Teleco TMATE AL Series User manual

T-MATE App 868.3MHz
916MHz
868.3MHz
916MHz
TMATExxxAL/BL
*
115 mm
65 mm
25 mm
15 mm
DOC.: T770.06_EN
T-MATEXXXAL-BL DATE: 16/02/22
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
Bluetooth
TELECO AUTOMATION SRL
Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: +39.0438.388511 - www.telecoautomation.com
Product code
Characteristics
• Available in both 868.3MHz and 916MHz frequencies.
• Easy access via Bluetooth from any compatible device.
• Up to 50 programmable device commands.
• Possibility to create scenarios.
• Weekly timer to send commands at a specic date and time.
TMATExxxAL (power supply included)
TMATExxxBL
DIMENSIONS AND CONNECTIONS
Thermoplastic ABS
Not suitable for direct UV exposure
The product must be xed vertically.
The product guarantees IP54 rating
if properly assembled.
* The Blue Series receivers are bidirectional. They can receive
and execute commands and send the status back to T-Mate
T-MATE: 5VDC BLUETOOTH INTERFACE, PROGRAMMABLE BY MEANS OF AN APP, TO CONTROL ANY
TELECO PRODUCT.

A1234
A1234
Download the app T-Mate from App Store or Google Play. Check the compatibility with
your device rst. Once downloaded, it is possible to use it in DEMO mode, even without
any TMATE paired.
Pairing
Activate the Bluetooth communication on your device and power TMATExxxAL/BL ON.
Launch the T-Mate app.
Note: In the Android devices the localization function must be activated.
SETUP ROOMS
Open Setup menu ► Detecting boards, tap on “+”, insert the new installation name
and insert the Code of the T-Mate. Tap on “Connect“ button to pair the device.
Tap on the icon to enter in the
room. Set the name and assign
a picture amongst the 6 provided
or select a picture of your device
gallery.
Create new rooms accessing the
menu “Rooms” in Setup.
Tap “+” to add a room
ADDING COMMANDS TO A ROOM
Tap “+” to add remote commands.
Select the type of controlled device
from the list.
Name
Enable if the receiver
is Blue Series
Enable the timer
commands
List of available
commands
Add to
favourites
Note: swipe a listed room left to delete it.
Note: swipe a listed command left to delete it.
INSTALLATION

General
switch for all
the set timers
Set dates
Create new scenarios accessing the menu
“Scenarios” in Setup. Tap “+” to add a scenario.
Tap the
command
button to set
the timers
Open Setup menu ►
Devicename ► Schedule
to set system date/time. It’s
possible to set 2 groups
of days: weekdays and
weekend. Tap on the day
names to add in the groups.
SCENARIOS
Set the name and assign an icon amongst the 9 provided.
Tap “+” to add remote commands
from any room.
Select the type of controlled
device from the list.
Name
Note: swipe a listed scenario left to delete it.
TIMERS

A1234
When transmitters or
the wired input are
programmed, these
icons are ON
Once the scenario has been completed, it’s possible to assign it to a transmitter button or to a wired N.O. button
connected to the input 4-5.
Tap and press the transmitter button to assign.
Tap and press the transmitter button to delete.
Tap to delete all the associated transmitter buttons.
Enable/disable the scenario
recall on the wired input.
ADVANCED SCENARIO PROGRAMMING
Memorized
Smartphone
Open Setup menu ► Detecting boards ► Connect to “T-Mate” board ► Tap on “Backup“ button.
New
Smartphone
Open Setup menu ► Detecting boards ► Connect to “T-Mate” board ► Tap on “Restore“ button.
The smartphone must have an internet connection active.
Once the backup procedure has been completed close the T-Mate App.
Launch the T-Mate app.
The smartphone must have an internet connection active.
Launch the T-Mate app.
BACKUP FUNCTION
RESTORE FUNCTION

...
continuous
sound
12
EXAMPLE OF USE
Device commands: Home page ► Rooms ► select room ► select device command
Feedback
(tap to ask)
Feedback
(tap to ask)
Feedback
(tap to ask)
Feedback
(tap to ask)
Tap to go to
next preset
level
Keep
to dim
UP
Keep
to dim
DOWN
Tap to go to
next preset
level
Keep
to dim
UP
Keep
to dim
DOWN
14.2 MEMORIZATION
For its proper functioning the T-Mate transmitter must be memorized in the controlled receiver.
Refer to instruction manual of the receiver for the procedure of memorization.
Daisy transmitter
MEMORIZATION
T-Mate transmitter
14.3 REMOTE MEMORIZATION OF OTHER RADIO CODES FROM STANDARD TRANSMITTER
Note: The button P3 is located inside the standard transmitter. The added radio code will have the same functions as the code used for memorization.
This procedure is compatible with any type of transmitter.
1 s
P3
New
< 5 s
continuous
sound
Memorized
< 5 s
Memorized
Standard transmitter
Press button P3 of the memorized standard transmitter and hold. The buzzer emits a continuous sound. Press
a button relative to an already memorized code. The buzzer stops for 1 second and then starts the continuous
sound again. Press the virtual button on the Daisy transmitter relative to the new code to be memorized. Successful
memorization is indicated by the intermittent sound of the buzzer.
REMOTE MEMORIZATION OF OTHER RADIO CODES FROM STANDARD TRANSMITTER
Note: The button P3 is located inside the standard transmitter. The added radio code will have the same functions as the code used for memorization.
This procedure is compatible with any type of transmitter.
1 s
P3
New
< 5 s
continuous
sound
Memorized
< 5 s
continuous
sound
Standard transmitter T-Mate transmitter
Device commands can be found in the created rooms (1) or in the “favourites” list (2). If the associated receivers
belong to Blue Series (bidirectional technology), the status will be displayed aside.
Memorized
P3P3

Execute the
scenario
Status of the
single receivers
associated (if
part of Blue
Series)
TECHNICAL SPECIFICATION
Power supply 5 Vdc
Transmission frequency 868.3 MHz (TMATE868xL)
916 MHz (TMATE916xL)
Bluetooth module Bluetooth 4.1 (BLE) at 2.4GHz
Operating temperature range -20°C ÷ +50°C
Max. possible virtual transmitters 50
Degree of protection IP54
Material of the box and its lid ABS Thermoplastic
SCENARIOS
Home page ► Scenarios ► select scenario

IMPORTANT! READ CAREFULLY THESE INSTRUCTIONS BEFORE INSTALLING AND
COMMISSIONING THE PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
PRODUCT INSTALLATION
The product at issue must be installed, commissioned and maintained only by licensed and authorised people, respecting the
laws concerning the electrical installations. The manufacturer is not responsible for any damage due to wrong installation or
improper use.
SAFETY INFORMATION
The radio signal reception of the device could be disturbed by the presence of electrical disturbances being transmitted by
other appliances working on the same frequency or if the product is somehow shielded by metal parts. Do not use the device
in places or where systems are sensitive to radio emissions (e.g. airports, hospitals). The operator is in no way protected
against interference from other telecommunication equipment or systems (e.g. authorised radio systems working on the same
frequency range). If you are having problems with its range of action, x the device up high.
The manufacturer, Teleco Automation s.r.l, declares that the type of radio equipment is compliant with Directive 2014/53/EU.
The full text of the EU compliance declaration is available at the following Internet address: www.telecoautomation.com/ce.
In the view of a constant development of their products, the manufacturer reserves the right for changing technical
data and features without prior notice.
INFORMATION TO USERS under art. 14 of the 2012/19/EU DIRECTIVE OF THE EUROPEAN PARLIAMENT AND COUNCIL of
4 July 2012 on waste electrical and electronic equipment (WEEE). The crossed bin symbol on the equipment, or its packaging,
indicates that the product must be collected separately from other waste at the end of its useful life and not with mixed urban
waste. Please contact your municipality, or local authority, for all information regarding the waste sorting systems available
in the area. The retailer is obliged to collect the old equipment free-of-charge when the customer buys a new equivalent
equipment. This is to encourage correct recycling/disposal. Appropriate waste sorting for the subsequent recycling,reatment
and disposal in an environmentally sound way of the disused equipment avoids negative eects on the environment or
human health and favours the re-use or recycling of the equipment’s materials.
According to FCC regulations, the device is designed as a mobile station.”
“This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
“During its normal function, keep a distance of at least 20 cm from the radiant element.”
Any changes or modications not expressly approved by the party responsible for compliance could void the User’s authority
to operate the equipment”.
According to ISED regulations, the device is designed as a mobile station.”
“This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.”
“During its normal function, keep a distance of at least 20 cm from the radiant element.”

TELECO AUTOMATION OCEANIA PTY LTD
AUSTRALIA
Tel. +61.(07)5502.7801
info@telecoautomation.com.au
TELECO AUTOMATION BENELUX SPRL
BELGIUM
Tel. +32.67561967
info@telecoautomation.be
This document is the property of Teleco Automation Srl, which reserves all reproduction and copyrights
TELECO AUTOMATION S.R.L.
ITALY
Tel. +39.0438.388511
info@telecoautomation.com
TELECO AUTOMATION FRANCE
FRANCE
Tel. +33.(0)472.145080
info@telecofrance.com
TELECO AUTOMATION GMBH
GERMANY
Tel. +49.(0)8122.9563024
info.[email protected]
TELECO AUTOMATION IBÉRICA S.L.
SPAIN
Tel. +34.966.16.82.24
Other manuals for TMATE AL Series
1
This manual suits for next models
1
Table of contents
Other Teleco Controllers manuals