RKY 1500W
・All specifications are subject to change without notice.
2
RKY
ITEMS/UNIT MODEL RKY24-50R RKY36-42R RKY48-32R
Input
Voltage Range (Nominal: 100-240VAC)
V AC170-265
Frequency
(Nominal: 50-60 3-phase) Hz 47-66
Power Factor (typ) 0.95
Efficiency (200VAC)(typ) %87 88 90
Current (200-240VAC)(typ) A 4 5
Inrush Current (200-240VAC) (max) (*3)
A 35
Leakage Current 240VAC(UL,IEC) (max) (*10)
mA 1.3
Output
Nominal Voltage VDC 24 36 48
Maximum Current (*1) A 50 42 32
Maximum Power W 1200 1512 1536
Maximum Line Regulation
(Within input voltage range)(max/typ)
0.2%/0.1%
Maximum Load Regulation
(0-100% load)(max/typ)
0.4%/0.2%
Temperature Coefficient
(Ambient temperature -10℃to +65℃)(max/typ)
%1.0/0.5
Warm Up Drift (max/typ) (*4) %0.5/0.2
Maximum Ripple Voltage (max) (*2)
mVp-p
200 300
Maximum Ripple & Noise (max) (*2)
mVp-p
300 400
Start Up Time (200VAC)(typ) ms 400
Hold-up Time (200VAC)(typ) ms 20 24 16
Voltage Adjustable Range VDC 16.8-31.2 25.2-55.0 33.6-55.0
Function
Over Current Protection (*6) A 52.5-57.5 44.1-48.3 33.6-36.8
Over Voltage Protection (*5) VDC 32-36.4 56-60
Over Temperature Protection (*5)
Available
Remote Sensing (*9) Available
Remote ON/OFF Control (*8) Available
Parallel Operation
Applicable (current balance function and master/slave operation are supported; synchronized operation is not supported)
Series Operation Applicable
Operation Indicator Available (green LED)
Variable Output Voltage (*7) Available
Monitoring Signal Available (power fail signal)
Open Phase Dectation
Available (Output is shut down and fans are stopped when 1 of 3 phases is lost.) Resumes by restarting input
or resetting RC after the causes are removed. Interval before restarting input should be 30s or over.
Low Output Voltage Dectation
Not available
Fan Stop Protection
Output is shut down if fans are stopped for approximately 20s. Resumes by restarting input or resetting RC.
Environment
Operating Temperature ℃-10 to +65
Storage Temperature ℃-30 to +75
Operating Humidity
%RH
10-95 (the conditions of maximum 35°C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
%RH
10-95 (the conditions of maximum 35°C in wet bulb temperature and non-condensation should be ensured.)
Vibration
5-10Hz, 10 minutes sweep, 10mmp-p total amplitude, 3 directions, 1h for each, in non-operation
10-200Hz, 10 minutes sweep, 19.6m/s² (2G) acceleration, 3 directions, 1h for each, in non-operation
Shock 294m/s² (30G), 11 ±5ms, 3 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
For 1 minute at ordinary temperature and humidity
Between input terminal and ground terminal: 2.0kVAC, 10mA cutout current
Between input terminal and output terminal: 3.0kVAC, 10mA cutout current
Between output terminal and ground (G): 500VAC, 20mA cutout current
Isolation Resistance
In 500VDC and 100MΩor over at ordinary temperature and humidity
Between input terminal and ground terminal, between input terminal and output terminal,
and between output terminal and ground terminal
Standards
Safety Standards Approved by UL60950-1, CSA C22.2 No.60950-1 (C-UL)
EMI Complying with FCC-Class A / VCCI-Class A / EN55011-A / EN55022-A
Immunity Complying with EN61000-4-2/3/4/5/6/8/11, EN61000-6-2
Mechanical
Weight max g 3,000
Size (W x H x D) mm 120 x 92 x 237
With nominal input/output voltage, maximum output current, and Ta=25°C, if not specied separately.
(*1) The maximum output current value is between -10°C and +50°C. For use in outside this temperature range, derating is
needed.
(*2) 2 times the value in 100MHz and at between -10°C and 0°C.
(*3) In primary surge current, and 30s or over in input interval.
(*4) 30min to 8h after the start of input voltage application.
(*5) Output voltage shutdown system and voltage resumes by restarting input or resetting RC.
(*6) Fixed current/voltage reduction system (current is shut down if over current condition continues for 30 seconds or over).
Resumes by restarting input or resetting RC.)
(*7) Short-circuit between REF and RV when not in use.
(*8) Short-circuit between +RC and -RC when not in use.
(*9) Short-circuit between +S/-S and +/-output terminals when not in use.
(*10) In operation: AC240V, 60Hz, complying with IEC60990-1. 1.9mA max. in phase lack
RKY1500W Specifications
●
Recommended EMC Filter
RTEN-5010
Please refer to "TDK-Lambda
EMC Filters" catalog.