TeleDart RD706 User manual

Injection Applicator RD706
Dear Customer,
Be sure that we stand with all our energy and passion behind our products and that your decision for teledart ® was the right
one. We look forward to assisting you with words and deeds during a long period of time and to offering you the service you can
await for a quality product. Our conviction and our confidence in our products allow us to guarantee you the function of your
applicator for the next 20 years.
Please study the following operator’s manual carefully and follow all our directions and instructions. Then you will be sure to do
your remote injections safely and without problems.
We wish you always very successful operations.
The Team of teledart ®
Pressure table for the teledart® applicator RD706
This applicator has been tested in a closed area.
Please note that this is only a guideline, which may differ from your own shooting results as wind and weather
conditions as well as the shooting skills of the user can change these results considerably.
barrel
caliber / mm Syringe dart Distance Pressure Iron sight OP1
Telescopic sight
OP2
Red dot
15 m bar
15 m bar
15 m bar
15 m bar
15 m bar

Equipment feature
1 Cartridge holder for CO2-16 g.
2 Pressure supply
3 Trigger
4 Trigger safety knob
5 Safety valve
6 Adjusting nuts for cheek piece
7 Screw for shoulder piece
8 Shoulder piece
9 Cheek piece
10 Threaded loading cap
11 Pressure gauge
12 Mounting rail with standard sight
13 Barrel fixing
14 Barrel with quick coupling
15 Front sight
Technical data
Weight 3 kg with aluminum barrel
Total length with barrel 113 cm
Material aluminum/ stainless steel/ brass
Barrels/Syringe volumes interchangeable barrel system with quick connection coupling
Calibre 11 mm (0,5 - 10 ccs/ml), Calibre 13 mm (1 - 20 ccs/ml)
Mounting rail for optic sights yes
Effective range (with standard barrel calibre 11 mm, 3 ml syringe) 1-70 meter (depending on dart
sizes)
Standard sight back sight/front sight
Pressure build-up CO2 cartridge (16 bar) or air pump (11 bar)
Pressure control continuous (0 - 16 bar)
Safety striker yes (rotary knob safeguard)
Safety valve yes
Pressure relief valve yes
Kinetic energy > 7,5 joules
Target zone 130 meter

Scope of delivery
Please check upon receipt of our delivery, if your consignment is:
complete
corresponds to the ordered equipment
undamaged
Please inform us immediately, latest 48 hours after receipt of goods if you have any damage by sending us a letter/ fax or e-mail.
Our service team will immediately handle your claim.
Safety advises
Always point the applicator in a safe direction. Never point at other people even if your applicator is not loaded.
Always keep your applicator with the barrel down to the ground.
Keep your applicator in safe until you intend to shoot.
Be aware that the applicator has a danger zone of almost 150 meters. Be sure that no other persons are inside this area and
that there are no public alleys, streets or squares.
Collect all used darts and part of darts after use, even if they are empty or damaged.
Avoid that children and other unauthorized individuals come into possession of darts or part of darts.
Clean used darts and part of darts before disposing of them.
Never use drugs or alcohol while handling this product.
Never use our applicators with pure oxygen (e.g. oxygen cartridges)!
Of course, all regulations applicable in your country with regard of the handling of weapons as well as animal protection and
welfare are valid. Follow strictly the all safety advices of the drug producer.
Noticeable damages
For noticeable damages, which are caused by improper handling of the applicator by other extraneous
causes the use of the applicator must be stopped immediately. In such case first the barrel and second
the dart must be removed and the applicator completely depressurized. This happens by careful removal
of the CO2- cartridge or air pump connector first and is followed by the complete depressurizing of the
pressure chamber. For further instructions please contact your dealer or us directly.

Handling and use
Before first use
Make yourself familiar with all operation elements of your applicator before you attempt to test the applicator and go into
practice.
Teledart rifles enable various fitting possibilities, so that you can adjust the rifle position to your needs.
Before shipment, we test all teledart ® applicators at a distance of 15 m (16.41 yds),
using a teledart ® training dart T3-11 3 cc or T5-13 5 cc.
Training darts are available in many sizes. If you need a size we have not got on our pricelist, please contact us. We can produce
it to your requirements. Note all pressure values in the pressure table which is part of your manual.
Assembling
Slide in the barrel as far as it goes. Take care that the sight is on your right hand side. As soon as the barrel has reached its
position, turn the barrel a quarter (90°) to the left until the guiding pin situated at the barrel retainer ring locks.
Individual Settings
Adjust the shoulder - and the cheek piece to a comfortable position for you. If you use an optic sight, also adjust this to your eyes.
Inserting the CO2 cartridge
Unscrew the cartridge holder and insert a CO2-cartridge. Tighten up the cartridge holder until the cartridge is tapped.
Only replace opened cartridges if they are completely empty. Further, all safety advices marked on the packing of the CO2-
cartridges are valid. TeleDart does not take any liability for damages and injuries caused by improper handling of CO2-
cartridges.
Safety knob
Check if the safety device of the trigger is on “safe”. The turning knob must be turned to the upper position (Pos. “S”).
Pressurizing
The pressure regulation knob must be turned by one third from 0- Position.
Observe the manometer and release the knob when you have got the desired pressure. The pressure regulation knob returns
automatically to the 0-position.
If you have got too much pressure, you can correct this easily. Just turn the pressure
regulation knob in direction of the “-“ position until you have got the desired pressure.
The pressure regulation knob does not return automatically to the 0-position if you release pressure. It has to be turned back by
hand.
The safety valve is engineered to protect your applicator from damages caused by dangerous
overpressure. The exceeding of the particular maximum pressure into the red marked area of the
manometer can cause damages to your applicator. Damages to material, which are proven to be caused
by deliberate exceeding of maximum pressure ceases our guarantee. Manipulation of safety valve also
immediately ceases our guarantee and in this case we do not take any liability for damages to persons,
animals or material.

Loading of dart syringe
Unscrew the loading screw and insert the syringe into the barrel from behind.
Push the dart syringe inside the barrel using the positioning pin situated at the loading screw. Make sure the loading screw is
tightened properly.
Shooting
The applicator is now ready for shooting. The safety lock can now be deactivated. Turn the safety knob into position “F”.
Now aim at your target. The trigger has got a trigger pressure point which allows precise shooting. Please ensure to pull the
trigger fully to make sure that the dart reaches necessary speed. After shooting, turn the safety knob immediately into position
“S”.
Care
You can clean the applicator with a moist cloth if the applicator gets dirty.
Never use chemical cleaners.
Check if there is dirt inside the barrel. If necessary brush it dry with the cleaning tool.
Grease the barrel on the outside where it gets pushed into pistol so it can slide easily.
Steel barrel has to be oiled inside against rusting with Ballistol oil included in scope of delivery.
Maintenance
Special maintenance is not necessary.
Transport and storage
For storage and transportation all legal requirements must be complied with.
Always store the applicator at a dry place. CO2-cartridges can remain in the applicator.
If you store the applicator, the pressure regulation knob must be in the “-“-position to avoid an unintended pressure built-up.
Please check the function of your applicator if you have not used it for a longer time.
Optional equipment
Here you find a summary of optional equipment for your applicator:
OP1 Telescopic sight
OP2 Red dot sight
RF Range finder
AR/AC
Adapter for 45 g or 12 g cartridges
FP Air pump (Stand up pump to max. 11 bar)
TP Air pump (Foot pump to max. 7 bar)
HP Hand pump
CASE Rifle case
Hard case 125 x 38 x 12 cm

Guarantee
Teledart ® Guarantee and Warranty Conditions (E)
Our applicators pass several quality controls. To strengthen your trust into our product, in addition to your legal rights,
teledart ® guarantees:
1. For this product we give you a function guarantee of 20 years. The guarantee begins on the day of purchase of the final
user.
2. Should the product show defects within the guarantee period, it will be repaired or replaced by teledart ®. Replaced parts
will be in our possession. Further demands are not accepted.
3. Under the following rules we repair or replace damages or defaults of the product, which are proven to be caused by a
material or manufacturing default.
4. Should you make a claim, please contact your teledart ® specialist dealer or us directly. You find the address in the user
manual or on our web site www.teledart.com. The guarantee ends immediately if repairs or any manipulation of the product
are made by none authorized persons or if you use spares, change parts or add accessories which are not of teledart’s
original production and which then cause a damage.
5. Products for which you make a claim have to be send or given over to the seller or to a teledart ® specialist dealer. You
must insure the dispatch or bear the costs for any loss or damage incurred. Cost of transport will not be paid for by teledart.
6. If you make a guarantee claim, please add the fully completed guarantee documents as well as a proof of the original
purchase within the guarantee period for your specialist dealer. The guarantee claim must clearly illustrate the complaint,
presuming that it is based on a specific defect demonstrated by facts and when the defect occurred. Further, the complete
serial number of the applicator must be readable.
7. A guarantee claim will not be accepted for damages, which are irrelevant for the value or the use of the applicator, which
are caused by irregular environmental conditions, unprofessional use or use which is not in accordance with regulations. If
the points in the user and maintenance manual are not observed a guarantee claim will not be accepted. Wearing parts are
exempt from guarantee.
8. Should the applicator be used in another country than the country it had been developed and produced in, it may be that
some technical changes are necessary to adopt the applicator to the technical resp. security norms of this country. These
changes are not caused by material or manufacturing default and are not covered by this guarantee. Costs for such
changes or damages this may cause are not reimbursed.
9. The guarantee is a product guarantee and can be claimed during the guarantee period by any person who has purchased
the product in a legal way. The legal right of the buyer following the national legally applicable rights, resp. the rights of the
buyer as a part of the purchase contract as well as other rights are not affected by this guarantee. As far as the national law
does not require other, the claims are restricted to the points named in this guarantee. Teledart and all specialist dealers
are not liable for indirect resp. subsequently loss or injuries on persons or animals or for the loss of dart syringes, needles
or drugs.
10. Guarantee claims do not extend the guarantee period nor do they lead to a new guarantee period. The guarantee period for
all built-in spare parts finishes at the moment when the guarantee for the complete applicator finishes. In case of a
replacement teledart ® can determine a new time of guarantee which can be restricted under consideration of the time of
use of the replaced applicator.
11. We do not assume liability for further or other claims, especially for those caused by damages which are not created by the
applicator– if such a claim is not mandatory law.
12. These guarantee rules are valid after 03.05.2023.
Please consider as well our additional after-sale service.
Even after expiration of the guarantee TeleDart ® or our specialist dealers are always at your disposal.
If you decide for TeleDart ®, you will always get a good service.
teledart GmbH & Co. KG,
Obere Heide 8
67368 Westheim / Germany
Tel.: +49 (0)6344 939765
Whatsapp: +49 (0)1575 3254319
E-Mail: info@teledart.com
Internet: www.teledart.com
Table of contents
Other TeleDart Laboratory Equipment manuals
Popular Laboratory Equipment manuals by other brands

SCHEU
SCHEU BIOSTAR Operation manual

Agilent Technologies
Agilent Technologies 1260 Infinity II user manual

NuAire
NuAire Labgard NU-427-400 Operation & maintenance manual

Waters
Waters APGC Operator's guide supplement

BioCare Medical
BioCare Medical intelliPATH FLX manual

ZINEXTS
ZINEXTS ZiXpress 64 DX system instruction manual

Microchip Technology
Microchip Technology PD-9601-zzGC/AC user guide

conoptics
conoptics 302RM manual

Agilent Technologies
Agilent Technologies IDP3GBKIT Quick reference guide

Nippon Genetics
Nippon Genetics FASTGENE ELECTRONIC PIPETTE-200 manual

Steris
Steris AMSCO 400 Series Operator's manual

Organomation
Organomation N-EVAP 11106-O instruction manual