On the Wireless Protocol Suite Toolbar, clicking on the Stop Record button, or selecting Stop Recording from the
Capture menu options will halt live capture. From the Main window you can click the Stop Record button or
select Stop Recording from the Capture menu list to stop recording as well.
The Device Database View populates with any newly discovered devices. Selecting devices for analysis can be done while recording.
The Security View will show all encrypted Bluetooth links.
The Event Log View will begin to populate with information, warnings, and error messages.
The Status Bar will show a running total of captured packets.
Note: Starting a new capture session will clear all unsaved data from both the Sodera hardware and the
Wireless Protocol Suite. If it has not been saved, then a pop-up warning message will appear.
8. Selecting Devices for Analysis
Once a capture session starts by clicking on Start Record on the Main Window Toolbar, data from all active devices within range or
data from wireless or wired connections is being captured. To analyze the data using the Wireless Protocol Suite, select specific
devices of interest to include in the analysis.
In the Device Database view, place a check in the row of each active device to be analyzed. Active devices can also be selected
while the recording is in process.
Note: Data filtered by the device selection is an “OR” function, not an “AND” function. When selecting device1,
device2, device3,... the recorded data filtered into the analyzer is data involving device1 OR device2 OR device3
OR .... However, if in the Options menu, analysis of LE Empty packets is selected, an AND function is included.
For example: (device2 AND LE Empty packets) OR (device3 AND LE Empty packets).
The following table lists some common data capture and device selection scenarios.
Once Devices are selected, analysis of the capture can begin.
9. Starting Analysis
The analysis begins by clicking on the Start Analyze button in the Wireless Protocol Suite Main window. The
Sodera LE analyzer will begin sending captured packets involving the selected device to the Wireless Protocol
Suite.
Once analysis has begun, you cannot change the device selection. All device rows in the Device DatabaseView are
grayed-out. To stop the analysis, click on the Stop Analyze button. You can then change your device selection and
restart analysis by clicking on the Start Analyze button.
To stop the analysis, click on the button in the Sodera datasource or click the button on
theWireless Protocol Suite Main window You can also select the Stop Analyze option in the Capture menu in the Sodera datasource
or Stop Analyzing option in the Capture menu in the Main window as well.
Conducting analysis from a capture file is identical to the live capture method.
Wireless Protocol Suite: Main Window
Wireless Protocol Suite: Main Window