TechnipFMC Smith Meter User manual

Contents
Section 1 – General Information ................................................................................................................. Page 2
Return Procedures ......................................................................................................................................... Page 2
Section 2 – Service....................................................................................................................................... Page 3
Section 3 – Troubleshooting Guide ............................................................................................................ Page 9
Section 4 – Maintenance and Calibration Record ................................................................................... Page 10
Section 5 – Related Publications ...............................................................................................................Page 11
MANUAL
Smith Meter®Turbine Meters
Service Manual

Issue/Rev. 0.3 (8/02)
-
be lengthened or shortened.
sure the trouble is in the meter.
Bulletin SS02001
Return Procedures
-
-
-

Issue/Rev. 0.3 (8/02)
Section 2 – Service
Removal and Replacement of Pick-Up
Coil With Meter in Product Line
meter.
Figure 1
Figure 2
Caution: Tighten pick-up coil nger tight. Over tightening
will result in damage to coil.
Removal and Replacement of Preamplier
With Meter in Product Line
through 5.
Figure 3
Figure 4
Figure 5

Issue/Rev. 0.3 (8/02)
Figure 6
Removal and Servicing of Meter lnternals
meter.
re-moving bolts and nuts.
Figure 7
Figure 8
Figure 9
Figure 10

Issue/Rev. 0.3 (8/02)
stator.
Figure 11
motion.
Figure 12

Issue/Rev. 0.3 (8/02)
Note: It will be necessary to remove one deector ring
when servicing a bidirectional turbine meter.
Figure 13
Figure 14
Reassembly of lnternals
Table 1
Meter Sizes Thread Size Torque Required
(Lubricated) ±5%
22 in-lb
Rotor is marked “IN” on upstream
side of rotor.
against stator.
Figure 15

Issue/Rev. 0.3 (8/02)
Figure 16
bidirectional turbine meter.
Figure 17
Figure 18
Additional Notes
Upstream
Stator
Downstream
Stator
45˚ (Approx.)
Figure 19
Note: When a meter is disassembled and reassembled,
it should be recalibrated for optimum accuracy.

Issue/Rev. 0.3 (8/02)
Test
during installation. Proving the meter should be under
-

Issue/Rev. 0.3 (8/02)
Section 3 – Troubleshooting Guide
Problem Probable Cause Corrective Action
Clean.
Bent blades.
Missing rotor blade.
Clean.
Remove and clean.
Bent blades.
Cavitation.
Noise on transmission line.
Damaged or missing blade.
Clean.
Noise.
Bulletin SS02012

Issue/Rev. 0.3 (8/02)
Issue/Rev. 0.3 (8/02) MN02004 • 9
Meter No.
Serial No.
Product
Flow Rate
"K" Factor
Date ProvedBy
Remarks
Meter No.
Serial No.
Product
Flow Rate
"K" Factor
Date ProvedBy
Remarks
Meter No.
Serial No.
Product
Flow Rate
"K" Factor
Date ProvedBy
Remarks
Meter No.
Serial No.
Product
Flow Rate
"K" Factor
Date ProvedBy
Remarks
Maintenance and Calibration Record

Issue/Rev. 0.3 (8/02)
Section 5 – Related Publications
-
.
Turbine Meters
Manual
......................................................................................... MN02003
Specications
............................................................................................................................. SS02001
.................................................................................................................... SS0200
......................................................................................................................................... SS02012
Parts Lists
...........................................................................................................................................13
.....................................................................................................
...........................................................................................................................................15
..........................................................................................................16
....................................................................................................................
...................................................................................................................
....................................................................................................................19
.........................................................................................................................................20
.........................................................................................................................................21

TechnipFMC.com
Regentstrasse 1
-
Field Service Response Center
Technical Support
Other manuals for Smith Meter
1
Table of contents
Other TechnipFMC Measuring Instrument manuals

TechnipFMC
TechnipFMC Smith Meter Genesis Series User manual

TechnipFMC
TechnipFMC Smith Meter Instruction manual

TechnipFMC
TechnipFMC Smith Meter AccuLoad IV Instruction Manual

TechnipFMC
TechnipFMC Sening MultiLevel User manual

TechnipFMC
TechnipFMC Proline Promass E 500 Instruction Manual

TechnipFMC
TechnipFMC Smith Meter PRIME 4 User manual

TechnipFMC
TechnipFMC Smith Meter MMRT User manual

TechnipFMC
TechnipFMC Smith Meter MPU C Series Instruction manual

TechnipFMC
TechnipFMC Smith Meter AccuLoad IV Series Manual

TechnipFMC
TechnipFMC Smith Meter AccuLoad III User manual