1. Features
© COPYRIGHT 1992-2007. ALL RIGHTS RESERVED.
TC Communications, Inc. 17881 Cartwright Road - Irvine, CA 92614
Tel: (949) 852-1972 Fax: (949) 852-1948 Web Site: www.tccomm.com Email: info@tccomm.com
3. Description
Featuring distances up to 80km, the TC3705 10/100Base-T Ethernet Fiber Optic Switch provides a 100Base-
FX port that combines Ethernet Switching and Fiber Optic technology to boost total network bandwidth.
The TC3705 offers one multimode (1300nm) or single mode (1300/1550nm) optical port and four Ethernet
10/100Base-T Auto-Sensing/Auto-Negotiation switched ports. Each of these ports supports either 10Base-
T or 100Base-TX. There are two optional versions (Model TC3705T) for extreme temperature applications
(-20C to 70C, -40C to 80C).
Because it functions like an Ethernet bridge (connects multiple Ethernet segments to prevent unnecessary
network traffic), it creates an efficient sub-divided switched LAN that provides full and transparent
bandwidth for each segment.
The TC3705’s modern switching technology eliminates the congestion problem inherent to the contention-
oriented Ethernet CSMA/CD protocol. This improves predictable response times under heavy network
loads. Previously, expensive routing technology was used to alleviate congestion from heavy traffic
loads.Power is 12VDC, optional 24VDC, -48VDC, 125VDC, or 115/230VAC with an external power cube.
Units are standalone or 19" rack mountable. Optical connectors can be SC, ST or FC.
4. Electrical Specifications
Data Rates: 10Mbps/100Mbps auto negotiation
Connectors: RJ-45 Female
5. Temperature
Operating..............................................................................................................................-10oC to 50oC
IEEE 802.3, 802.3u, and 802.3x
2. Standards
4 Ethernet 10/100Base-T Auto-Sensing Twisted Pair Ports with RJ-45 Connectors
1 Fiber Optic 100Base-FX Port
MDI/MDIX Auto Detection and Operation on Twisted Pair Ports
Full or Half Duplex Transfer Mode for each Twisted Pair Ports
Multimode (1310nm) and Single Mode (1310nm/1550nm)
Distances up to 80km
Hardened Temperature (optional), -40°C to 80°C
Standalone or Rackmount
Alarm Relay

−2−
TC3705 User's Manual
Rev. 1.2
6. Optical Specifications
Multimode Model
Transmitter: LED; typical Launch Power: -17.0 dBm* (1310nm, @62.5/125µm)
Receiver: PIN Diode; typical Sensitivity: -33.0 dBm* (1310nm, @62.5/125µm)
Optic saturation level: -11.0 dBm*(1310nm, @62.5/125µm
Loss Budget: 1310nm Multimode @62.5/125µm: 15 dB
Distance: 1310nm Multimode, @62.5/125µm: up to 4km distance*
Wavelength: 1310nm Multimode:
Connector: SC
ST
Single Mode 1310nm, 20km Model
Transmitter: FP Laser; typical Launch Power: -15 to -7 dBm* (1310nm, @9/125µm)
Receiver: PIN Diode; typical Sensitivity: -34.0 dBm* (1310nm, @9/125µm)
Optic saturation level: -3 dBm*(1310nm, @9/125µm)
Loss Budget: 1310nm Single Mode, @9/125µm: 19 dB
Distance: 1310nm Single Mode, @9/125µm: up to 20 km distance
Wavelength: 1310nm Single Mode(LASER):
Connector: ST
FC
SC
Single Mode 1310nm, 75km Model
Transmitter: FP Laser; typical Launch Power: -3 to +2dBm* (1310nm, @9/125µm)
Receiver: PIN Diode; typical Sensitivity: -36.0 dBm* (1310nm, @9/125µm)
Optic saturation level: -3 dBm* (1310nm, @9/125µm)
Loss Budget: 1310nm Single Mode, @9/125µm: 33dB
Distance: 1310nm Single Mode, @9/125µm: up to 75km distance
Wavelength: 1310nm Single Mode (LASER)
Connector: ST
FC
SC
Single Mode 1550nm, 75km Model
Transmitter: DFB Laser; typical Launch Power: -10 to -1dBm* (1550nm, @9/125µm)
Receiver: PIN Diode; typical Sensitivity: -34.0 dBm* (1550nm, @9/125µm)
Optic saturation level: 0 dBm* (1550nm, @9/125µm)
Loss Budget: 1550nm Single Mode, @9/125µm: 24dB
Distance: 1550nm Single Mode, @9/125µm: up to 75km distance
Wavelength: 1550nm Single Mode (LASER)
Connector: ST
FC
SC

−3−
TC3705 User's Manual
Rev. 1.2
Single Fiber, 50km Model
Transmitter: Typical Launch Power: -8 to -3 dBm* (1310nm/1550nm, @9/125µm)
Receiver: PIN Diode; typical Sensitivity: -33.0 dBm* (1310nm/1550nm, @9/125µm)
Optic saturation level: -3 dBm*
Loss Budget: 1310nm/1550nm Single Mode, @9/125µm: 29 dB
Distance: 1310nm/1550nm Single Mode, @9/125µm: up to 50km distance
Wavelength: 1310nm/1550nm Single Mode:
Connector: SC Only

−4−
TC3705 User's Manual
Rev. 1.2
7. Connectors and LED Indicators
Figure 1. TC3705's Front Panel
Figure 2. TC3705's Rear Panel
+ -
+ -
DryContactRelay
(NormalOpen)
Redundantpowersupply
input.Onlyonepowersupply
isneeded.
FourRJ-4510/100MbpsPorts
forthetwistedpairconnection.
LEDStatusIndicatorsfor
TwistedPairPorts1through4:
100M
FULL/COL FullDuplex/Collision
IndicatorLED:
LINK/ACT
- when the Twisted Pair
portisoperatingat100Mbps.
- whentheTwistedPairportis
operatingat10Mbps.
-
-“ whentheportisoperating
at full duplex.
-
-“ whencollisionsoccur.
-“ whentheTwisted
Pairporthasestablishedavalidlink.
-
S o l i d l y l i t
“ O f f ”
Solidly lit”
B l i n k i n g ”
Solidlylit”
“ B l i n k i n g ”
“ O f f ”
whentheportisoperating
athalfduplex.
whenthereisEthernetActivity.
LEDStatusIndicators
for FiberOpticChannel:
100M
FULL/COL FullDuplex/Collision
IndicatorLED:
LINK/ACT
-
-
-
- whenthefiberopticport
hasestablishedavalidopticallink.
- when the optical fibers
arenotconnected.
-
A l w a y s l i t .
A l w a y s l i t .
S o l i d l y l i t
“Off ”
“ B l i n k i n g ”
whenEthernetActivity
atthefiberopticportisdetected.
L E D I n d i c a t o r s f o r :
P o w e r A , P o w e r B
and5Vvoltageregulated
f r o m p o w e r A a n d p o w e r B .
P r i m a r y o p t i c
ReceiverandTransmiter

−5−
TC3705 User's Manual
Rev. 1.2
8. Typical Application Diagram
The TC3705 10/100Mbps Ethernet Switch is a low cost and flexible solution to extend a local area network
to a remote site through fiber optic cables. Providing bandwidth solution to efficiently handle the traffic
between the local and the remote workgroups of the network and reducing the need of expensive routers
that usually cater to the network backbone.
This application diagram shows a network connection between two LANs. Extend PC lines from a server
over fiber or have a telephone "hotlink" using our TC1910's as shown on the diagram. By connecting two
TC1910's to the Twisted Pair ports and using regular telephone sets, the users at both sides of the fiber link
can have a hotlink phone line setup. When one user lift up the handset, the remote side phone will start to
ring. When remote side user pickup the handset, the phone stop to ring and the conversation begins.
Figure 3. Typical Application Diagram for the TC3705's
M u l t i m o d e o r S i n g l e M o d e
Fiber Optic Cables
T y p i c a l a p p l i c a t i o n u s i n g T C 3 7 0 5 E t h e r n e t F i b e r O p t i c S w i t c h e s c o n n e c t i n g t w o L A N s .

−6−
TC3705 User's Manual
Rev. 1.2
You can use the TC3705's for a variety of network configurations. For example, connect up to four hubs or
switches to develop workgroups with dedicated 10/100Mbps links. Connect your routers, printers, servers,
and other network devices.
9. Hub Topology Diagram
Figure 4. Backbone Using an Extended Star Topology with the TC3705's
Multimode or Single Mode
Fiber Optic Cables

−7−
TC3705 User's Manual
Rev. 1.2
10. Power Requirements
A. The TC3705's input voltage is 12V DC and current is 600mA.
B. The TC3705's power connectors are two terminal blocks located on the rear panel of the unit. Polarity
is indicated on each connector block (see Figure 2).
C. Should an external power adapter need to be replaced, use one with the following specifications: 12V
DC @600mA. You may order it directly from TC Communications.
D. The TC3705 can also be ordered with an optional 24 VDC, 48 VDC or power supply. Current
consumption at 24VDC is 300mA, at 48VDC is 150mA, and at 125VDC is 60mA.
11. System Start Up
1. Apply the power by plugging the power plug into any power jack on the rear panel. The power source
can be from a power adapter or from a power card (installed either on the left or right side of the rack).
2. The "PWR A" or "PWR B" LEDs on the front panel will light according to which power jack (A or B)
is connected. Both LEDs will light when power redundancy is utilized.
3. The "Vcc" LED should also light, indicating an adequate operating voltage is being derived from the
power source.
4. Connect the twisted pair cables to the RJ-45 connectors on the rear panel of the switches. If the twisted
pair cables are providing an Ethernet signal, then the corresponding front LEDs for that particular
channel will light as follows:
a). If 100Mbps full duplex is detected bythe switch, the 100M & FULL/COL LEDs will be solidly lit and
the LINK/ACT will blink as activity is detected.
b). If 10Mbps full duplex is detected by the switch, the 100M LED will be "Off" and the FULL/COL
LED will be lit.
c). If half duplex and collisions are detected by the switch, the FULL/COL LED will be blinking.
5. Connect the optical fibers from the Tx connector of one unit to the Rx connector of the second unit, the
LINK/ACT LED of the fiber port on the second unit will be solidly lit. Do the same for the second pair
of Rx to Tx connectors and observed the LINK/ACT LED on the first unit will be lit.
7. When communication is established and traffic passes through the fiber between two TC3705's the
LINK/ACT LED will blink.

−8−
TC3705 User's Manual
Rev. 1.2
12. Dry Contact Relay Alarm (optional)
A terminal block connector on the rear panel (labeled "ALARM")
provides for the optional dry contact relay alarm (see Figure 2).
Normally in the OPEN position, any loss of optical signal will
trigger an alarm condition and force the switch to the CLOSED
position. This relay can be used in conjunction with an external
device to monitor the condition of the fiber optic links.
Dry Contact Alarm Condition:
When the front panel LINK/ACT LED is lit and/or blinking, the TC3705 is working well and thus it is not
in Alarm Condition. Otherwise, if the LINK/ACT LED is "Off" the TC3705 will be in Alarm Condition and
the Dry Contact Relay will be activated.
13. Physical Characteristics
Height: 1.4" (3.53 cm) Depth: 6.5" (16.57 cm)
Width: 7.1" (18.14 cm) Weight: 1.2 lbs. (544 gm)
14. Troubleshooting
Power Problem:
No LEDs are lit:
A. "PWRA" and/or "PWRB" LEDs should be on when power is connected. If both are "Off," then no DC
power is reaching the unit. Check the power supply, source, and polarity.
B. If "PWRA" and/or "PWRB" LEDs are "On" but all other LEDs are "Off", and the Alarm switch is not
closed, it indicates an internal problem with the unit. For assistance, please contact the Technical Support
Department at TC Communications @ (949) 852-1973.
Electrical Problem:
If All LEDs, 100M, FULL/COL, and LINK/ACT, are OFF:
It means that there is no ethernet electrical signal detected by the TC3705. Check the twisted pair cables
for good connectivity. Make sure that the units have adequate power.
Optical Problem:
If the 100M and FULL/COL LEDs are lit, and the LINK/ACT LED is OFF:
A. Check the physical fiber optic cable connection to make sure it is not loose or broken.
B. Optic "Tx" is connected wrongly to another TC3705's "Tx."
C. Optic cable type is incorrect. Typically, fiber optic cable with yellow-colored insulation is designated for
Single Mode use @8.2µm or 9µm; orange or gray-colored cable is for Multimode use @50µm or 62µm.
If the wrong cable type is used, the unit will not function properly.
15. Frequently Asked Questions
1) What kind of Ethernet cable should I use?
Ans: Use RJ-45 standard CAT. 5 or 5E Ethernet cable. Because all twisted pair ports on the
TC3705 are MDI/MDIX Auto-Detection and Operation, you can use either straight
through(patch cable) or cross-over cable.

−9−
TC3705 User's Manual
Rev. 1.2
16. Warranty & Return Policy
Return Policy
To return a product, you must first obtain a Return Material Authorization number from the Customer
Service Department. If the product’s warranty has expired, you will need to provide a purchase order to
authorize the repair. When returning a product for a suspected failure, please provide a description of the
problem and any results of diagnostic tests that have been conducted.
Warranty
Damages by lightning or power surges are not covered under this warranty.
All products manufactured by TC Communications, Inc. come with a five year (beginning 1-1-02)
warranty. TC Communications, Inc. warrants to the Buyer that all goods sold will perform in accordance
with the applicable data sheets, drawings or written specifications. It also warrants that, at the time of sale,
the goods will be free from defects in material or workmanship. This warranty shall apply for a period of
five years from the date of shipment, unless goods have been subject to misuse, neglect, altered or destroyed
serial number labels, accidents (damages caused in whole or in part to accident, lightning, power surge,
floods, fires, earthquakes, natural disasters, or Acts of God.), improper installation or maintenance, or
alteration or repair by anyone other than Seller or its authorized representative.
Buyer should notify TC Communications, Inc. promptly in writing of any claim based upon warranty, and
TC Communications, Inc., at its option, may first inspect such goods at the premises of the Buyer, or may
give written authorization to Buyer to return the goods to TC Communications, Inc., transportation charges
prepaid, for examination by TC Communications, Inc. Buyer shall bear the risk of loss until all goods
authorized to be returned are delivered to TC Communications, Inc. TC Communications, Inc. shall not be
liable for any inspection, packing or labor costs in connection with the return of goods.
In the event that TC Communications, Inc. breaches its obligation of warranty, the sole and exclusive
remedy of the Buyer is limited to replacement, repair or credit of the purchase price, at TC Communications,
Inc.’s option.
To return a product, you must first obtain a Return Material Authorization (RMA) number and RMA form
from the Customer Service Department. If the product’s warranty has expired, you will need to provide a
purchase order to authorize the repair. When returning a product for a suspected failure, please fill out RMA
form provided with a description of the problem(s) and any results of diagnostic tests that have been
conducted. The shipping expense to TC Communications should be prepaid. The product should be properly
packaged and insured. After the product is repaired, TC Communications will ship the product back to the
shipper at TC's cost to U.S. domestic destinations. (Foreign customers are responsible for all shipping costs,
duties and taxes [both ways]. We will reject any packages with airway bill indicating TC communications
is responsible for Duties and Taxes. To avoid Customs Duties and Taxes, please include proper documents
indicating the product(s) are returned for repair/retest).
Table of contents
Other TC Communications Switch manuals
Popular Switch manuals by other brands

HP
HP ProCurve 1600M installation guide

Avenview
Avenview SW-HDM3D-C5-4X4 user guide

Siemens
Siemens RUGGEDCOM RSG2200 installation guide

Mellanox Technologies
Mellanox Technologies SX6710 Hardware user manual

ADLINK Technology
ADLINK Technology cPCI-6S10 Series user manual

Zte
Zte ZXR10 8900 Series user manual