TC Electronic TouchMonitor TM7 User manual

TM7/TM9
TouchMonitor
USER‘S MANUAL
Platform engineered and designed by in Germany
EN

EN-2 Manual TouchMonitor TM7/TM9
User‘s Manual
for
TC TouchMonitor TM7/TM9
Manual Version: 2.0
Issued: 15.09.2011
Software-Version:2-nn (09.2011)
© 09/2011. Technical changes without prior notice!
TC Electronic A/S, Sindalsvej 34, DK-8240 Risskov, Denmark,
www.tcelectronic.com, [email protected]
RTW GmbH & Co.KG, Elbeallee 19, 50765 Köln, Germany,
www.rtw.de, rtw@rtw.de
WEEE Reg.-no.: DE 90666819
Category: 9
Device type: These instruments comply with and fall under
category 9 Monitoring and control equipment of
Annex 1B of the RoHS-Directive 2002/95/EC.
Please note:
The gures in this operating manual are carefully created and
are used to illustrate the descriptions. However, they may differ
a little bit from the displays of your unit.
This manual and the available rmware/rmware updates can
be found on our web site:
http://www.tcelectronic.com/touchmonitor-support.asp.
The package contains a USB ash device soruce by a third
party company. The device is certied by Shenzhen BSE Tech-
nology Co., Ltd. to be CE conform (E07002566) and RoHS
compliant (R0808179).

EN-3Manual | TouchMonitor TM7/TM9 Safety Instructions
EN
Safety Instructions
The following symbols may be marked on the panels or covers of
equipment or module and are used in this manuals with these terms:
WARNING!
This symbol alerts you to a potentially hazardous condition, such as
the presence of dangerous voltage that could pose a risk of electrical
shock. Refer to the accompanying Warning Label or Tag, and exercise
extreme caution.
ATTENTION!
This symbol alerts you to important operating considerations or a po-
tential operating condition that could damage equipment. If you see
this marked on equipment, consult the Operating manual for precauti-
onary instructions.
NOTE
This symbol points your attention to specific characteristics that are
no malfunctions.
General Safety Instructions
• Studycarefullyandunderstandallsafetyandoperatinginstruc-
tions before you install and operate the unit!
• Heedallwarningsontheunitandinthesafetyandoperatinginst-
ructions before you install and operate the unit!
• Alwaysfollowtheseinstructionstoensureagainstinjurytoyour-
selfanddamagetotheunitorotherobjectsconnectedtotheunit.
• Keepallsafetyandoperatinginstructionsforfuturereference!
Topreventpossibleelectricalshock,death,re,injuriesandmalfunc-
tions, use this product only as specified.
The units of the TouchMonitor series are designed for indoor use only
and may only be operated with a power supply unit provided for it.

Safety InstructionsEN-4 Manual | TouchMonitor TM7/TM9
WARNING!
Alwaysfollowthesafetyprecautionsbelowtoavoidthepossibilityofseriousinjuryorevendeathfromelectricalshock,short-circuiting,dama-
ges, fire, or other hazards. These precautions include, but are not limited to, the following:
• Avoidexposedcircuitry.Donottouchexposedconnectionsand
components when power is present.
• Powerdisconnect.Thepowercordoftheexternalpowersupply
disconnectstheproductfromthepowersource.Donotblockthe
power cord or power supply; it must remain accessible to the user
at any time.
• Turnoffanddisconnectthepowersupplyimmediatelyittheunit
produces unusual smells, noises or smoke, or if foreign substan-
ces(e.g.liquids)orforeignobjectsentertheunit.
• Donotcovertheunitanddonotplaceanyobjectsoranything
containing liquids on it.
• Donotinsertyourngersoranyotherobjectsintothehousing.
• Donotoperatewithoutcoverplatesorpanels.
• Donotoperatewithsuspectedfailures.Ifyoususpectthereisda-
mage to the unit, have it inspected by qualified service personnel.
• Donotoperateinwet/dampconditions.
• Donotoperateinexplosiveatmosphere.
• Donotoperateindustyenvironments.
• Donotopenthehousing.Inside,therearenouser-serviceable
parts.Anynecessaryservicingshallbeperformedbyaproperly
qualified technician.
• Donotattempttorepairanypartoftheunit.Repairsshallonlybe
carried out by qualified personnel.
• Neverremoveanypartsfromtheunitanddonotmakeanymodi-
fications to the unit without the express written consent of RTW.
Modifications can cause both safety hazards and affect the unit’s
EMI-CE conformity.
• Onlyusethepowercordandpowersupplyspeciedforthispro-
duct and certified for the country of use.
• Connectanddisconnectproperly.Useonlyconnectorsspecied
for this product and fix them tight before use.
• Observeallterminalratingsandmarkingsontheproduct.Consult
the operating manual for further ratings information before making
connections to this product.
• Donotapplyapotentialtoanyterminalthatexceedsthemaxi-
mum rating of that terminal.

EN-5Manual | TouchMonitor TM7/TM9 Safety Instructions
EN
ATTENTION!
Alwaysfollowthesafetyprecautionsbelowtoavoidthepossibilityofphysicalinjurytoyouorothers,ordamagetotheunitorotherproperty.
These precautions include, but are not limited to, the following:
• Donotoperatetheunitwithoutadequateventilationtopreventthe
internal temperature from becoming too high.
• Thereforealsokeepawaytheunitfromdirectincidentsolar
radiation
• Keepproductsurfacescleananddry.Onlyuseadrycloth.
• Neveruseanysolventbasedliquidsforcleaningthehousing
surfaces and the display.
• Donotplacetheunitinanunstablepositionwhereitmight
accidently fall over.
• Beforeconnectinganydevicestotheunitmakesurethatthe
power supply is disconnected.
• Beforemovingtheunit,removeallconnectedcables.
• Whentransportingormovingtheunit,alwaystakecarenotto
scratch or damage the housing surfaces and the display.

Environmental ConsiderationsEN-6 Manual | TouchMonitor TM7/TM9
Environmental Considerations
Observe the following information about the environmental impact
of the product and the following guidelines when recycling an instru-
ment or component (product end-of-life handling):
• EquipmentRecycling.
Productionofthisequipmentrequiredtheextractionanduseof
natural resources. The equipment may contain substances that
could be harmful to the environment or human health if improperly
handled at the product’s end of life. In order to avoid release of
such substances into the environment and to reduce the use of
natural resources, we encourage you to recycle this product in an
appropriate system that will ensure that most of the materials are
reused or recycled appropriately.
• BatteryRecycling.
ThisproductmaycontainaNickelCadmium(NiCd)orlithiumion
(Li-ion) rechargeable battery, which must be recycled or disposed
ofproperly.Pleaseproperlydisposeoforrecyclethebatteryac-
cording to your local government regulations.
• RestrictionofHazardousSubstances
This product has been classified as Monitoring and Control equip-
ment,andisoutsidethescopeofthe2002/95/ECRoHSDirec-
tive.Thisproductmaycontainlead,cadmiumand/ormercuryin
slightquantities.Pleasedisposeoforrecycletheelectronicparts
or devices according to your local government regulations.

EN-7Manual | TouchMonitor TM7/TM9 Index of Content
EN
Index of Content
Safety Instructions 3
General Safety Instructions 3
Warning! 4
Attention!5
EnvironmentalConsiderations6
IndexofContent7
BeforeYouBegin9
Introduction 9
ScopeofDelivery11
Installation 13
Connection14
PinAssignment15
GettingStarted17
SystemStart-up17
AdapttheTouchMonitortoyourAudioSystem18
CreateYourOwnPreset20
WorkingwithInstrumentsandPresets25
SoftwareModules(LicencesHandling)27
SoftwareUpdate31
Specications(Extract)33
ECDeclarationofConformity35
LicensesoftheImplementedSoftware36

EN-8 Manual | TouchMonitor TM7/TM9

EN-9Manual | TouchMonitor TM7/TM9 Before You Begin | Introduction
EN
BeforeYouBegin
Introduction
Thank you for purchasing a model of the TouchMonitor series. With
the TouchMonitor range you are able to meet the growing require-
ments in today‘s production, post-production, and broadcast world.
Equippedwithhigh-grade7“or9“touchscreensandaneasy-to-use
GUI,TouchMonitorentersanewlevelofprofessionalaudiometering
in terms of precision, performance, efficiency and flexibility.

Before You Begin | IntroductionEN-10 Manual | TouchMonitor TM7/TM9
Simpleandexible
The graphical user interface used in the TouchMonitor range is con-
trolled simply by using your finger or a mouse. Instruments can be
scaled, randomly positioned and combined in almost every way for
optimized use of available screen space. Even multiple instruments of
the same type, assigned to different input channels and configurations,
canbedisplayedsimultaneously.Acontext-sensitive,on-screenhelp
feature and the intuitive operatable menu system supports the user,
allowing him to make setup changes with ease.
AudioI/Ooptions
The TouchMonitor perfectly integrates into today‘s analog and digital
audio and video studio environments. It handles input signals of vari-
ousformats:analog,AES3,andAES3id.Inaddition,theTouchMonitor
TM9hasanoptiontoaccept3GSDIsignals.Thisoptionworksasan
audio deembedder for mixed use with other audio interfaces display-
ing up to 32 input channels simultaneously.
Licences
Atotallymodularsoftwareconceptmeansthatyouonlyhaveto
purchase features that you actually require. This puts you in control,
defining the functionality of a TouchMonitor that suits your needs
best.Newinstrumentsandfunctionscanbeaddedassoftware
modules to the device at any time. Simply purchase and activate the
corresponding licence.
Many display functions are available to choose from: the unique RTW
SurroundSoundAnalyzer,theReal-TimeAnalyzer(RTA),EBUR128-,
ITUBS.1770/1771-,ATSC-A/85-,andARIB-compliantloudness
meters, and the Radar Loudness display acc. to the Loudness Radar
Meter of TC electronic®.

EN-11Manual | TouchMonitor TM7/TM9 Before You Begin | Scope of Delivery
EN
ScopeofDelivery
Unpacktheinstrument,ndyourversionbelow,andcheck,ifyoureceivedallitemslisted.Ifcomponentsaremissing,pleasecontactyour
dealer. Recommended accessories, options and software licences are also listed.
TouchMonitorTM7
Table-top unit 20700 Powersupply Quick Start Guide
Multichannel
mode
SW20001
Loudness and
SPLdisplay
SW20002
RTA-RealTime
Analyzer
SW20003
SSA-Surround
SoundAnalyzer
SW20004
RadarDisplay
SW20005
PremiumPPM
+ Vectorscope
SW20006
8xAES3
8 x analog
HW20711
8xAES3id
8 x analog
HW20712
> >
AudioInterfaceasordered SoftwareLicence,ifordered
> >
USBstick

Before You Begin | Scope of DeliveryEN-12 Manual | TouchMonitor TM7/TM9
TouchMonitorTM9
Table-topunit20900 Powersupply Quick Start Guide
Multichannel
mode
SW20001
Loudness and
SPLdisplay
SW20002
RTA-RealTime
Analyzer
SW20003
SSA-Surround
SoundAnalyzer
SW20004
RadarDisplay
SW20005
PremiumPPM
+ Vectorscope
SW20006
8xAES3
8 x analog
HW20911
> >
AudioInterfaceasordered SoftwareLicence,ifordered
> >
USBstick
8xAES3id
8 x analog
HW20912
16xAES3
HW20913
16xAES3id
HW20914
16xanalog
HW20915
3G-SDI
option
HW20930

EN-13Manual | TouchMonitor TM7/TM9 Installation
EN
Installation
TheTouchMonitorTM7andTM9table-topunits(20700/20900)are
designed for free positioning on tables, desks, et. al.
Allnecessarypowersupplyvoltagesaresuppliedthroughthe+24V
DC1Aconnectorusinganexternalpowersupplyunit(suchasthe
RTW1168-Rwidevoltagepowersupply,includedin20700and
20900packages).Theunitsfeaturea7“resp.9“VGA16:9touch
screen.
Optionalanexternalstandard16:9VGAmonitorcanbeconnected
for external reading of the display.
Optional an external computer mouse or a Wacom® graphics tablet
canbeconnectedtooneoftheUSBinterfaces.
The other ports and interfaces are connected with the appropriate
standard connection cables.
ATTENTION–Pleasereadbeforeinstalling:
• Beforeinstallingtheunitpleasestudythesafetyinstructionsand
the information on connection and pin assignment.
• Anexternalovercurrentprotectivedevice(2Amax.)shallbe
installedwhenusinganexternal24VDCpowersupply!
• Makesurethattheadaptedpowersupplyunitisnotconnected.
• Connectyoursignalsourcesandallyourothercomponentstothe
appropriate connectors, using the correct standard connection
cables for the components. Take care about the pin assignment!
• Optionally,connectanexternalstandard16:9VGAmonitorto
theVGAoutput,usingastandardVGAconnectioncable.TheVGA
cableshallbeof10to15mmaximumlength.
• Finally,connectthelocking4-pinlowvoltageconnectorofthe
externalpowersupplytothe+24VDC1Aconnectorontherear.
Connect the external power supply to mains.
• TheTouchMonitorwillinitiateitssystemstartupsequence.After
the boot-up the unit is ready for use.

Installation | ConnectionEN-14 Manual | TouchMonitor TM7/TM9
Analog In 1 - 8
(Sub-D)
AES3id In/Out 1 - 4
(8 x BNC)
AES3 In/Out 5 - 8
(Sub-D)
AES3id In/Out 5 - 8
(8 x BNC)
Analog In 9 - 16
(Sub-D)
GP IO
(RJ-11)
AES3 In/Out 1 - 4
(Sub-D)
Analog In 1 - 8
(Sub-D)
AES3 In/Out 1 - 4
(Sub-D)
AES3id In/Out 1 - 4
(8 x BNC)
Analog In 1 - 8
(Sub-D)
LAN
(RJ-45)
USB A 2.0
(Full Speed)
4-pin locking
low voltage
connector
External:
USB mouse
Wacom® graphics tablet
External:
VGA monitor 16 : 9
24 V DC, 1 A3G-SDI: In Through VGA
HW20911
(pictured):
HW20912:
HW20913:
HW20914:
HW20915:
Optional:
3G-SDI interface
option
HW20930
or
Connection
or
TouchMonitorTM9TouchMonitorTM7
4-pin locking
low voltage
connector
External:
VGA monitor 16 : 9
24 V DC, 1 A
VGA
Analog In 1 - 8
(Sub-D)
Analog In 1 - 8
(Sub-D)
GP IO
(RJ-11)
AES3 In/Out 1 - 4
(Sub-D)
AES3id In/Out 1 - 4
(8 x BNC)
LAN
(RJ-45)
USB A 2.0
(Full Speed)
External:
USB mouse
Wacom® graphics tablet
HW20711
(pictured):
HW20712:
or

EN-15Manual | TouchMonitor TM7/TM9 Installation | Pin Assignment
EN
PinAssignment
AnalogIn1-8,AnalogIn9-16(electronicallybalanced,25-pinSub-D-F)
Pin: Function:
1 Inputanalog8resp.16(+,hot)
14 Inputanalog8resp.16(–,cold)
2 Shield/case
15 Inputanalog7resp.15(+,hot)
3 Inputanalog7resp.15(–,cold)
16 Shield/case
4 Inputanalog6resp.14(+,hot)
17 Inputanalog6resp.14(–,cold)
5 Shield/case
18 Inputanalog5resp.13(+,hot)
6 Inputanalog5resp.13(–,cold)
19 Shield/case
7 Inputanalog4resp.12(+,hot)
20 Inputanalog4resp.12(–,cold)
8 Shield/case
21 Inputanalog3resp.11(+,hot)
9 Inputanalog3resp.11(–,cold)
22 Shield/case
10 Inputanalog2resp.10(+,hot)
23 Inputanalog2resp.10(–,cold)
11 Shield/case
24 Inputanalog1resp.9(+,hot)
12 Inputanalog1resp.9(–,cold)
25 Shield/case
13 notused
(External view of the con-
nector)
AES3I/O1-4,AES3I/O5-8(transformerbalanced,25-pinSub-D-F)
Pin: Function:
1 Outputdigital4resp.8(+,hot)
14 Outputdigital4resp.8(–,cold)
2 Shield/case
15 Outputdigital3resp.7(+,hot)
3 Outputdigital3resp.7(–,cold)
16 Shield/case
4 Output digital 2 resp. 6 (+, hot)
17 Outputdigital2resp.6(–,cold)
5 Shield/case
18 Outputdigital1resp.5(+,hot)
6 Outputdigital1bzw.5(–,cold)
19 Shield/case
7 Input digital 4 resp. 8 (+, hot)
20 Inputdigital4resp.8(–,cold)
8 Shield/case
21 Inputdigital3resp.7(+,hot)
9 Inputdigital3resp.7(–,cold)
22 Shield/case
10 Inputdigital2resp.6(+,hot)
23 Inputdigital2resp.6(–,cold)
11 Shield/case
24 Inputdigital1resp.5(+,hot)
12 Inputdigital1resp.5(–,cold)
25 Shield/case
13 notused
NOTE- TheAES3inputsarepermanentlyterminatedwith110Ohm.
(External view of the con-
nector)

Installation | Pin AssignmentEN-16 Manual | TouchMonitor TM7/TM9
PinAssignment(continued)
24V-1A (4-pinlockinglowvoltageconnector,TypBinder710)
Pin: Function:
1-2 +24VDC
3 - 4 0 V
NOTE - Anexternalovercurrentprotectivedevice(2Amax.)shallbe
installedwhenusinganexternal24VDCpowersupply!
GP IO (RJ-116P6Csocket)
ExternalcontroloffunctionsdenedintheGlobalKeyboardmenu.
Pin: Function:
1 GND
2-6 Functionacc.todenitioninthemenu
Pin2
Pin1
Pin3
Pin4
(External view of the connector)
AES3idIn/Out1-4,AES3idIn/Out5-8(unbalanced,BNC-F)
(External view of
the connector)
Pin: Function:
Pin: Signal
Ring: Shield/case
NOTE -TheAES3idinputsarepermanentlyterminatedwith75Ohm.
USB-A
2FullSpeedUSB2.0interfacesfortheconnectionofUSBsticks(Licencehand-
ling, presets, updates) and an external mouse or Wacom® tablet
VGA(15-pinSub-D-F)
Pin: Function:
1 R |Videosignal
2 G |
3 B |
4-8 GND
9 +5V
10-11 GND
12 SDA
13 H-sync
14 V-sync
15 SCI
NOTE -The VGA cable shell not exceed 10 to 15 lenght!
LAN
RJ-45standardnetworkconnector(10/100MBit)
(External view of the connector)
(External view of
the connector)

EN-17Manual | TouchMonitor TM7/TM9 Getting Started | System Start-up
EN
Getting Started
SystemStart-up
BeforeconnectingtheTouchMonitortothepowersupply,please
make sure, that the following connections are made according to
your individual needs:
• Analogand/ordigitalaudioinputsignals
• Digitaloutputs
• Optionalexternalstandard16:9VGAmonitor
• OptionalUSBmouse
• LAN/Ethernet
• Powersupply
When the TouchMonitor is connected to the power supply, it will ini-
tiateitssystemstartupsequence.Aftertheboot-uptheunitisready
for use.
We assume that you are starting your TouchMonitor for the first time.
You now should make some global settings to adopt the unit to your
audiosystem.Afterthisshortprocedureyoucancreateyourrstpre-
set to work with.

Getting Started | Adapt the TouchMonitor to your Audio SystemEN-18 Manual | TouchMonitor TM7/TM9
4.
5.
AdapttheTouchMonitortoyourAudioSystem
The description below leads you through the main steps of the global settings to configure the TouchMonitor once for the use with your audio
system. These settings are not altered by loading new presets.
1. Ifnotvisible,touchtheemptyspaceofthescreentodisplaythe
control bar.
1.
2.
3.
2. Touch the Menu key in the right section of the control bar to
access the menu system showing the Main Menu.
4. If needed, touch Language and select your language in the right
half of the menu. The selection will be shown on the Language key.
4.
3. Touch the System key. This will access the SystemMenu. The
General sub menu will be active (marked in the control bar).
5. TouchtheAudio button in the left section of the control bar to
open the Audio sub menu.

EN-19Manual | TouchMonitor TM7/TM9 Getting Started | Adapt the TouchMonitor to your Audio System
EN
6. If your TM unit should use a defined reference source, touch the
Sync Reference key and select from the items in the right half of
the menu.
7. Touch the Clock key, if you want to set the current date and time.
Start the internal clock with touching the Settime key.
6.
8. Touch the Save key to store your global settings. The unit turns
back to normal display mode.
7.
8.

Getting Started | Create Your Own PresetEN-20 Manual | TouchMonitor TM7/TM9
CreateYourOwnPreset
Presetsareusedtodeneandeditallthespecicsettingsforyour
work flow. So you can create audio groups containing a defined
signal source selection and one or more instruments sharing this do-
mainandshowingparametersofaudiosignals.Alsoyoucancreate
non-audio groups containing intruments, that are not related to audio
input signals, like clock, hardware status monitor, or global keyboard.
If you want to create a preset from scratch, please proceed as follows:
1. Ifnotvisible,touchtheemptyspaceofthescreentodisplaythe
control bar.
2. Touch the Menu key in the right section of the control bar to
access the menu system starting with the Main Menu.
3. Touch the PresetManagement key. The Internal Presets menu
appears.
4. Touch the Newbuttontocreateanewpreset.Apresetwithan
editabledefaultnameiscreated(seenextgure,touchPreset
Nametoedit).
3.
4.
Other manuals for TouchMonitor TM7
1
This manual suits for next models
1
Table of contents
Popular Touch Panel manuals by other brands

Philips
Philips 24BDL4151T quick start

AMX
AMX Modero NXD/NXT-1200VG Operation/reference guide

Renu Electronics
Renu Electronics WP6101TN Plus quick start guide

Winmate
Winmate R15IE3S-PTC3 user guide

TECOM
TECOM TS1001 installation manual

Cardinal
Cardinal 190 Series Installation, Technical and Operation Manual