INSTALLER’S MANUAL
Page Nº: 43 of 95
5 DECORATIVE HOODS
When fitting a decorative hood, there are a number of important factors to bear in mind. These
include:
Before installing the hood, check that there are is no aesthetic damage, such as scratches
or dents before you procede.
Check that all the technical information appearing on the specification plate corresponds to
the characteristics of the mains electrical supply in question (voltage and frequency).
Respect at all times the local regulations referring to electrical installation and evacuation of
gases.
The appliance should be connected to the mains supply via a suitable omnipolar switch
with a 3 mm miminum gap between contacts.
Do not connect the appliance to ducts used for the evacuation of gases of a non-electrical
nature, such as boilers, chimneys etc.
Do not start up the appliance if the mains cable or control panel appear to be damaged in
any way.
Once the apparatus has been fitted, ensure that the mains cable does not come into
contact with sharp metal edges.
Minimum distances between the hob and hood should be strictly observed: 60cm for
electric hobs 70 cm for gas and mixed hobs.
For optimum performance, theexit duct should not exceed 4 metres in length, nor have
more than two 90ºbends, and its diameter should be at least 120 mm.
44
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 44 of 95
Model Dimensions
ISLA
ND ALADA ISLA
DS ISLA
45
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 45 of 95
Model Dimensions
CL 90
DX 90
ASYMETRIC DA 90
46
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 46 of 95
Model Dimensions
DS 60.1/70/90
DI 70/90/110
DM 60/70/90
47
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 47 of 95
Model Dimensions
DE 60.2 / 70.2/ 90.2
ND ALADA 70 / 90
CONICAL DC 60/70/90
48
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 48 of 95
Model Dimensions
RUSTIC DR 90
Model Dimensions
DF 90
49
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 49 of 95
DP DH DAL
Accessories supplied with decorative hoods:
150/125 mm adaptor
Anti-return valve
Support for tube cover
Support for wall mounting
Screws
Rawlplugs
Washers
50
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 50 of 95
5.1 INSTALLATION OF DECORATIVE HOOD
DX ISLA
This hood should be fitted in the following way:
1) Using the support (O), mark and make a small hole for the screws (S) (8x45) in the ceiling.
2) Secure the support with the corresponding screws (S).
3) Place the upper part of the internal structure (A6) on the support (O), with screws (Q)
(M6x16).
4) Adjust the decorative supplementary piece (U), carefully securing it with the screws (V) (M4)
supplied with the piece.
5) Insert piece (B) if the interior tube (not supplied) has a diametre of 120 mm.
6) Secure the interior tube with a jubilee clip (not supplied) to (B), or on the exit section of the
motor, as appropriate.
7) Insert the upper tube cover (A8) inside the lower tube cover (A9).
51
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 51 of 95
8) Adapt the combination of the lower tube cover (A9) and the upper tube cover (A8) to the
lower part of the of the internal structure (A7) and the decorative extra piece (U).
9) Fit the whole of the combined lower piece to the upper piece and mount on the ceiling with
the screws provided (A10) (M4 x 12), to the desired height.
10) Connect the upper part of the inner tube (not included) to the exit.
11) Lift the upper tube cover (A8) and secure it to the upper part with the supplied screws (G)
(M4 x 12), with a conical head.
12) Adjust the decorative supplementary piece (U), securing it to the hood with the screws (V)
(M4) supplied with the piece.
52
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 52 of 95
ND ALADA ISLA
DS ISLA
DX 90
53
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 53of 95
ASYMETRIC DA 90
DS 60.1/70/90
DI 70/90/110
54
Cód.: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 54 of 95
DM 60/70/90
ND ALADA 70 / 90
DE 60.2 / 70.2/ 90.2
55
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 55 of 95
CONICAL DC
RUSTIC DR 90
56
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 56 of 95
5.2 ACTIVE CARBON KIT FOR AIR RECIRCULATION
When the evacuation of gases to the exterior is not possible, our hoods can be adapted to purify
the air in the kitchen, making air circulation possible via active carbon filters.
There are two types of carbon filters:
5.2.1 SET Type 1
1) Place the filters in the lateral section of the extractor motor, making sure that the filter
openings (A) coincide with the pivots (B) of the motor housing. Turn in the direction as
shown in the diagram.
2) Remove the tube covers (E). Place the sheet (C) on the air outlet section of the motor.
3) Replace the tube covers (E).
5.2.2 SET Type 2
1) Attach the nut to the support (F) on the hood body.
2) Secure the supports (B) with the screws (E) to the nuts (F).
3) Fit the carbon filters (A) by inserting the attachment points into the support slots (B)
4) Remove the tube covers. Place the sheet (C) inside the lower tube cover with the screws
suppied (D). Replace the tube covers.
SET Type 1 SET Type 2
57
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 57 of 95
NEW RECIRCULATION KITS FROM JANUARY 2006.
58
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 58of 95
6 EXTRACTOR HOODS
During installation of extractor hoods there are a series of important factors to be taken into
consideration, as outlined below:
Check that all the technical information appearing on the specification plate corresponds to
the characteristics of the mains electrical supply in question (voltage and frequency).
Respect at all times the local regulations referring to electrical installation and evacuation of
gases.
The appliance should be connected to the mains supply via a suitable omnipolar switch
with a 3 mm miminum gap between contacts.
Do not connect the appliance to ducts used for the evacuation of gases of a non-electrical
nature, such as boilers, chimneys etc.
Do not start up the appliance if the mains cable or control panel appear to be damaged in
any way.
Once the apparatus has been fitted, ensure that the mains cable does not come into
contact with sharp metal edges.
Minimum distances between the hob and hood should be strictly observed: 60 cm for
electric hobs 70 cm for gas and mixed hobs. For E/70 hobs, this distance should be 76 cm.
For optimum performance, the outlet duct should not exceed 4 metres in length, nor have
more than two 90ºbends, and its diameter should be at least 120 mm.
59
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 59 of 95
Model Dimensions
C620
C 901
GF 2
60
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 60of 95
Model Dimensions
CNL 1001/2002
61
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 61 of 95
6.1 INSTALLATION OF EXTRACTOR HOOD
C-620
Installation diagrams for extractor hoods are as follows:
Fijaciónenlapared
Installation under a cabinet
(Opening for smoke exhauster)
When cutting out the upper part an evacuation duct outlet
must be included. In this case, the evacuation lever should
be in the “E”position.
In the event that there is recirculation instead of evacuation,
the lever should be in the “I”position. Ensure that the
upper opening is covered.
Wall installation
(Top edge of hood supported on wall)
(2 5 mm Ødrill holes)
62
Code Nº: PRM-00-0001
Revised / Date: 2006
INSTALLER’S MANUAL
Page Nº: 62 of 95
GF1 / GF2
Diagram for installation in a kichen cabinet
47mmØdrill holes (A) Exit for 2 motors (B) Exit for 1 motor
This hood can be attached in two ways:
1) With the screws supplied in the
accessories bag, the hood is attached to
the wood panel in which the recess
space has previously been cut.
2) Via the wood panel in the upper part of
the hood which has been previously cut
to size in order to allow the gas outlet
duct, mains cable and attachment
screws to be fitted. (See illustration for
installation in a kitchen cabinet).

This manual suits for next models

14

Other Teka Ventilation Hood manuals

Teka GHF-55 User manual

Teka

Teka GHF-55 User manual

Teka CNL 1001 User manual

Teka

Teka CNL 1001 User manual

Teka DVF 67670 TBL User manual

Teka

Teka DVF 67670 TBL User manual

Teka CNL1-3000 User manual

Teka

Teka CNL1-3000 User manual

Teka GFG2 User manual

Teka

Teka GFG2 User manual

Teka DVN 64030 TTC BK User manual

Teka

Teka DVN 64030 TTC BK User manual

Teka TLR62 User manual

Teka

Teka TLR62 User manual

Teka CMH1 User manual

Teka

Teka CMH1 User manual

Teka AEH-600 User manual

Teka

Teka AEH-600 User manual

Teka DV-80 S/S User manual

Teka

Teka DV-80 S/S User manual

Teka DF-90 User manual

Teka

Teka DF-90 User manual

Teka DBE-60 User manual

Teka

Teka DBE-60 User manual

Teka LMD 504 User manual

Teka

Teka LMD 504 User manual

Teka DR-90 User manual

Teka

Teka DR-90 User manual

Teka CC 40 User manual

Teka

Teka CC 40 User manual

Teka DVF 67670 User manual

Teka

Teka DVF 67670 User manual

Teka DVS 983 BK User manual

Teka

Teka DVS 983 BK User manual

Teka DA-90 User manual

Teka

Teka DA-90 User manual

Teka GFH-55 User manual

Teka

Teka GFH-55 User manual

Teka C-601 User manual

Teka

Teka C-601 User manual

Teka CS-6000 Instructions for use

Teka

Teka CS-6000 Instructions for use

Teka DY-70 User manual

Teka

Teka DY-70 User manual

Teka Pertecta4 DLH 985 User manual

Teka

Teka Pertecta4 DLH 985 User manual

Teka TBS 68660 User manual

Teka

Teka TBS 68660 User manual

Popular Ventilation Hood manuals by other brands

Becken BCHVS3123 instruction manual

Becken

Becken BCHVS3123 instruction manual

S&P EBB-170 NS manual

S&P

S&P EBB-170 NS manual

Klarstein PAOLO manual

Klarstein

Klarstein PAOLO manual

Zephyr Essentials Breeze I AK1124 Series Use, care and installation guide

Zephyr Essentials

Zephyr Essentials Breeze I AK1124 Series Use, care and installation guide

Bertazzoni KU24PRO1X/14 installation instructions

Bertazzoni

Bertazzoni KU24PRO1X/14 installation instructions

Fujioh BUF-01A Operation manual

Fujioh

Fujioh BUF-01A Operation manual

Fisher & Paykel HP60IDCHX2 installation instructions

Fisher & Paykel

Fisher & Paykel HP60IDCHX2 installation instructions

Respekta CH 22035 IXA Operating and installation instructions

Respekta

Respekta CH 22035 IXA Operating and installation instructions

Westinghouse WRC614SC Installation & user manual

Westinghouse

Westinghouse WRC614SC Installation & user manual

Pacific AC-Green Installation & user manual

Pacific

Pacific AC-Green Installation & user manual

KOBE Brillia INX27 SQB-700-3 Series Installation instructions and operation manual

KOBE

KOBE Brillia INX27 SQB-700-3 Series Installation instructions and operation manual

Becken BCHTS2340N instruction manual

Becken

Becken BCHTS2340N instruction manual

Omega ORU90XL quick start guide

Omega

Omega ORU90XL quick start guide

Atag ES902 MS Series Instructions for use

Atag

Atag ES902 MS Series Instructions for use

Beko CFB 6432 XGA user manual

Beko

Beko CFB 6432 XGA user manual

Broan E60000 SERIES installation instructions

Broan

Broan E60000 SERIES installation instructions

SCHOLTES HL 458 Instruction on mounting and use

SCHOLTES

SCHOLTES HL 458 Instruction on mounting and use

TJERNLUND VH1-6,8,10 VENT HOODS 8504054 REV B 0900 Owner's instructions

TJERNLUND

TJERNLUND VH1-6,8,10 VENT HOODS 8504054 REV B 0900 Owner's instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.