technetix EDFA-R Operational manual

EDFA-R
Erbium Doped Fibre Amplifier
With Redundant Power Supplies
Online
Email: customer.service.[email protected]
Website: technetix.com
Apr/2018 - EU - V2
Technetix Group Limited
Product user manual

EDFA-R
Erbium Doped Fibre Amplifier
with Redundant Power Supplies
Product User Manual
Jan/2018 - EU - V1
Technetix Group Limited
User manual
EDFA-R

Contents
Safety precautions............................................................................................................................................................1
1 The description of the high power EDFA-R..........................................................................................................2
1.1 Overview ...................................................................................................................................................................................................2
1.2 Features.....................................................................................................................................................................................................2
1.3 Models and options ...............................................................................................................................................................................3
1.4 Mechanical figures .................................................................................................................................................................................5
2 Operating principle ...................................................................................................................................................6
2.1 The architecture of the equipment ...................................................................................................................................................6
3 Specifications.............................................................................................................................................................7
3.1 Parameters................................................................................................................................................................................................7
3.2 Management interface hardware feature.......................................................................................................................................9
3.2.1 RS232 interface..........................................................................................................................................................................9
3.2.2 RJ45 Ethernet interface hardware feature.........................................................................................................................9
3.3 SNMP agent network management system ..................................................................................................................................10
3.3.1 Standard compliant....................................................................................................................................................................10
3.3.2 Main features...............................................................................................................................................................................10
3.3.3 MIB File..........................................................................................................................................................................................10
3.4 RS 232 monitoring and terminal management (with RS232 communications) ..................................................................10
3.4.1 Hardware condition...................................................................................................................................................................10
3.4.2 Terminal management ..............................................................................................................................................................13
3.5 TELNET management and SNMP network management.........................................................................................................14
3.5.1 Hardware requirements...........................................................................................................................................................14
3.5.2 Network configurations............................................................................................................................................................15
3.5.3 TELNET operation......................................................................................................................................................................16
3.6 Laser safety ..............................................................................................................................................................................................17
3.6.1 Laser safety precautions..........................................................................................................................................................17
Jan/2018 - EU - V1
Technetix Group Limited
User manual
EDFA-R

3.7 Packaging, transport and storage.....................................................................................................................................................18
3.7.1 Package manifest.......................................................................................................................................................................18
3.7.2 Transportation .............................................................................................................................................................................18
3.7.3 Storage ..........................................................................................................................................................................................18
4 Equipment operation................................................................................................................................................19
4.1 Panel keys.................................................................................................................................................................................................19
4.2 Panel LEDs description.........................................................................................................................................................................19
4.3 Status display menu and instruction.................................................................................................................................................19
4.3.1 EDFA-R Front display main menu .........................................................................................................................................20
4.3.2 Device state Setting..................................................................................................................................................................21
4.3.3 Modify the working mode of the equipment.....................................................................................................................22
4.3.4 Change the pump laser state.................................................................................................................................................22
4.3.5 Modify the equipment alarm status......................................................................................................................................23
4.3.6 Change the output power.......................................................................................................................................................23
4.3.7 Select the COM port .................................................................................................................................................................23
4.3.8 Resetting the device .................................................................................................................................................................24
4.3.9 View the device serial number..............................................................................................................................................24
4.3.10 Network parameter configuration operation ...................................................................................................................24
4.3.11 LCD display translation table..................................................................................................................................................25
4.4 The definition of the alarm threshold...............................................................................................................................................25
Jan/2018 - EU - V1
Technetix Group Limited
User manual
EDFA-R

1Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
Safety precautions
Please read the manual first before installing and using this product. The manufacturer is not responsible for any
equipment damage, personal injury, or property damage caused by improper operation.
The laser output is a high-power invisible laser. The laser radiation can seriously damage
your eyes or skin.
Avoid vibration and collision. The device contains precision optical components
that can be damaged.
Please handle carefully and ensure the device is properly grounded.
The device is sensitive to static electricity.
Do not open the device. If there are any issues contact a Technetix
representative immediately.
Special notice for the optical fibre interface:
1. The optical fibre interface must be clean.
2. When setting up the device insert the output fibre first, then insert the input fibre.
When removing optical cables, remove the input first and then the output cable.

2Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
1 Description of the high power EDFA-R
1.1 Overview
The EDFA-R occupies 1RU or 2RU in a 19" sub-rack. The key component of this product is a very reliable multimode
pump laser. A unique Automatic Power Control (APC) and Automatic Temperature Control (ATC) circuit ensures stable and
reliable output power. The unique optical circuit design ensures excellent optical performance.
The optical circuit is designed specifically for CATV systems. It features a low noise profile to ensure an excellent CNR
for analogue systems sensitive to noise. The device also has a high level of spectral flatness across the entire C-band to
ensure better CSO. The design includes dual hot-swappable redundant power supplies to reduce the MTBF.
The EDFA-R has an intelligent temperature control system that can reduce power consumption by up to 30%. When the
case temperature is over 45 degrees Celsius, a fan will start and continue to operate until the temperature is under 40
degrees Celsius. The technology ensures the thermal stability of the system and increase the fan’s lifespan.
It has an intelligent network management system. The device can be controlled through the Ethernet interface, the RS-485
interface, and RS-232 interface. In addition, it can be controlled through SNMP MIB to integrate it with a variety of network
management systems.
1.2 Features
■ Low noise profile: typically less than 4.5 dB (0 dBm input)
■ Extremely low CSO distortion: <-70 dBc
■ Dual power supplies supporting 220V mixed interpolation with 48V
■ High stability and reliability: MTBF 100,000 hours
■ Multiple management interfaces: Ethernet, RS-485, and RS-232
■ Supports Telnet and standard SNMP network management
■ High precision AGC/APC circuit: precision is ± 0.05 dB
■ Intelligent temperature control system: power consumption reduced by up to 30% compared to similar products
■ 1RU or 2RU in a 19” sub-rack
■ Bellcore GR-1312-CORE compatible

3Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
1.3 Models and options
Model code:
EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
Erbium Doped Fibre Amplifier (Optical Amplifier) with Redundant Power Supplies
EDFA-R-I-[U-V]-[W]-[X]-[Y]-[Z]
Erbium Doped Fibre Amplifier (Optical Amplifier) with redundant power supplies and input power threshold range of -10~10 dBm
Options:
1RU Height Number of Output Ports and Output Power
1-13 1 * 13 dBm (13 dBm/per port, 1 port. total 20 mw, 13 dBm), 1RU
1-24 1 * 24 dBm (24 dBm/per port, 1 port. total 250 mw, 24 dBm), 1RU
2-13 2 * 13 dBm (13 dBm/per port, 2 ports. total 40 mw, 16 dBm), 1RU
2-21 2 * 21 dBm (21 dBm/per port, 2 ports. total 250 mw, 24 dBm), 1RU
4-13 4 * 13 dBm (13 dBm/per port, 4 ports. total 80 mw, 19 dBm), 1RU
4-18 4 * 18 dBm (18 dBm/per port, 4 ports. total 250 mw, 24 dBm), 1RU
4-22 4 * 22 dBm (22 dBm/per port, 4 ports. total 634 mw, 28 dBm), 1RU
5-16 5 * 16 dBm (16 dBm/per port, 5 ports. total 200 mw, 23 dBm), 1RU
6-16 6 * 16 dBm (16 dBm/per port, 6 ports. total 240 mw, 24 dBm), 1RU
2RU Height(1) Number of Output Ports and Output Power
8-15 8 * 15 dBm (15 dBm/per port, 8 ports. total 256 mw, 24 dBm), 2RU
8-16 8 * 16 dBm (16 dBm/per port, 8 ports. total 320 mw, 25 dBm), 2RU
8-22 8 * 22 dBm (22 dBm/per port, 8 ports. total 1268 mw, 31 dBm), 2RU
10-22 10 * 22 dBm (22 dBm/per port, 10 ports. total 1585 mw, 32 dBm), 2RU
12-16 12 * 16 dBm (16 dBm/per port, 12 ports. total 480 mw, 27 dBm), 2RU
16-16 16 * 16 dBm (16 dBm/per port, 16 ports. total 640 mw, 28 dBm), 2RU
16-17 16 * 17 dBm (17 dBm/per port, 16 ports. total 802 mw, 29 dBm), 2RU
16-20 16 * 20 dBm (20 dBm/per port, 16 ports. total 1585 mw, 32 dBm), 2RU
20-20 20 * 20 dBm (20 dBm/per port, 20 ports. total 2000 mw, 33 dBm), 2RU
24-8 24 * 8 dBm (8 dBm/per port, 24 ports. total 151 mw, 22 dBm), 2RU
24-16 24 * 16 dBm (16 dBm/per port, 24 ports. total 960 mw, 30 dBm), 2RU
24-18 24 * 18 dBm (18 dBm/per port, 24 ports. total 1585 mw, 32 dBm), 2RU
32-17 32 * 17 dBm (17 dBm/per port, 32 ports. total 1585 mw, 32 dBm), 2RU
EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
(1)The 2RU device is used for the types with more than 6 output ports.

4Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
Optical Connector
SSC/APC optical connector
EE2000/APC optical connector
FFC/APC fit optical connector
LLC/APC optical connector
Power Supply Options (AC = 90~265 Vac, 50~ 60 Hz; DC = 36~72 Vdc)
1A SC/APC optical connector
2A E2000/APC optical connector
1D FC/APC fit optical connector
2D LC/APC optical connector
AD FC/APC fit optical connector
Power Cable
EU Power cable for Europe (not for use in UK)
CN Power cable for China
CH Power cable for Switzerland
US Power cable for USA
UK Power cable for UK
AU Power cable for Australia
Power Cable
EDFA-RPSAC Mains power supply 220 Vac (AC = 90~265 Vac, 50~60 Hz)
EDFA-RPSDC Mains power supply -48 Vdc (DC = 36~72 Vdc)
Network Management
0None
1SNMP
EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
Accessories

5Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
1.4 Mechanical figures
Case Size: 483 × 380 × 44 mm (max)
Net weight: 6.1 kg

6Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
2 Operating principle
2.1 The architecture of the equipment
Output Signal
Multimode Pump
Multimode Pump
IsolatorIsolator Combiner
Er Yb
Double Cladding Fibre
TAP TAPInput Signal
Input PD Output PD
Amplifier Unit

7Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3 Specifications
3.1 Parameters
Optical performance
Parameters Symbol Min Typ Max Unit Notes
Optical wavelength λc 1530 1550 1565 Nm
Saturated output power Posat 13 - 32 dBm 1
Input power Pi -3 - +10 dBm 2
Gain G - 20 - dB
Noise level NF - 4.5 - dB 3
Output power stability ΔPo - ±0.05 ±0.1 dB
Input isolation ISOi 30 - - dB
Output isolation ISOo 30 - - dB
Input pump leakage PLi - - -35 dBm
Output pump leakage PLo - - -45 dBm
Return loss RL - - -45 dB
Polarization dependent gain PDG - -0.3 dB
PMD PMD - - 0.5 ps
Optical connector SC/APC, E2000/APC, FC/APC, LC/APC
Parameters Symbol Min Typ Max Unit Notes
Power supply Vps 85/170 220 132/264 VAC 4
Power consumption P - - 18 W 5
Parameters Symbol Min Typ Max Unit Notes
Operation temperature Tw -5 - 60 °C
Storage temperature Ts -40 - 0 °C
Humidity (no condensation) Pi 10 - 90 %
Dimensions (H × W × D) 44 × 483 × 220 mm
Weight 6.0 kg
Electrical performance
General
Notes
1 Customer optional
2 Standard input power range, only for EDFA-R-[U-V]-[W]-[X]-[Y]-[Z]
3 Test at 0 dBm input power
4 220 Vac, -48 Vdc and 220 Vac / -48 Vdc are optional
5The actual power consumption is relative to output power
and operation environment temperature

8Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
PIN 1
+
DC
DC: -35~-72 V
−
PIN 3 PIN 2
-48 VDC Interface
PGND: power ground
CGND: chassis ground
-48 V: power -48 V
PIN 1 = Red
PIN 1 = Red
PIN 2 = Yellow
PIN 2 = Yellow Green
PIN 3 = Green
PIN 3 = Blue
PGND
CGND
-48 V
-48 VDC interface definition:
220 VAC interface definition:
E
NL
220 VAC interface
L: live
N: neutral
E: earth
L
E
N

9Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3.2 Management interface hardware feature
3.2.1 RS232 interface
General features
Interface type: DB-9 (female)
Baud rate: 9600 bit/s
Data Bit: 8
Parity: O
Stop bit: 1
Data flow control: O
RS232 interface specification
RS232 Interface rule for example Table 3.1
3.2.2 RJ45 Ethernet interface hardware feature
RJ45 Ethernet interface specifications
Transmission Line
PIN 2 (RXD)
PIN 3 (TXD)
PIN 5 (GND)
RXD, TXD Logic1 (MARK) Voltage Amplitude -3~15 V
RXD, TXD Logic0 (SPACE) Voltage Amplitude 3~15 V
The Max. Transmission Distance 15 m
Driver Load Capacitance <2500 pf
Interface type RJ45
Speed rate 10 Mbit/s
Table 3.1: RS232 interface feature
Table 3.1: RS232 interface feature
RS232 interface specification
RS232 interface is fully compliant with standard RS232 interface specifications to ensure distortion is less than 4%.

10 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3.3 SNMP AGENT network management system
The SNMPv1 and SNMPv2 are supported by the firmware. It can be accessed by the standard SNMP network
management tools.
Through network management software, detailed parameters can be viewed including performance parameters, power
information, device temperatures, and history record.
3.3.1 Standard compliant
1. Compliant with SNMP version 1
2. Compliant with SNMP version 2
3.3.2 Main features
1. Fault monitoring: notifications when there is an error or abnormality in the network
2. Configuration management: configuration parameters can be set through the configuration interface
3. Performance management: the device can automatically collect statistical data for the to assess system performance
3.3.3 MIB file
Standard MIB tree (Figure: 3-1).
Please contact Technetix' technical support for the full list of MIB parameters
3.4 RS 232 monitoring and terminal management (with RS232 communications)
The equipment can be accessed from a PC by a female to female DB-9 connection and the communication distance
must not exceed 12 m.
3.4.1 Hardware condition
Transmission line Parameter Quantity
RS232 cross line DB-9 (female) 1
PC Serial port software, with DB-9 male COM port,
Windows system 1
Amplifier 2U amplifier with serial port communication 1

11 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
Figure 3-1 standard MIB tree

12 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
DB-9 cross line connectivity
Crosses line connectivity figure:
DB-9 female 1 DB-9 female 2 Connectivity
PIN2 PIN3 Interconnected
PIN3 PIN2 Interconnected
PIN5 PIN5 Interconnected
PIN1, PIN4, PIN6 PIN7, PIN8, PIN9 PIN1, PIN4, PIN6 PIN7, PIN8, PIN9 Interconnected or disconnect
PIN 9
PIN 5
PIN 6 PIN 1
DB-9 female 1 DB-9 female 2
Figure 3-2 DB-9 cross connection layout

13 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3.4.2 Terminal management
Connect the equipment and PC by a serial cable and power on the equipment, and then start the terminal software
according to the parameters of the selected serial port (9600 bps, 8 bit data, 1 bit stop, parity and flow control o).
Once a terminal connection is successfully established, please input the user name 'admin' and the password '12345'.
After successfully logging in, type '?' or 'help', then press the [Enter] key to retrieve a list of supported commands.
Command Syntax Command explanation Additional information
Exit N/A Exit serial console mode
This command exits serial console mode.
The [Enter] key must be pressed 3 times
before another entering command.
Enter N/A In application mode, pressing [Enter] key
3 times to use console mode -
Admin N/A The username is ADMIN when logging in. The unit only supports one user account
Password N/A When the terminal displays a "*", the user
is bring prompted for a password The default admin password is '12345'
Logout N/A Logs the current user out -
Help N/A Displays the help interface -
?N/A Displays the help interface -
ver N/A Displays the equipment version -
Set IP
[IP Address] Used to set an IP address -
Show N/A Displays the equipment
configuration information -
Set Logo xxxxxx Set a string of text to act as a logo
The content of logo text must be less
than 20 characters and quotation marks
must be used
Serial port console commands

14 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3.5 TELNET management and SNMP network management
3.5.1 Hardware requirements
T568A
T568B
T568B
T568B
Item Parameter Quantity
Network line Crossover cable, straight-through cable 1
PC Network management software and a Telnet client
should be installed. 1
Amplifier 2U Amplifier, with Ethernet port 1
Network LAN, Internet 1
The corresponding Figure 3-3 of network cable:
PIN 1 PIN 1
568A Male 568B Male
568A Male:
Orange and White—1, Orange—2, Green and White—3, Blue—4,
Blue and White—5, Green—6, Brown and White—7, Brown—8,
568B Male:
Green and White—1, Green—2, Orange and White—3, Blue—4,
Blue and White—5, Orange—6, Brown and White—7, Brown—8,
Cross lines:
Two heads the center line of a dierent order, namely: one for the T568A, one for the T568B;
Direct line:
Two heads the center line of the same order, such as the two are T568B stander;
Figure 3-3 Network line connection figure

15 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3.5.2 Network configuration
The steps for directly connecting the equipment with a PC:
1. Set the IP address through the front panel
2. Connect the RJ-45 port to a PC Ethernet port using a crossover Ethernet cable
The steps for connecting equipment with a PC through a network:
1. Set the IP address by front panel
2. Connect the RJ-45 port on equipment to a switch, router, or hub that also connects to a PC
The steps for connecting equipment with PC through network:
Figure 3-4 Network Connect
Internet
Network
management
Router
Router
EDFA1
EDFA4
EDFA5
EDFA6
EDFA2 EDFA3

16 Apr/2018 - EU - V2
Technetix Group Limited
User manual
EDFA-R
3.5.3 TELNET operation
1. The EDFA-R supports TELNET management.
To access the EDFA-R's TELNET server from Windows, open a DOS command prompt and type 'Telnet 192.168.25.168'.
Press the [Enter] key and the computer should connect with the equipment. In this example, '192.168.25.168' is the IP
address of the equipment.
2. After successfully connecting, the user name and password is required
Table of contents
Other technetix Amplifier manuals

technetix
technetix DBC-1200 User manual

technetix
technetix DBE-1200S User manual

technetix
technetix AIMA-FPAS Operational manual

technetix
technetix AIMA3000.RPAS Operational manual

technetix
technetix AIMA3000.FPAE Operational manual

technetix
technetix DBC-1200 User manual

technetix
technetix DBC-1200 User manual

technetix
technetix LINDSAY BROADBAND LMDA3726 Series User manual

technetix
technetix DBD-1200 User manual

technetix
technetix DBC-1200S User manual