controller does not display the setting temperature and is not adjustable.The internal pendulum wind stays
unchanged according to the state before switching, but the external pendulum wind is forced to close.
Temperature reduction -
1. Temperature setting: when pressing this key, the setting temperature will be reduced by “32°C, 31 °C, .......,
17°C, 16°C “. (When pressing this key in dehumidification and fan mode, the temperature will not change).
2. Keep pressing will continuously change the temperature.
Temperature addition +
1. Temperature setting: when pressing this key, the setting temperature will be added by “16°C, 17°C, ......., 31°C,
32°C”, (When pressing this key in dehumidification and fan mode, the temperature will not change).
2. Keep pressing will continuously change the temperature.
Up and down swinging (External pendulum wind)
1. Pressing this key in the dehumidification mode, the external pendulum wind is forced to close.
2. Pressing this key in the other modes, the external pendulum switches by “swing, fixed wind, swing” circularly.
Left and right swinging (Internal pendulum wind):
1. Pressing this key in the dehumidification mode, the internal pendulum wind stays unchanged according to the
state before switching.
2. Pressing this key in the other modes, the internal pendulum switches by “swing, stop, swing” circularly.
FAN:
1. When the first power on, the remote controller is set to the automatic wind speed by default. In
dehumidification mode, the wind speed is fixed to low wind and is not adjustable. By pressing the wind speed
key, there is no response to the remote controller.
2. Pressing this key in the other modes, the wind speed switches by “automatic wind speed, low speed, middle
speed, high speed, automatic wind speed “ circularly.pendulum switches by “swing, stop, swing” circularly,
high speed, automatic wind speed “ circularly.
Timer:
1. Under the shutdown state, press this key to set the opening time, range from 1 hour to 24 hour.
2. Under the boot state, press this key to set the shutdown time, range from 1 hour to 24 hour.
3. The timing time is according to the cycle of “1h, 2h, ......., 23h, 24h, cancel, 1h”.
4. Exit timing adjustment after 3 seconds without key pressing.
TURBO:
1. Extension code remote controller has the effect. The remote controller is no TURBO by default, and the
TURBO key will not work in automatic mode, dehumidification mode and fan mode.
2. Pressing this key in the cooling or heating mode, the TURBO mode switches between opening and closing.
When in the TURBO mode, it still displays the wind speed. Switching mode or entering sleep function will
close TURBO mode.
3. If the air conditioner has TURBO mode, pressing this key, the remote controller still displays current
windshield, and indoor unit runs with the highest wind.
ECO:
1. The remote controller is no ECO by default, and the ECO key will not work in automatic mode,
dehumidification mode and fan mode.
2. Pressing this key in the cooling or heating mode, the ECO mode switches between opening and closing.
When in the ECO mode, the setting temperature is set to 26°C (79°F) and other settings are unchanged. If
closing ECO mode, the remote controller will recover to the setting before opening ECO mode. Switching
mode will close ECO mode.
SLEEP:
1. Pressing this key in the modes except of the fan mode, the sleep function switches between opening and
closing. Switching mode will cancel sleep function.
2. When pressing this key, the wind speed is automatically switched to low wind. However, the wind speed can
be adjusted according to the wind speed key (except of the dehumidification mode).
LIGHT
1. When the first power on, there is no lamplight by default. Pressing Fan key 3S force to turn off or turn on the
lamplight. Decide whether to have this function according to the actual model.