Tempo Communications CmA-360 TRMS User manual

INSTRUCTION MANUAL
Read and understand all of the instructions and safety
information in this manual before operating or servicing
this tool.
Register this product at www.TempoCom.com
REV01 © 2020 Tempo Communications Inc. 09/20
CmA-360 TRMS
Milliamp Clamp Meter

2
KEEP THIS MANUAL
Center 265 True RMS Leakage Current Clamp Meter
1
TABLE OF CONTENTS
1. SAFETY INFORMATION .................................................................... 3
2. GENERAL SPECIFICATIONS............................................................... 3
3. ELECTRICAL SPECIFICATIONS .......................................................... 4
3-1AC mA Measurement ....................................................................... 4
3-2AC AMeasurement .......................................................................... 5
3-3AC VMeasurement .......................................................................... 5
3-4DC VMeasurement .......................................................................... 5
3-5CONTINUITY () .................................................................................. 5
3-6RESISTANCE(Ω). ................ .................................................................. 5
4. DESCRIPTION OF THE INSTRUMENT.............................................. 6
4-1Description of the display................................................................. 6
4-2Description of front and rear............................................................ 7
5. BUTTON INSTRUCTION..................................................................... 8
5-1HOLD &LPF Function........................................................................ 8
5-2PEAK HOLD Function ........................................................................ 8
5-3ZERO Function.................................................................................. 8
5-4BACKLIGHT Function ........................................................................ 8
6. MEASURING INSTRUCTION ............................................................. 9
6-1AC A&AC mA Measurement ............................................................ 9
6-2AC VMeasurement ........................................................................ 10
6-3DC VMeasurement ........................................................................ 11
6-4Continuity Measurement ............................................................... 11
6-5Resistance Measurement............................................................... 12
7. BATTERY CHANGING........................................................................12
8. MAINTENANCE..................................................................................13

3
Clamp Meter
2
1. SAFETY INFORMATION
1. Do not operate the tester if there is any sign of damage to the
tester or the test leads.
2. Check the main function dial and make sure it is in the correct
position before each measurement.
3. Do not perform resistance and continuity tests on a live power
system.
4. Do not apply voltage between the test terminals and test
terminal to ground that exceed the maximum limits stated in this
manual.
5. Keep your fingers behind the protection ring on the test probes
when using the test leads.
6. Change the battery when the symbol appears to avoid
incorrect data.
Environmental Conditions
Operation Temperature: 0°C to 40°C (32°F to 104°F); <80 % RH
Storage Temperature: -10°C to 60°C (14°F to 140°F); <80 % RH
Explanation of Symbols
Attention refer to operating instructions.
Dangerous voltage may be present at the terminals.
This instrument is double insulated.
Approvals: EN61010 600V CAT-III
2. GENERAL SPECIFICATION
Digital Display:
4digit liquid crystal (LCD),Maximum reading 6000.
Polarity:
When a negative signal is applied, the “ ”sign appears.
LowBattery Indication:
When the battery voltage is below thatrequired for proper operation
then the symbol will appear on the LCD display.
Sample Rate:
2 times/sec for digital data.

4
Center 265 True RMS Leakage Current Clamp Meter
3
Power Source:
1.5V size AAA battery X 2
Typical battery Life: (without buzzer, backlight)
40 hours at AC mA and ACA and ACV function;
60 hours at DCV and Ohm function. (Alkaline battery)
Auto Power Off:
If there is no key or dial operation for 30 minutes, the meter will power
itself off to save battery life. This function can be disabled by pressing
and holding the “HOLD ”button and powering on the unit.
Overload Indication:
When the applied signal is larger than the maximum for the range in
use the display will show .
Maximum Jaw Opening:
23 mm
Dimensions:
206 x 76 x 33.5 mm
Weight:
262g (with battery)
Accessories:
Carrying case, Batteries, Test Leads & Instruction Manual.
3. ELECTRICAL SPECIFICATION
The accuracy specification is defined as ± ( percentage of reading +
number of counts ) At 23±5°C, ≦80 %RH.
3-1 ACmA (True RMS)
Range Resolution
Accuracy
50~60 Hz
50~500 Hz
6.000 mA
0.001 mA
1.0% + 8 counts
2.0% + 8 counts
60.00 mA
0.01 mA
1.0% + 5 counts 2.0% + 5 counts
600.0 mA
0.1 mA
Zero correction: Fractions smaller than approximately 0.006 mA are
calibrated to zero.
Low Pass Filter
Range Resolution Accuracy
6.000 mA
0.00 1mA
2.0% + 8 counts
60.00 mA
0.01 mA
2.0% + 5 counts
600.0 mA
0.1 mA

5
Clamp Meter
4
3-2 ACA (True RMS)
Range Resolution
Accuracy
50~60 Hz
50~500 Hz
6.000 A
0.001 A
1.0% + 5dgts 2.0% + 5dgts
60.00 A
0.01 A
Low Pass Filter
Range
Resolution
Accuracy
6.000 A
0.001 A
2.0% + 5dgts
60.00 A
0.01 A
3-3 ACV (True RMS)
Range Resolution
Accuracy
50~500 Hz
60.00 V
0.01 V
1.0% + 3dgts
300.V
0.1 V
Input impedance: 2M
3-4 DCV
Range Resolution Accuracy
60.00 V
0.01 V
1.0% + 2dgts
600.0 V
0.1 V
Input impedance: 2M
3-5Continuity
Range
Buzzer Function
Ohm < 45
3-6 Resistance (
)
Range Resolution Accuracy
600.0
0.1
1.0% + 2dgts
6.000 k
0.001 k
60.00 k
0.01 k
600.0 k
0.1 k

6
Center 265 True RMS Leakage Current Clamp Meter
5
4.DESCRIPTION OF THE INSTRUMENT
4-1 Description of the Display
Auto power off indication
Polarity indication
Low battery indication
AC measurement indication
DC measurement indication
Current measurement indication
Voltage measurement indication
ZERO indication
Data hold indication
PEAK hold indication
Low pass filter indication
Continuity test indication
Measurement unit
Resistance measurement indication
Measurement unit

7
Clamp Meter
6
4-2 Description Of Front And Rear
○
1
Current Sensing Clamp
○
2
Safety protection ring
○
3Backlight button
○
4
Clamp opening handle
○
5
Function select dial
○
6
ZERO button
○
7PEAK & / button
○
8
Data hold & LPF button
○
9
LCD display
○
10
COM input terminal
○
11
Positive input terminal
○
12
Battery compartment

8
Center 265 True RMS Leakage Current Clamp Meter
7
5. BUTTON INSTRUCTION
5-1 HOLD & LPF Function
It is possible to freeze the displayed value by pressing on the "HOLD"
button. Press the "HOLD" button again to exit the Hold mode.
To activate the Low Pass Filter (LPF) feature, press and hold the
“LPF” button until the symbol displays. To deactivate the LPF feature,
press and hold the “LPF” button for 2 seconds. The meter will return
to normal mode of operation.
The Cut-Off frequency of the low pass filter is about 160 Hz with
attenuation characteristic of approx. -24 dB/octave.
Note: The LPF function operates on the AC A and AC mA ranges.
5-2 PEAK Hold & / Function Selection
Press "PEAK" button to enter the PEAK mode, the meter records the
peak maximum value. Press the "PEAK " button again, to exit the
peak mode.
When you turn the rotary switch to the Ohms / Continuity Test
position, press the "PEAK" button to select Resistance measurement,
press the "PEAK" button again to select continuity test with buzzer.
5-3 ZERO Function
Press "ZERO" button to enter the Zero mode, ZERO Annunciate will
appear and Zero the display. The reading is stored as reference
value for subsequent measurement.
Press the "ZERO " button again, to exit the zero mode.
5-4 BACKLIGHT Function
When the "" button is pressed, the backlight will be turned on.
Press the button again to turn the backlight off. If the button is not
pressed again then the backlight will be automatically turned off in
about 30 seconds after it is turned on.

9
Clamp Meter
8
6. MEASURING INSTRUCTION
6-1 AC A and AC mA measurement:
1. Set the range selector switch to the desired position. The
current to be measured should be within the selected measuring
range.
2. Normal measurement (see Fig.1):
Press the jaw trigger to open the clampmeter jaws and close them
over one conductor only. The measured current value is shown on the
display. Earth leakage current or any small AC current that flows
through a ground wire can also be measured by this method.
3. Measuring out of balance leakage current (see Fig.2):
Clamp onto all conductors except the ground wire. The measured
imbalance current value is shown on the display.
Before this measurement, disconnect any test leads from the meter
for safety.
In some cases wherein reading the display is difficult, press the HOLD
button and read the result after the clamp is removed from the
conductors.
Fig.1 Normal measurement:
INCORRECT CORRECT

10
Center 265 True RMS Leakage Current Clamp Meter
9
Fig.2 Measuring out of balance leakage current:
3-Phase 3-Wire system Single-Phase 2-Wire system
6-2 AC V Measurement:
:
WARNING!
Maximum Input Voltage is 600V AC/DC. Do not attempt
to Take any voltage measurement that may exceed
this maximum to avoid Electrical shock hazard and/or
damage to this instrument.
Switch the main function selector
to range.
Connect the red test lead to
the "+ ”terminal and the black
lead to the “COM”terminal.
Measure the voltage by touching
the test lead tips to the test circuit
where the voltage measurement is
required.
Read the result from the LCD
display.

11
Clamp Meter
10
6-3 DC V Measurement:
:
Switch the main function
selector to range.
Connect the red test lead to
the “+”terminal and black
lead to the “COM”terminal.
Measure the voltage by
touching the test lead tips to
the test circuit where the
value of voltage is needed.
Read the result from the LCD.
6-4 Continuity Test With Buzzer:
:
Switch the main function to range.
Connect the red test lead to the “+”terminal and the black lead to
the “COM”terminal.
Connect tip of the test leads to the points between which continuity is
to be measured.
If the resistance is under 45Ω, the beeper will sound continuously.
Short circuit Open circuit

12
Center 265 True RMS Leakage Current Clamp Meter
11
6-5 Resistance Measurement
Switch the main function to
range.
Connect the red test lead to the
“+”terminal and the black lead
to the "COM" terminal.
Connect tip of the test leads to the
points where the value of the
resistance is to be measured.
Read the result from the LCD.
Note:
:
When measuring resistance in a
circuit, make sure any power on
the circuit is turned off and any
capacitors are discharged.
7. CHANGING THE BATTERY
When the battery voltage drops below that required for proper
operation of the instrument, the battery symbol will appear on the
LCD display and the battery should be changed.
Before changing the battery, switch the main dial to “OFF ”and
disconnect test leads.
Open the back cover using a screwdriver.
Replace the old batteries with two new 1.5V (AAA Size) batteries.
Close the back cover and tighten the screw before using the meter.

13
Clamp Meter
12
8. MAINTENANCE
WARNING!
Before opening the meter, disconnect both test leads. Never use the
meter unless the battery cover is in place and the screw is tightened.
CAUTION!
To avoid contamination or static damage, do not touch the circuit
board without proper static protection.
8-1 REMARKS:
If the meter is not going to be used for a long time then please
remove the battery and do not store the meter in a high temperature
or high humidity environment.
Keep the cable in the center of the clamp will return a more accurate
test result when making current measurements.
Repairs or servicing not covered in this manual should only be
performed by qualified personnel.
8-2 CLEANING:
Periodically wipe the case with a dry cloth. Do not use abrasives or
solvents on these instruments.
Distributed By :
TRIO Test & Measurement Pty Ltd
T. 1300 853 407
F. 1300 853 409
Sales@triotest.com.au
http://www.triotest.com.au

Tempo Communications
1390 Aspen Way • Vista, CA 92081 • USA
800-642-2155 • FAX: 760-598-9263
Latin America 760-510-0558 • An ISO 9001 Company
Tempo Europe Ltd. • Brecon House, William Brown Close Cwmbran,
NP44 3AB, UK • Tel: +44 1633 927 050
www.TempoCom.com
Table of contents
Other Tempo Communications Measuring Instrument manuals

Tempo Communications
Tempo Communications OPM210 User manual

Tempo Communications
Tempo Communications OFL100 User manual

Tempo Communications
Tempo Communications CableScout CS90B User manual

Tempo Communications
Tempo Communications OFL100 User manual

Tempo Communications
Tempo Communications OPM5 Series Reference guide

Tempo Communications
Tempo Communications OPM510 User manual

Tempo Communications
Tempo Communications 930XC-20C User manual

Tempo Communications
Tempo Communications TV220E User manual

Tempo Communications
Tempo Communications TV220E Reference guide

Tempo Communications
Tempo Communications OFL100 User manual