C836/C838) 151................
Motor A.-Mount - X72403 (C842/C844/C845) 152...........................
Manifold Assembly - 073129 (C832/C834/C835) 153........................
Manifold Assembly - 083762 (C836 & C838) 154............................
Manifold Assembly - 072695 (C842/C844/C845) 155........................
Manifold Assembly - X79373-02 (C835) 156................................
Manifold Assembly - X78891-40 (C835 High Voltage) 157....................
Manifold Assembly - X73109-02 (C845) 158................................
Manifold Assembly - X73695-03 (C845 High Voltage) 159....................

McDonald's Intelligap Grills Table of Contents
Table of Contents - Page 4
Compressor A.-Air - X73128-12 (60 Hz) -27 (50 Hz) (C832) 160..............
Compressor A.-Air - X73288-27 (C834) 161................................
Compressor A.-Air - X73143- (C835) 162..................................
Compressor A.-Air - X83304-34 (C836 & C838) 163.........................
Compressor A.-Air - X72724-12 (60 Hz) -27 (50 Hz) (C842/C844) 164.........
Compressor A.-Air - X73108-12 (60 Hz) -27 (50 Hz) (C845) 165..............
Accessories (C832/C834/C835/C836/C838) 166............................
Accessories (C842/C844/C845) 167.......................................
Parts List 168...........................................................
Wiring Diagrams 200....................................................
CAUTION: Information in this manual is intended to be used by Taylor Authorized
Service Technicians only.
Note: Only instructions originating from the factory or its authorized translation
representative(s) are considered to be the original set of instructions.
Note: Continuing research results in steady improvements; therefore, information
in this manual is subject to change without notice.
E2011 Carrier Commercial Refrigeration, Inc. (Original Publication)
(Updated January, 2016)
072768-S
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this
work may be a violation of Copyright Law of the United States of America and other countries, could result
in the awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result
in further civil and criminal penalties.
All rights reserved.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072

1
McDonald's Intelligap Grills Introduction
Section 1: Introduction
SSafety
SInstallation Instructions
SSpecifications
SEnvironmental Notices
SPatty Placement Guides

2
Introduction McDonald's Intelligap Grills
Safety
We, at Taylor Company, are deeply committed to
manufacturing safe operating and serviceable
equipment. The many built-in safety features that
are part of all Taylor equipment are aimed at
protecting operators and trained service technicians
alike.
This manual is intended exclusively for
Taylor Company authorized service personnel.
DO NOT operate the grill before reading
the Operator's Manual. Failure to follow this
instruction may result in equipment damage, poor
grill performance, health hazards, or personal injury.
In all areas of the world, equipment should
be installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
SOnly authorized Taylor service personnel
should perform installation and repairs on
the equipment.
SAuthorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
SAuthorized service personnel must ensure
that the proper PPE (Personal Protective
Equipment) is available and worn when
required during installation and service.
SAuthorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
Take precautions to protect eyes, lungs, and
all parts of the body from potential harm when using
any chemical cleaner. Failure to follow this
instruction may result in a chemical burn. Please
refer to the product MSDS for additional safety
information.
Use extreme caution when installing,
servicing, operating, and cleaning the grill.
SAVOID CONTACT with hot grill surfaces or
hot grease.
SDO NOT prepare or remove product without
proper equipment.
SDO NOT allow untrained personnel to
operate the grill.
SUse extreme caution when cleaning the grill.
Failure to follow these instructions could result in
severe burns from high temperatures.
This equipment must be properly
grounded!
Do not operate this unit unless it is properly
grounded and all service panels and access doors
are restrained with screws. Failure to do so can
result in severe personal injury from electrical shock!
SDO NOT operate the grill with larger fuses
than specified on the data label.
SDO NOT attempt any repairs unless the
power supply to the grill has been
disconnected.
Failure to follow these instructions may result in
severe personal injury from electrical shock.

3
McDonald's Intelligap Grills Introduction
This unit has many sharp edges that can
cause severe injuries.
This unit must NOT be installed in an area
where a water jet or hose can be used.
NEVER use a water jet or hose to rinse or clean the
unit.
Failure to follow these instructions may result in
electrocution, burns from hot steam, or liquid
collecting inside the grill and destroying electrical
components.
This grill must be placed on a level surface.
Failure to comply may result in personal injury or
equipment damage.
SDO NOT store flammable vapors, liquids, or
combustible material in the vicinity of the
grill.
SAppropriate grill clearance must be
maintained.
Failure to comply could result in a fire hazard.
NOISE LEVEL: Airborne noise emission does not
exceed 70 dB(A) when measured at a distance of
1.0 meter from the surface of the machine and at a
height of 1.6 meters from the floor.

4
Introduction McDonald's Intelligap Grills
Installation Instructions
The following are general installation instructions.
For complete installation details, please see the
checkout card.
Site Preparation
Review the area where the unit is to be installed
before uncrating the unit. Make sure all possible
hazards to the user and the equipment have been
addressed.
For Indoor Use Only: This unit is designed to
operate indoors, under normal ambient
temperatures of 70° 75°F (21° 24°C). The unit
has successfully performed in high ambient
temperatures of 104°(40°C) at reduced capacities.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should
be taken in moving this equipment for any reason.
Two or more people are required to safely move this
unit. Failure to comply may result in personal injury
or equipment damage.
When uncrating the unit, inspect the unit for
damage. Report any damage to your Taylor
Distributor.
This piece of equipment is made in the USA and has
USA sizes of hardware. All metric conversions are
approximate and vary in size.
Electrical Connections
Three dedicated electrical connections are required
for the models C832, C834, C842, and C844 (two 3
phase and one interlock/control single phase). Two
dedicated electrical connections are required for the
models C835, C836, C838, and C845 (one 3 phase
and one interlock/control single phase). Check the
data plate on the grill for voltage, cycle, phase and
electrical specifications. The power connections are
located behind the access line cover on the rear of
the control box under the front staging side of the
grill.
In the United States, this equipment is intended to
be installed in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70-1987. The
purpose of the NEC code is the practical
safeguarding of persons and property from hazards
arising from the use of electricity. This code contains
provisions considered necessary for safety.
Compliance therewith and proper maintenance will
result in an installation essentially free from hazard!
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
The proper wire size and fused circuit should be
selected according to grill data label information.
Incoming power must be connected to the terminals
with black characters on a white background.
This equipment must be properly
grounded!
Do not operate this unit unless it is properly
grounded and all service panels and access doors
are restrained with screws. Failure to do so can
result in severe personal injury from electrical shock!
This equipment is provided with a grounding lug
that is to be properly attached to the rear of the frame
by the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021 of
IEC 60417-1) on the removable panel and the frame.

5
McDonald's Intelligap Grills Introduction
Appliances that are permanently connected
to fixed wiring and for which leakage currents may
exceed 10 mA, particularly when disconnected, not
used for long periods, or during initial installation,
shall have protective devices such as a GFI, to
protect against the leakage of current, installed by
the authorized personnel to the local codes.
Stationary appliances which are not
equipped with a power cord and a plug or another
device to disconnect the appliance from the power
source must have an allpole disconnecting device
with a contact gap of at least 3 mm installed in the
external installation.
Supply cords used with this unit shall be
oilresistant, sheathed flexible cable, not lighter than
ordinary polychloroprene or other equivalent
synthetic elastomersheathed cord (Code
designation 60245 IEC 57). They must be installed
with the proper cord anchorage to relieve conductors
from strain, including twisting, at the terminals and
protect the insulation of the conductors from
abrasion.
The main power supply(s) to the grill must
be disconnected prior to performing any repairs.
Failure to follow this instruction may result in
personal injury or death from electrical shock or
hazardous moving parts, as well as poor
performance or damage to the equipment.
Note: Grills require electrical power for operation. In
the event of a power outage, place the unit in the
OFF position.
DO NOT install the grill in an area where a
water jet could be used to clean or rinse the grill.
Failure to follow this instruction may result in serious
electrical shock.
Ventilation and Clearance
To ensure proper operation of this appliance, it must
be installed away from all combustible products.
Failure to allow proper clearance and airflow
may cause poor performance, damage to the
machine, or unsafe operating conditions.
After set up, DO NOT store anything on top
of this appliance. Failure to follow this instruction
may result in a fire.
DO NOT store flammable vaporous, liquids,
or combustible material in the vicinity of the grill.
This includes, but is not limited to walls, floors,
partitions, furniture, curtains, and decorations.
Grease Disposal Container
In order to comply with NSF Standard 4
requirements, an appropriate grease disposal
container must be provided. This container is
supplied by the KES, not the Taylor Company.
Environmental Notices
______________________________
If the crossed-out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive for Waste Electric/
Electronic Goods (WEEE) as well as other similar
legislation in effect after August 13, 2005. Therefore,
it must be collected separately after its use is
completed and cannot be disposed of as unsorted
municipal waste.
The user is responsible for returning the product to
the appropriate collection facility, as specified by
your local codes.
For additional information regarding applicable local
laws, please contact the municipal facility and/or
local distributor.

6
Introduction McDonald's Intelligap Grills
150520
Model C832 Specifications
See the data label for exact specifications.
Electrical
Standard is 208/60/3 phase.
Three dedicated electrical connections are required;
two, three phase and one interlock/control single
phase. See electrical chart for proper electrical
requirements. Manufactured to be permanently
connected. Consult your KES or local Taylor
distributor for cord and receptacle specifications as
local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse Size
208/60/3 56 20 120/60/1 7A
240/60/3 48 20 120/60/1 7A
480/60/3 24 20 120/60/1 7A
400/50/3n~ 29 20 230/50/1 4A
Dimensions
Width: 38” (965 mm)
Depth: 37-7/8” (962 mm)
Height : 49-1/2 to 54-1/2” (1257 to 1384 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 3-3/4 to 8-3/4” (96 to 223 mm)
(Casters may be adjusted.)
Approximate Weight
Net: 880 lbs. (399.2 kgs.)
Crated: 924 lbs. (419.1 kgs.)
Volume
54 cu. ft. (1.51 cu. m.)
Figure 1

7
McDonald's Intelligap Grills Introduction
150520
Model C834 Specifications
See the data label for exact specifications.
Electrical
Standard is 400/50/3 phase.
Three dedicated electrical connections are required;
two, three phase and one interlock/control single
phase. See electrical chart for proper electrical
requirements. Manufactured to be permanently
connected. Consult your KES or local Taylor
distributor for cord and receptacle specifications as
local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse
Size
208/60/3 56 20 120/60/1 7A
220/380/60/3 31 20 230/60/1 4A
400/50/3n~4w 29 20 230/50/1 4A
Dimensions
Width: 38” (965 mm)
Depth: 32-3/4” (832 mm)
Height : 49-9/16 to 54-9/16” (1258 to 1385 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 4-1/4 to 9-1/4” (108 to 235 mm)
Approximate Weight
Net: 758 lbs. (343.8 kgs.)
Crated: 872 lbs. (395.5 kgs.)
Volume
53.7 cu. ft. (1.52 cu. m.)
Figure 2

8
Introduction McDonald's Intelligap Grills
150520
Model C835 Specifications
See the data label for exact specifications.
Electrical
Standard is 208/60/3 phase.
Two dedicated electrical connections are required;
one, three phase and one interlock/control single
phase. See the electrical chart for the proper
electrical requirements. Manufactured to be
permanently connected. Consult your KES or local
Taylor distributor for cord and receptacle
specifications as local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse
Size
208/60/3 30 8.4 120/60/1 7A
240/60/3 24 8.4 120/60/1 7A
200/50/60/3 27 8.4 100/60/1 4A
220/380/60/3 14 8.4 220/60/1 4A
220/50/60/3 30 9.0 120/60/1 7A
400/50/3n~ 4w 14 8.4 220/50/1 4A
Gas
Two ceramic infrared burners: 30,000 BTUH each.
Manifold pressure: 3.5” w.c. natural, 10.5” w.c.
propane.
Dimensions
Width: 38” (965 mm)
Depth: 39-3/4” (1010 mm)
Height : 49-9/16 to 54-9/16” (1258 to 1385 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 3-3/8 to 8-3/8” (86 to 213 mm)
(Casters may be adjusted.)
Approximate Weight
Net: 861 lbs. (390.5 kgs.)
Crated: 970 lbs. (440.0 kgs.)
Volume
53.7 cu. ft. (1.52 cu. m.)
Figure 3

9
McDonald's Intelligap Grills Introduction
150520
Model C836 Specifications
See the data label for exact specifications.
Electrical
Two dedicated electrical connections are required.
See the electrical chart for the proper electrical
requirements. Manufactured to be permanently
connected. Consult your KES or local Taylor
distributor for cord and receptacle specifications as
local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse Size
400/50/3n~ 16 8.8 230/50/1 4A
Dimensions
Width: 20” (508 mm)
Depth: 32-5/8” (829 mm)
Height : 48-1/2” to 53-1/2” (1232 to 1359 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 5-5/8 to 10-5/8” (143 to 270 mm)
(Casters may be adjusted.)
Approximate Weight
Net: 386 lbs. (173.7 kgs.)
Crated: 466 lbs. (209.7 kgs.)
Volume
33.1 cu. ft. (0.9 cu. m.)
Figure 4

10
Introduction McDonald's Intelligap Grills
150520
Model C838 Specifications
See the data label for exact specifications.
Electrical
Two dedicated electrical connections are required.
See the electrical chart for the proper electrical
requirements. Manufactured to be permanently
connected. Consult your KES or local Taylor
distributor for cord and receptacle specifications as
local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse
Size
400/50/3n~ 18 9.3 230/50/1 4A
Dimensions
Width: 20” (508 mm)
Depth: 38” (965 mm)
Height : 48-1/2” to 53-1/2” (1232 to 1359 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 5-5/8 to 10-5/8” (143 to 270 mm)
(Casters may be adjusted.)
Approximate Weight
Net: 487 lbs. (219.2 kgs.)
Crated: 567 lbs. (255.2 kgs.)
Volume
33.1 cu. ft. (0.9 cu. m.)
Figure 5

11
McDonald's Intelligap Grills Introduction
150520
Model C842 Specifications
See the data label for exact specifications.
Electrical
Standard is 208/60/3 phase.
Three dedicated electrical connections are required;
two, three phase and one interlock/control single
phase. See electrical chart for proper electrical
requirements. Manufactured to be permanently
connected. Consult your KES or local Taylor
distributor for cord and receptacle specifications as
local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse
Size
208/60/3 69 25 120/60/1 10A
220/50/60/3 66 25 220/50/60/1 10A
220/380/60/3 38 25 220/60/1 10A
400/50/3n~4w 32 22 230/50/1 10A
Dimensions
Depth: 38” (965 mm)
Width: 37-7/8” (962 mm)
Height : 50-1/2 to 55-1/2” (1283 to 1410 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 5-3/16 to 10-3/16”
(132 to 259 mm) (Casters may be adjusted.)
Approximate Weight
Net: 940 lbs. (426.4 kgs.)
Crated: 990 lbs. (449.1 kgs.)
Volume
54 cu. ft. (1.51 cu. m.)
Figure 6

12
Introduction McDonald's Intelligap Grills
150520
Model C844 Specifications
See the data label for exact specifications.
Electrical
Three dedicated electrical connections are required;
two, three phase and one interlock/control single
phase. See electrical chart for proper electrical
requirements. Manufactured to be permanently
connected. Consult your KES or local Taylor
distributor for cord and receptacle specifications as
local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse
Size
208/60/3 63 22.5 120/60/1 7A
220/380/60/3 38 24.9 220/60/1 4A
400/50/3n~ 32 22.0 230/50/1 4A
220/50/60/3 64 24.2 220/50/60/1 7A
Dimensions
Width: 38” (965 mm)
Depth: 34-15/16” (887 mm)
Height : 50-1/2 to 55-1/2” (1283 to 1410 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 5-3/16 to 10-3/16”
(132 to 259 mm) (Casters may be adjusted.)
Approximate Weight
Net: 870 lbs. (394.6 kgs.)
Crated: 945 lbs. (428.6 kgs.)
Volume
53.7 cu. ft. (1.52 cu. m.)
Figure 7

13
McDonald's Intelligap Grills Introduction
150520
Model C845 Specifications
See the data label for exact specifications.
Electrical
Standard is 208/60/3 phase.
Two dedicated electrical connections are required;
one, three phase and one interlock/control single
phase. See the electrical chart for the proper
electrical requirements. Manufactured to be
permanently connected. Consult your KES or local
Taylor distributor for cord and receptacle
specifications as local codes allow.
Electrical Total
Amp
Total
KW
Interlock/
Control
Voltage
Interlock
Fuse
Size
208/60/3 22 7.8 120/60/1 10A
200/50/60/3 23 7.8 100/50/60/1 10A
220/380/60/3 12 7.8 230/60/1 10A
220/50/60/3 20 7.8 220/60/1 10A
400/50/3n~4w 11 7.8 230/50/1 10A
Gas
Three ceramic infrared burners: 25,000 BTUH each.
Manifold pressure: 3.5” w.c. natural, 10.5” w.c.
propane.
Dimensions
Width: 38” (965 mm)
Depth: 38-1/2” (978 mm)
Height : 50-1/2 to 55-1/2” (1283 to 1410 mm)
Cooking Surface Height: 29 to 34” (737 to 864 mm)
Floor Clearance: 3-3/4 to 8-3/4”
(96 to 223 mm) (Casters may be adjusted.)
Approximate Weight
Net: 923 lbs. (418.7 kgs.)
Crated: 1032 lbs. (468.1 kgs.)
Volume
52.6 cu. ft. (1.49 cu. m.)
Figure 8

14
Introduction McDonald's Intelligap Grills
Patty Placement Guides
Placement procedures of meat products must be
followed on the clamshell grill. Meat must be placed
on the lower grill plate two patties at a time, front to
back and right to left. When the cook cycle is
complete, the upper platen will raise.
Note: It is very important that all patties be
removed from the lower grill plate in the same
sequence that they were placed before cooking.
Patties must be removed immediately after the
upper platen has been raised to the OPEN position
and after the meat has been seasoned.
The sandblasted outlines on the lower cook surface
show where product should be placed.
The following charts are to be used as patty
placement guides:
This manual suits for next models
7
Table of contents
Other Taylor Grill manuals

Taylor
Taylor QS12 User manual

Taylor
Taylor QS11 User manual

Taylor
Taylor 811 series User manual

Taylor
Taylor The Biggest Loser AG-1360-BL User manual

Taylor
Taylor The Biggest Loser AG-1350-BL User manual

Taylor
Taylor C801 User manual

Taylor
Taylor The Biggest Loser AG-1300-BL User manual

Taylor
Taylor QS12 User manual

Taylor
Taylor L850 User manual

Taylor
Taylor 810 Series Operating instructions