TDK ACM-V Series User manual

May 2018
EMC Components
Automotive power line (for power train/safety)
ACM90V
Common mode filters
ACM90V
type
ACM-V series

(2/7)
20180508 / cmf_automotive_power_acm90v_en.fm
EMC Components
REMINDERS FOR USING THESE PRODUCTS
Before using these products, be sure to request the delivery specifications.
SAFETY REMINDERS
Please pay sufficient attention to the warnings for safe designing when using these products.
The storage period is less than 12 months. Be sure to follow the storage conditions (Temperature: 5 to 40°C, Humidity: 10 to 75% RH
or less).
If the storage period elapses, the soldering of the terminal electrodes may deteriorate.
Do not use or store in locations where there are conditions such as gas corrosion (salt, acid, alkali, etc.).
Before soldering, be sure to preheat components.
The preheating temperature should be set so that the temperature difference between the solder temperature and chip temperature
does not exceed 150°C.
Soldering corrections after mounting should be within the range of the conditions determined in the specifications.
If overheated, a short circuit, performance deterioration, or lifespan shortening may occur.
When embedding a printed circuit board where a chip is mounted to a set, be sure that residual stress is not given to the chip due to
the overall distortion of the printed circuit board and partial distortion such as at screw tightening portions.
Self heating (temperature increase) occurs when the power is turned ON, so the tolerance should be sufficient for the set thermal
design.
Carefully lay out the coil for the circuit board design of the non-magnetic shield type.
A malfunction may occur due to magnetic interference.
Use a wrist band to discharge static electricity in your body through the grounding wire.
Do not expose the products to magnets or magnetic fields.
Do not use for a purpose outside of the contents regulated in the delivery specifications.
The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications
equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement
equipment, industrial robots) under a normal operation and use condition.
The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or
quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to
society, person or property.
If you intend to use the products in the applications listed below or if you have special requirements exceeding the range or conditions
set forth in the each catalog, please contact us.
(1) Aerospace/Aviation equipment
(2) Transportation equipment (electric trains, ships, etc.)
(3) Medical equipment
(4) Power-generation control equipment
(5) Atomic energy-related equipment
(6) Seabed equipment
(7) Transportation control equipment
(8) Public information-processing equipment
(9) Military equipment
(10) Electric heating apparatus, burning equipment
(11) Disaster prevention/crime prevention equipment
(12) Safety equipment
(13) Other applications that are not considered general-purpose
applications
When designing your equipment even for general-purpose applications, you are kindly requested to take into consideration securing
protection circuit/device or providing backup circuits in your equipment.
REMINDERS

(3/7)
20180508 / cmf_automotive_power_acm90v_en.fm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
EMC Components
Common mode filters
Automotive power line (for power train/safety)
FEATURES
Exclusive square type closed magnetic core designed as an exclusive core is used, so it can be small while maintaining the same
features.
Low profile design makes it optimal for surface mounting.
Excellent impedance characteristics, making it great for suppressing common mode noise.
The product series is designed for use up to 8A in an environment of 125°C.
Covers a wide operating temperature range from –40 to +125°C.
APPLICATION
Measures against common mode noise in power lines for various DC power lines, multimedia devices, and various electronic devices,
including automotive power trains and safety applications.
PART NUMBER CONSTRUCTION
OPERATING TEMPERATURE RANGE, PACKAGE QUANTITY, PRODUCT WEIGHT
The operating temperature range of this product does not include self-heating. The product can be used up to 150°C including self-heating.
When using the product in an environment at 125°C, use the product within the current range shown in the table on page 6/7 of this catalog.
The Storage temperature range is for after the circuit board is mounted.
Overview of ACM90V type
ACM 90V - 701 - 2PL - TL 00
Series name L×W×H Dimensions Impedance Number of lines Packaging style Internal code
(mm) () at 100MHz
90V 9.0×7.0×4.5 701 700 2PL 2 lines TL ø330mm reel 00
Type
Temperature range Reel diameter Package quantity Individual weight
Operating
temperature
(°C)
Storage
temperature
(°C) (mm)(pieces/reel) (g)
ACM90V –40 to +125 –40 to +125 ø330 800 0.82
Product compatible with RoHS directive
Compatible with lead-free solders
AEC-Q200
RoHS Directive Compliant Product: See the following for more details.https://product.tdk.com/info/en/environment/rohs/index.html

(4/7)
20180508 / cmf_automotive_power_acm90v_en.fm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
EMC Components
ACM90V type
RECOMMENDED REFLOW PROFILE
Preheating Soldering Peak
Temp. Time Temp. Time Temp. Time
T1 T2 t1 T3 t2 T4 t3
150°C 180°C 60 to 120s 230°C 10 to 30s 245°C 5s
Natural
cooling
t3
t1
Preheating
t2
Soldering
T3 T3
T4
T2
T1
t: Time
Peak
T: Temperature

(5/7)
20180508 / cmf_automotive_power_acm90v_en.fm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
EMC Components
ACM90V type
SHAPE & DIMENSIONS
RECOMMENDED LAND PATTERN CIRCUIT DIAGRAM
9.0±0.2
7.0±0.24.5max.
1
2
4
3
6.0typ.1.5±0.2 1.5±0.2
1.5±0.2 1.5±0.2
2.0±0.2
Dimensions in mm
3.5
6.0
11.0
1.5
Dimensions in mm
1
2
4
3
• No polarity

(6/7)
20180508 / cmf_automotive_power_acm90v_en.fm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
EMC Components
ACM90V type
ELECTRICAL CHARACTERISTICS
CHARACTERISTICS SPECIFICATION TABLE
○Measurement equipment
*Equivalent measurement equipment may be used.
IMPEDANCE VS. FREQUENCY CHARACTERISTICS
○Measurement equipment
*Equivalent measurement equipment may be used.
Common mode impedance
[at 100MHz]
DC resistance Rated current Rated voltage Insulation
resistance
Part No.
()min. ()typ. (m)max. (A)max. (V)max. (M)min.
500 700 10 5.0 80 10 ACM90V-701-2PL-TL00
Measurement item Product No. Manufacturer
Common mode impedance 4991A Keysight Technologies
DC resistance 4338A Keysight Technologies
Insulation resistance 4339A Keysight Technologies
Product No. Manufacturer
4991A Keysight Technologies
1 10 100 1000
10000
1000
1
10
100
Frequency (MHz)
Impedance (Ω)
701 Common mode
701 Differential mode

(7/7)
20180508 / cmf_automotive_power_acm90v_en.fm
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
EMC Components
ACM90V type
PACKAGING STYLE
REEL DIMENSIONS
TAPE DIMENSIONS
Ty p e A W1 W2 N E
ACM90V ø330±2 16.4+2/–0 20.4 typ. 100±1 2 typ.
Dimensions in mm
Ty p e A B øD0 E F P0 P1 P2 W K t
ACM90V 8.6±0.1 9.6±0.1 1.5+0.1/0 1.75±0.1 7.5±0.1 4.0±0.1 12.0±0.1 2.0±0.1 16.0±0.3 4.6±0.1 0.4±0.05
Ty p e L
ACM90V 440min.
ø13.0±0.2
ø21.0±0.8
N
E2.0±0.5
A
Dimensions in mm
1.0
W2
W1
B
FE
W
P0P2
P1
A
øD0 t
K
Dimensions in mm
160min. Taping L
Drawing direction
500 to 560min.
This manual suits for next models
1
Table of contents
Other TDK Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Koganei
Koganei iB-Cyclone iBSeries Handling Instructions and Precautions

Schaffner
Schaffner FN 3025 Installation guidelines

Brita
Brita MAXTRA PRO Instructions for use

Club Hydrate
Club Hydrate Perfect Pitcher owner's manual

Lancaster
Lancaster 7-LXDAN-1 Installation, operating and service manual

uv guard
uv guard SLT Series Installation and operation manual