TECLOCK SSD Series User manual

User’s Manual
Bluetooth Digital Depth Gauge
Type : SSD Series
1
Q-152-1-E Ver1.4
Display
Base
Probe
Button
Button
Button
Battery cover
Battery cover
Display
Base
Probe
Button
Button
Button
Parts Features
Battery cover for exchange the Battery(CR2032)
Display Display Measuring value, Setting mode, etc.
Button Basic function by short press, Advanced function by long press
Button Change each mode, digit, etc.
Button Send button on Measuring, Enter button on setting
Base Measuring Base
Probe Contact point
*1) Refer to Indicator manual for detail operation.
*2) Refer to Chapter 6 about Probe shape.

Discription
2
16
17
5
43
(94.7) (12.3)
a
25.4
16
7.5
a
(107.9) (20.1)
Φ59.5
Type
Base Shape
a x 16
Hole diameter
in Base bottom plane
SSD-210 75x16 2.5
SSD-211 75x16 2.5
SSD-213 75x16 5.2
SSD-214 75x16 5.2
SSD-215 100x16 5.2
SSD-2100M 75x16 2.5
SSD-2110M 75x16 2.5
SSD-2130M 75x16 5.2
Unit:mm
Type
Base Shape
a x 16
Hole diameter
in Base bottom plane
SSD-2100 75x16 2.5
SSD-2150 100x16 5.2
Unit:mm

3
SSD-293
SSD-250
SSD-2500M
SSD-251
SSD-252
SSD-2520M
SSD-280
SSD-283
SSD-2400
SSD-2410
Detail

1.Power on/off operation
(1)Power on Press any button, then Power on.
(2)Power off
①Long press button(2 sec. or more), then it is standby and display is disappeared.
②Long press button(4 sec. or more), then 「off」displayed and Power off.
※)In the case of no using for a long time, do ②operation.
2.Preparation for Measuring
(1)Setting positive value in a measuring value
①Long press button, then Advanced mode.
②Short press button, 「dir」displayed.
※) button press times:1/100mmtype is one time, 1/1000mmtype are two times.
③Short press button 2 times, then negative displayed, and press button.
(2)Setting for Bluetooth
①Long press button, then Advanced mode.(「Unit」displayed)
②Short press button 5 times, then 「bt CFG」displayed.(Bluetooth setting mode)
③Short press button any times, then select 「HID」or 「PAIr」and press button.
④Short press button any times, then 「bt」displayed.(Bluetooth setting mode)
⑤Short press button, then select 「on」and press button.(Bluetooth on mode)
⑥Short press button any times, then 「bt」displayed.(Bluetooth setting mode)
⑦Short press button, then 「rESEt」displayed and press button.(Bluetooth Reset)
⑧Pair connection with PC.
⑨Display on Bluetooth mode
4
Display status Operating mode
off Bluetooth disconnected
blinkinng Bluetooth advertising
on Bluetooth connected
reset : clear pairing information
MAC : display the MAC address
Simple : profile without pairing
Pair : paired and secured profile
HID : virtual keyboard
Mini Indicator Standard Indicator
Pairモード SY303 SY289
HIDモード S Dial Mini HID S Dial work HID
Pairing mode
Instrument name on PC display

3.Measuring
(1)Setting zero point
①As shown in the Figure.1、bring the base surface into firm contact with the plane being the
reference surface of measurement.
②Short press button, then 「Zero」displayed and reset.(Figure.1)
*)Don’t slide this one right and left, back and forth, leaving the base contacting to the
reference surface.(Figure.2)
(2)Depth measuring
As shown in the Figure.3, bring the base surface into firm contact with the plane being the
reference surface of measurement and put the contact point at the measuring position of the
concave part where the depth is measured. Press button, then measuring data is sent to
PC.
4.Maintenance
Carefully dry all mechanical parts of the instrument after contact with liquids to ensure proper
operation and avoid corrosion.
Don’t use aggressive products (alcohol, trichloroethylene or others) to clean plastic parts.
Don’t expose the instrument to direct sunlight, heat or humidity
5.Installing and replacing the battery
(1)In case Mini Indicator (2)In case Standard Indicator
(SSI-150S、SSI-250)(SSI-550、SSI-560)
5
Reference
Press gently. Don’t slide Press gently
by hands.
Figure.1:ZeroReset
No spacing nor
lilting.
Zero Reset
Figure.2:Sliding prohibited Figure.3:Depth Measuring
Reference

6.Specifications
7.Certification
6
contains bluetooth module ISP091201D
Region Certification
USA FCC ID : 2AAQS-ISP091201
Canada IC : 11306A-ISP091201
Brazil Anatel : 0516-14-4534
Korea South MSIP-CRM-iNs-ISP091201
Mexico IFT : RCPSYIS14-0655
Japan 001-A06167
Taiwan CCAH18LP2040T6
EU
India WPC : ETA-1003/2-17-/RLO(WR)
Type SSD-210 SSD-211 SSD-213 SSD-214 SSD-215 SSD-2100M SSD-2110M SSD-2130M SSD-2100 SSD-2150
Resplution(mm)
Measuring range(mm)
Indication error(μm)
Contact point(mm) Needle Φ2Flat Φ3.2Steel ball Φ3.2Steel ball Φ3.2Steel ball Needle Φ2Flat Φ3.2Steel ball Needle Φ3.2Steel ball
Extension rod
Base shape(mm) 100x16 17x16 100x16
Base hole diameter(mm) Φ2.5 Φ2.5 Φ5.2 Φ5.2 Φ5.2 Φ2.5 Φ2.5 Φ5.2 Φ2.5 Φ5.2
Weight(g) 239 270 262 323
Built-in Indicator
Measuring force(N)
Working temperature(℃)
Strage temperature(℃)
IP protection
Battery life
Battery
IP67
IP54
about 6 months(under general using)
CR2032
SSI-550
0.5~0.9±20%
0.65~0.9±20%
5~40
-10~60
75x16
75x16
214
214
SSI-150S
SSI-250
±20
±6
±5
None
5pcs
None
5pcs
0.01
0.001
12
12
220(5pcs extension rods)
12
12
220(5pcs extension rods)
Type SSD-293 SSD-250 SSD-251 SSD-252 SSD-280 SSD-283 SSD-2500M SSD-2520M SSD-2400 SSD-2410
Resplution(mm) 0.01
Measuring range(mm)
12
220
(5pcs extension rods)
5 5
凹5凸4 12 12 5凹5凸4 25 25
Indication error(μm) ±20
Contact point(mm) Φ3.2Steel ball Needle Spesial needle Needle Needle Φ3.2Steel ball Needle Needle Needle Φ3.2Steel ball
Extension rod 5pcs
Base shape(mm) 150x80 50x16
Special
Φ16Cylinder
50x16
Φ16Cylinder Φ25Cylinder 50x16 50x16 100x16 100x16
Base hole diameter(mm) Φ11.0 Φ2.0 Special Special Φ3.0 Φ8.0 Φ2.5 Φ5.2 Φ2.0 Φ8.0
Weight(g) 450 160 130 160 140 150 149 144 327 307
Built-in Indicator SSI-150S
Measuring force(N)
Working temperature(℃)
Strage temperature(℃)
IP protection
Battery life
Battery
about 6 months(under general using)
CR2032
0.5~0.9±20%
0.65~1.15±20%
5~40
-10~60
IP67
IP54
None
None
None
SSI-150S
SSI-250
SSI-560
0.01
0.001
0.001
±20
±6
±6

CERTIFICATE OF CALIBRATION
We hereby certify that this product has been calibrated and found to be in accordance with the
applicable NATIONAL STANDARDS and TECLOCK STANDARDS, Equipment used in this calibration has
traceable accuracy to the NATIONAL LENGTH and FORCE STANDARD.
Notice for use
Be sure to conduct a routine check for this product according to the purpose of use before use. This
product is precision instrument, periodically considering frequency of use, environmental conditions and
method of use.
It is not guaranteed for the performance of this product, which has been repaired or disassembled by
other than TECLOCK.
For appearance and other design improvement, this products
subject to change without advance notice.
TECLOCK Corporation
TECLOCK SmartSolutions Corporation
http://www.teclock.co.jp
HEAD OFFICE
2-10-3 MARUTA-CHO, OKAYA-SHI, NAGANO-KEN 394-0042
PHONE:81-266-22-4912, FACSIMILE:81-266-22-4914
E-mail:[email protected]
This manual suits for next models
8
Table of contents
Other TECLOCK Measuring Instrument manuals