Televes CoaxBox User manual

Ref.769330
CoaxBox User Guide
EN

Important Safety Instructions...................................................................................................................................3
Introduction.............................................................................................................................................................. 4
CoaxData CoaxBox................................................................................................................................................................4
Other CoaxData devices.........................................................................................................................................................5
CoaxBox Package content......................................................................................................................................................6
Knowing CoaxBox................................................................................................................................................... 6
Device Connections................................................................................................................................................................6
LED device..............................................................................................................................................................................7
Installing CoaxBox................................................................................................................................................... 8
Configure CoaxBox................................................................................................................................................. 9
CoaxBox Web.........................................................................................................................................................................9
CoaxBox Administration Web...............................................................................................................................................10
Device access via ssh...........................................................................................................................................................10
Configure network interfaces................................................................................................................................................11
Security Considerations........................................................................................................................................................13
Operating Considerations.....................................................................................................................................................13
User Account Management..................................................................................................................................................13
CoaxBox services.................................................................................................................................................. 14
CoaxProv............................................................................................................................................................... 14
Web interface........................................................................................................................................................................15
Calculation of storage capacity.............................................................................................................................................16
Install/Uninstall CoaxProv service.........................................................................................................................................17
Documentation......................................................................................................................................................................17
CoaxData AccessControl......................................................................................................................................18
Installation diagram...............................................................................................................................................................18
Main Features.......................................................................................................................................................................18
AccessControl Web interface................................................................................................................................................19
Enable/Disable AccessControl Service.................................................................................................................................19
Documentation......................................................................................................................................................................20
CoaxBox Characteristics....................................................................................................................................... 20

CoaxBox - User Guide Ref.769330
3
Important Safety Instructions
Before handling or connecting the equipment, please read this manual!
This equipment has been built in accordance with international safety standards.
Dispose of electronic devices you no longer need in a respectful way with the environment and in accordance with
the relevant regulations.
Please read the following safety tips carefully.
POWE :
Adapter ~ 1 8-254V 5 / 6 Hz, 12V output .7A.
The base socket must be near the equipment and easily accessible.
OVE LOAD:
No overload electrical, extensions or adapters to avoid the risk of fire or electric shock.
LIQUIDS:
Do not expose the adapter to the fall or splashing water.
Not place containers containing liquids near of equipment.
SMALL OBJECTS:
Avoid proximity of small metal objects. They could enter in slots or connectors on the computer and cause serious
damage.
CLEANING:
Unplug the network adapter before cleaning.
Using a soft cloth, moistened in water (without detergents) to clean the outside of the machine.
VENTILATION:
Place the computer in a place all right ventilated with uncovered slots.
Avoid exposure to sunlight, heat sources or flames (such as burning candles).
Do not place other equipment on top.
CONNECTIONS:
Perform only recommended to prevent possible damage connections.
LOCATION:
Place equipment in a protected inner place to avoid electric shocks, rain or direct sunlight.
COMPLIANCE IN ELATION TO HUMAN EXPOSU E TO ELECT OMAGNETIC FIELDS
Safety information
This product has been evaluated in relation to RF exposure in humans with reference to the limits set by the
ICNIRP (International Commission on Radiation Protection Non-Ionizing). For low power transmissions,
evaluation was based on EN 62479. For other wireless transmissions, evaluation has been based on EN 5 385,
determining a limit under 2 cm.
Installation instructions
Install the device with a minimum distance separation of 2 cm from the areas where people normally remain
sure.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
This symbol indicates that equipment meets the
CE marking requirements
This symbol indicates that this product can not
be treated as conventional household waste.
Make sure product is disposed of correctly.
This symbol indicates that equipment meets
the safety requirements for Class II
equipment
This symbol indicates that the equipment meets
the safety requirements for Class II equipment

Televes
4
Introduction
CoaxData CoaxBox
CoaxBox, ref.76933 , is a device with preinstalled software to manage CoaxData networks. It allows the
provisioning and monitoring of Coaxdata networks in a simple and intuitive way.
Technical feature:
CoaxBox incorporates a powerful iMX.6 ARM quad-core CPU at 1Ghz that allows management and
monitoring of one or more CoaxData networks.
Gigabit Ethenet connector 1 BASE-T to connect device to the installation
RJ9 power connector, with a flange which prevents accidental disconnection.
ef.769330 Block Diagram
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
RJ45
RJ45
ARM Corte A9
ARM Corte A9 Ethernet
Gigabit
PHY
Ethernet
Gigabit
PHY
SPI
NOR Flash
16MBytes
SPI
NOR Flash
16MBytes
Power
Management
Power
Management
EMMC
NAND Flash
4Gbyte
EMMC
NAND Flash
4Gbyte
DDR3
1GByte
DDR3
1GByte
64bits SPI SDIO
RGMII
12Vdc
12Vdc

CoaxBox - User Guide Ref.769330
5
Main features
Monitoring the state of coaxial network through the Access Control application.
Monitoring and provisioning of the devices 7693 1 by CoaxProv application.
It has three LEDs to indicate that the device is properly accessing Internet and indicates services are
running correctly.
System Requirements
The system is Plug and Play and requires no additional software or driver.
To use this device requires a PC with an Ethernet interface.
Support HTML5 Web browser. Mozilla Firefox or Google Chrome are strongly recommended.
Other CoaxData devices
Ref.76933 complements CoaxData 1Gbps products family:
•Ref.7692 1 CoaxData ™ 1Gbps-HDTV
•Ref.7692 2 CoaxData ™ 1Gbps SFP-HDTV With
•Ref.7692 3 CoaxData ™ 1Gbps-HDTV 1XEth
•Ref.7693 1 CoaxData ™ 1Gbps-HDTV Coax + Wifi
•Ref.76922 CoaxData ™ TV-Data Filter diplexer 2-68 MHz / 87-215 MHz
•Ref.76921 CoaxData ™ SFP optical adapter 1 Base-X 2 FO
Ref.76920 CoaxData ™
Gbps HDTV
Ref.769202 CoaxData ™
1Gbps HDTV con SFP
Ref.769203 CoaxData ™
Gbps HDTV xEth
Ref.76930 CoaxData ™
Gbps-HDTV Coax + Wifi
Ref.7692 0 CoaxData ™
SFP Module 000 Base-X
Ref.769220 CoaxData ™ Gbps
diplexer filter TV-Data 2-68 MHz /
87-2 50 MHz
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
6
CoaxBox Package content
1CoaxData CoaxBox
212VDC power supply with RJ9 connector
Knowing CoaxBox
Device Connections
xEthernet RJ-45
Ethernet connector 1 BASE-T for Connect CoaxBox to a PC or laptop. It allows autonegotiation with the host for
maximum link speed and Auto-MDIX which avoids using Ethernet crossover cables.
RJ9 Power connector
12Vdc connector powers the device for operation. RJ9 connector is equipped with a flange which prevents power
being accidentally disconnected.
Power Switch Off
Use power switch to turn on/off device. LED on the front that indicates when device is on and working.
SDCard Expansion Slot
Allows to increase storage capacity of the CoaxBox. By default, storage capacity is 4GB corresponding to internal
eMMC. Use this slot to increase capacity.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
1xEthernet Port
1 Base-TX
Power Switch
On/Off Power RJ9
12Vdc, 25 mA

CoaxBox - User Guide Ref.769330
7
LED device
Power Led
It indicates that device is correctly power:
•Green: The device is on and working.
•Off: The device is not on. Check switch position and device is powered via RJ9 connector supply.
Led Services
This LED indicates that CoaxBox services are running correctly:
•Green:Host Services are running OK.
•ed: Management Services are failing or are not running properly.
Led Internet
This LED indicates status of internet connection:
•Green: Indicates that device has Internet access.
•Off: Indicates that the device does not have Internet access. Check device connections, if LED still keep
off check Internet access provided by your ISP.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
Power Led
On/Off Services Led
Verde: Services OK
Rojo: Services Fail
Internet Led
On: Internet OK
Off: Internet Fail

Televes
8
Installing CoaxBox
The figure shows an installation e ample of Coa Bo in a managed Coa Data network
•Coa Bo is installed at the coa ial headend and connected directly to the Coa Data master or via an Ethernet switch.
Coa Bo will search for devices and process the received reports to send alarms to installer via email or SNMP.
•ref.769301 Slave devices has an active SNMP Agent. It should be configured to send reports to the Coa Bo .
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
Internet
Router
Snmp
Agent Snmp
Agent
TV
Headend
769201
Master
TV TV
Snmp
Agent Snmp
Agent
Snmp
Agent Snmp
Agent
data
TV
TV+ data
ref.769330
CoaxBox
CoaxData
Management

CoaxBox - User Guide Ref.769330
9
Configure CoaxBox
Device has an Ethernet interface with two IP addresses:
•eth : Interface is pre-configure as active DHCP client.
•eth0:1 : Alias Interface with fi ed 169.254.1.254 IP Address.
CoaxBox Web
Device has a Web Service running on port 8 , all services running inside CoaxBox are available on this web and
redirect to proper service when click on button.
Following services are avallabe:
•Administration Web: Redirects browser to CoaxBox Web Administration(port 15712)
•CoaxProv: 7693 1 Device Management (port 1571 )
•AccessControl: Coaxdata Device Management (port 157 8)
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
0
CoaxBox Administration Web.
For device network configuration and another administration tasks, a Web service running on 15712 port is
available.
Use the following account to access to CoaxBox web service
Device access via ssh
The most immediate way to access to device is via ssh. To do this configure the host IP 169.254.1.253/24 and
perform the following ssh command to access.
$ sshpass -p 76Coax93Box30 ssh -o StrictHostKeyChecking = no root@169 254 1 254
coaxdataservices root @: ~ #
SSH Terminal can execute any command on the CoaxBox such as install new packages, remove/add services or
restart device.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
CoaxBox Management Web
Web: http://169.254.1.254:15712
Usuario/User: Admin
Password: Televes1

CoaxBox - User Guide Ref.769330
Configure network interfaces
To change the configuration of the eth interface to assign an static IP instead of DHCP interface; Go to
Network>Network Interfaces on Web interface
This shows device interface's list
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
2
Click on eth , select the static settings and press Save to save interface configuration
On the menu Network Interfaces, select eth and click Apply Selected Interfaces, to apply previously saved
configuration.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

CoaxBox - User Guide Ref.769330
3
Security Considerations
Please note that access to the CoaxBox should be restricted.
•The firewall has not been enabled.
•Admin access account root/76Coax93Box3 is public, as this manual. Changing this password should be
done prior to any further configuration.
•User Access Account Admin/Televes1 is public, as this manual. Changing this password should be done
prior to any further configuration.
Operating Considerations
Consider the following notes about CoaxBox services:
•Maximum number of reports that CoaxBox can process is 6 reports/minute. Please check number of
CoaxData devices and report interval to avoid exceeding this value.
•If you install multiple CoaxBox in your CoaxData network, only one CoaxData AccessControl can be
running on each broadcast domain. Enable Access Control only on one CoaxBox.
User Account Management
For security reasons use could consider to change user/system account's password. Please, go to System >
Change Passwords on Web management.
Select account, and change the password
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
4
CoaxBox services
CoaxBox comes with severeal preinstalled services:
•CoaxProv: Application for ref.7693 1 management.
•CoaxData AccessControl: Application for CoaxData management .
CoaxProv
CoaxProv™ is a tool to manage ref.7693 1 devices. With CoaxProv™ provision and monitor 7693 1 devices is
easy. You can also check status of coaxial and wireless networks as well and generate alarms when a malfunction
is detected.
This application is developed specifically for OEMs and network operators who need to remotely manage CoaxData
devices and check the status of the network in real time.Installation diagram
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
Internet Router
769301
Snmp
Agent
769301
Snmp
Agent
TV
Headend
769201
Master
TV TV
769301
Snmp
Agent
769301
Snmp
Agent
769301
Snmp
Agent
769301
Snmp
Agent
769330 CoaxBox
with CoaxProv
Enable Snmp agent on 769301.
Configure Trap Destination and
Port to report to CoaxProv.
Send reports every Snmp Report
Interval on seconds.
data
TV
Ref.769330 CoaxBox
with Coa Prov

CoaxBox - User Guide Ref.769330
5
Main features CoaxProv™
•Upgrade 7693 1 firmware and configuration.
•Support for massive operations to upgrade firmware or configuration of multiple devices.
•Embedded TFTP server to Provision device with DHCP protocol options 66 and 67.
•Discovery of local 7693 1 devices with LLDP layer-2 protocol.
•Discovery of remote devices with IP scanning.
•Configure devices to send reports to CoaxProv and record reports on an internal database.
•Monitor device wifi links and provide info of device VAPs and Wifi stations connected.
•Monitor device resources like interfaces, CPU. memory and disk.
•Monitor Coaxial links and provide info of Coaxial Rate, Signal to noise and Attenuation.
•Monitor Wifi links and provide info of stations connected to VAPs and VAP state.
•Monitor device status and provide list with CPU, memory and disk usage.
•Create Graphics with all device info collected.
•Generate device alarms when device stop to send reports to CoaxProv or cannot load device configuration.
Track device activity with device events.
•Automatic generation of e-mails or snmp traps that enable propagate alerts to operator monitoring
system for major incidents. To avoid alarm flooding, email or trap alarm must match rule on alarm filters,
so only specific alarms are propagated to external monitor system.
•Device Groups. Grouping devices help to track and avoids long lists with a lot of devices, also help to
locate device when grouping by building block or hotel floors.
Number of device reports cannot exceed 600 reports/minute!
In your monitoring needs exceed that amount, It is recommended the installation of multiple
CoaxBox devices on your network and segment network management.
Calculate storage needs for application or use an external SD!
Ref.76933 box has an internal 4GB eMMC. Depending on the number of reports/minute and
time to keep reports in database, device storage capacity can be exceeded. If storage needs
exceed capacity, CoaxProv detects it and sends an alarm, eliminating the oldest reports.Use an
external microSD to avoid this. Simply insert the microSD card into expansion slot and restart
your system. On boot, internal DB is copied automatically to external microSD card and new
reports are stored on it.
microSD Card must have only one partition with Ext4 filesystem.
Web interface
The first step you must take the installer is set CoaxProv. This step is performed via Web port 1571 .
•Opening a browser and indicate the address: http: // <CoaxBox_IP> : 1571
•Use the following account
user: Admin
password: Televes1
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
6
Calculation of storage capacity
An important parameter of CoaxProv is the calculation of storage needs. Ref.76933 has a 4GB on internal eMMC,
but in the case that available space is exhausted the CoaxProv emits an alarm and deletes the oldest records.
This capability is controlled by the configuration parameters of the Provision Database> Provision Configuration>
Database Configuration
As seen in the image, device reports are stored for 24 hours. The consumption of each report in the database is
1KByte/report. So if we have a system with 6 devices, sending a report every minute, the storage capacity per
day will be:
1KB/report x 600 reports/minute x 60 min/hour x 24 hhour = 864000 KB = 864MB/day
Changing the time that reports are stored on system (Keep Records For Last) from 24h to 1 week, the need for
storage will be:
864MB/day x 7days =6,04GB
The value required for storage is 6GB, exceeding the internal capacity of 4GB.
To increase the storage capacity insert an external microSD into the expansion slot of the device. microSD Card
must have only one partition with Ext4 filesystem. Reboot the system using the Administration Web on port
15712: System>Boot And Shutdown>Reboot System.
On boot system will detect that there is an microSD and will install internal database on EMMC on SD, without risk
of information will be lost.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

CoaxBox - User Guide Ref.769330
7
Install/Uninstall CoaxProv service
By default the CoaxProv starts when the unit does. Service configuration can be performed via Web Administration
interface on port 15712.
Go to System > Bootup and Shutdown, select service called provisioning
•Start/Stop/ estart to start / stop the service.
•Start on Boot: Starts the service at boot
•Disable On Boot: Disables the service at boot
•Start Now and On Boot: Starts the service at startup and now.
•Stop Now and On Boot: Starts the service at startup and now.
The same task can be performed through an SSH connection. Commands below shows how to configure this
service through a terminal.
# To start the service
coaxdataservices root @: ~ # /etc/init d/provisioning start
# To stop the service
coaxdataservices root @: ~ # /etc/init d/provisioning stop
# To install the service (it will start when CoaxBox is started)
coaxdataservices root @: ~ # update-rc d provisioning 50 defaults 20
# To remove the service (serice will not start when you start CoaxBox)
coaxdataservices root @: ~ # update-rc d -f provisioning remove
Documentation
Next table shows CoaxProv documentation for Web interface and 7693 1 SNMP agent. Check your CoaxData
documentation or contact with your Televes support.
Document Language Description
CoaxProv_User_Guide_ 3_ES SPANISH Manual CoaxProv
CoaxProv_User_Guide_ 3_EN ENGLISH Manual CoaxProv (EN)
DoC-AN_CoaxData_ref7693 1_Snmp_Support_ 2_ES SPANISH Ref.7693 1 SNMP Agent
DoC-AN_CoaxData_ref7693 1_Snmp_Support_ 2_EN ENGLISH Ref.7693 1 SNMP Agent (EN)
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
8
CoaxData AccessControl
The application CoaxAccessControl™ allows setting CoaxData™ devices in a simple and intuitive way to
establish different parameters of access to coax medium, check installation status and link quality between
devices.
Installation diagram
Main Features
Configure the access mode of the coaxial modems CoaxData1Gbps the medium such that can enable /
disable a device and set parameters such as access bandwidth and user limit modem.
check installation status determining the rate links between different devices.
Alarm generation to notify the user of any impact on the system as a link loss of a device or poor
quality, and access to the current network situation by implementing an SNMP agent.
The system configuration can be done by SNMP protocol or through a simple Web interface for users
without technical knowledge of this protocol. For this it provides a complete specification MIB defines all
SNMP objects implemented by SNMP agent.
Automatic generation of e-mails that enable ongoing monitoring and warning for major incidents in
both the management system itself as devices to manage.
Multiple CoaxData AccessControl on the same network segment are not allowed!
Depending on the characteristics of your network, you may need to segment the monitoring
and install several CoaxBox in your installation. Only one AccessControl can be enabled.
See bellow instruction to enable/disable AccessControl con CoaxBox.
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

CoaxBox - User Guide Ref.769330
9
AccessControl Web interface
The first step required of the installer is to configure the access control system indicating operating parameters.
This step is performed via un port Web.
•Opening a browser and indicate the address: http: // <CoaxBox_IP> : 157 8
•Use the following account to access.
user:Admin
password: Televes1.
Enable/Disable AccessControl Service
By default CoaxBox start AccessControl service at startup.
Use the Web management to configure this CoaxBox service. Go to System> Bootup and Shutdown select
service called coaxdataaccesscontrol and click on start/stop/install/uninstall button.
Multiple CoaxData AccessControl on the same network segment are not allowed!
In case there are several AccessControl applications running on the same network segment,
use service options to disable service on all CoaxBox except one.
Service can also be configured through ssh terminal.
# To start the service
coaxdataservices root @: ~ # /etc/init d/coaxdataaccesscontrol start
# To stop the service
coaxdataservices root @: ~ # /etc/init d/coaxdataaccesscontrol stop
# To install the service (it will start on CoaxBox bootup)
coaxdataservices root @: ~ # update-rc d coaxdataaccesscontrol 50 defaults 20
# To remove the service (it will not start on CoaxBox bootup)
coaxdataservices root @: ~ # update-rc d -f coaxdataaccesscontrol remove
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es

Televes
20
Documentation
AccessControl has documentation for Web interface and SNMP agent. Consult your CoaxData documentation or
contact with Televes Support to get following docs:
Document Language Description
AccessControl-Manual_Web_ 1-ES SPANISH Web Access Control Manual
AccessControl-Manual_Web_ 1-EN ENGLISH Web Access Control Manual (EN)
AccessControl-Manual_Snmp_Agent_ 1-ES SPANISH Access Control Snmp Manual
AccessControl-Manual_Snmp_Agent_ 1-EN ENGLISH Access Control Snmp Manual (EN)
CoaxBox Characteristics
CPU Processor Cortex A9 Dual Core (i.MX6 DualLite)
Storage DDR 1 GByte DDR3
eMMC 4GBytes eMMC (solid-state drive)
Flash 16MBytes NOR SPI (Boot)
Interfaces Feeding RJ9 12V DC
Ethernet RJ45 1 /1 /1 Base-T Ethernet. Autocrossover.
Micro SD Slot Micro SD connector
Leds Led Led Power
Led Led Internet
Led Led Service
Services CoaxProv™
CoaxData AccessControl™
Directives CE UNE-EN 60950-1: 2007 / AC: 2012: product safety
UNE-EN 55022: 2008 radio interference
UNE-EN 55024: 2011 immunity requirements
account access Default IP address 169.254.1.254
root account user:root Password:76Coax93Box3
Admin account User: Admin Password: Televes1
OS Linux Linux kernel 3.1 .53 or higher
Power Power Adapter 1 8 - 254V ~ 5 / 6 Hz /// 12V - .7A
Consumption 12V - 25 mA, 4W
Temp range. -5 ... +45 ° C
Dimensions 165 x 12 x 48 mm
Weight 475 g
ENGLISH
2017 © Copyright, Televés S.A. www.televes.es
Table of contents