TESTO 890 User manual

testo 890 · Thermal imager
Instruction manual

2

1 Contents
3
Pos: 1 /TD/Überschr iften/1. Inhalt @ 0\mod_1177 587817070_79.doc x@ 124 3@ 1 @ 1
1Contents
1Contents...................................................................................................3
2Safety and the environment....................................................................5
2.1. About this document........................................................................5
2.2. Ensure safety...................................................................................6
2.3. Protecting the environment..............................................................7
3Specifications ..........................................................................................8
3.1. Use ..................................................................................................8
3.2. Technical data .................................................................................9
4Product description...............................................................................15
4.1. Overview........................................................................................15
4.1.1. Product components......................................................................................15
4.1.2. Display interface ............................................................................................17
4.1.3. Operating concept .........................................................................................19
4.2. Basic properties.............................................................................20
4.2.1. Power supply .................................................................................................20
4.2.2. File formats and file names............................................................................21
5First steps ..............................................................................................22
5.1. Commissioning ..............................................................................22
5.1.1. Connecting the rechargeable battery .............................................................22
5.1.2. Performing basic settings...............................................................................22
5.1.3. Initial charging of the rechargeable battery ....................................................24
5.2. Getting to know the product...........................................................25
5.2.1. Adjusting the hand strap ................................................................................25
5.2.2. Attaching the lens cover to the hand strap .....................................................26
5.2.3. Rotating the handle........................................................................................27
5.2.4. Attaching a shoulder strap .............................................................................28
5.2.5. Using a lens case ..........................................................................................28
5.2.6. Inserting the memory card .............................................................................29
5.2.7. Fitting/removing IR protection glass...............................................................29
5.2.8. Changing the lens..........................................................................................30
5.2.9. Switching the imager on/off............................................................................31
5.2.10. Manually focusing the image..........................................................................31
5.2.11. Automatically focusing the image...................................................................31
5.2.12. Recording (freezing/saving) an image............................................................32

1 Contents
4
6Using the product .................................................................................33
6.1. Menu bar/tabs............................................................................... 33
6.1.1. Analysis functions tab .......................................................................... 33
6.1.2. Scale and correction functions tab....................................................... 34
6.1.3. Main menu tab..................................................................................... 34
6.2. Menu functions.............................................................................. 36
6.2.1. Measurement................................................................................................. 36
6.2.2. Display options .............................................................................................. 46
6.2.3. Image gallery................................................................................................. 47
6.2.4. Wizards ......................................................................................................... 50
6.2.5. Configuration ................................................................................................. 57
6.2.6. Audio (only testo 890-2)................................................................................. 64
6.3. Measuring ..................................................................................... 66
7Maintaining the product .......................................................................67
8Tips and assistance..............................................................................68
8.1. Questions and answers ................................................................ 68
8.2. Accessories and spare parts......................................................... 69
Pos:2 /TD/--- Seitenwechsel --- @0\mod_117377443060 1_0.docx @ 283 @ @ 1

2 Safety and the environment
5
Pos: 3 /TD/Übersc hriften/2. Sic herheit und Umwelt @ 0\mod_11737 74719351_79.docx @ 292 @ 1 @ 1
2Safety and the environment
Pos: 4 /TD/Übersc hriften/2.1 Zu diese mD okument @ 0\mod_117377525 2351_79.docx @ 346 @ 2 @ 1
2.1. About this document
Pos: 5 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Verwendung/V erwendung (Standar d) @ 0\mod_1173775068554_ 79.docx @ 337 @ 5 @ 1
Use
> Please read this documentation through carefully and
familiarize yourself with the product before putting it to use. Pay
particular attention to the safety instructions and warning advice
in order to prevent injuries and damage to the products.
> Keep this document to hand so that you can refer to it when
necessary.
> Hand this documentation on to any subsequent users of the
product.
Pos: 6 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventionen/ Tabellenkopf W arnhinweise @ 2\mod_120764 5198296_79.docx @ 14334 @ 5 @ 1
Warnings
Always pay attention to information that is marked by the following
warnings with warning pictograms. Implement the specified
precautionary measures.
Representation Explanation
Pos: 7 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventionen/W arnhinweis VORSIC HT@ 2\ mod_1207651416515_79. docx @ 14416 @ @ 1
CAUTION indicates potential minor injuries
Pos: 8 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventionen/W arnhinweis ACHTUNG (Pr oduktschaden) @ 2\mod_1 207651536812_79. docx @ 14434 @ @ 1
NOTICE indicates circumstances that may lead to
damage to the products
Pos: 9 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventionen/ Tabellenkopf Sy mbole und Schreibkonv. @ 2\mod_120 7652481703_79.doc x @ 14452 @ 5 @ 1
Symbols and writing standards
Represen-
tation Explanation
Pos: 10 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventione n/Symbole und Schreibkon v. [Standard_klein] @ 2\mod_12076526 32140_79.docx @ 14470 @ @ 1
Note: Basic or further information.
1. ...
2. ...
Action: more steps, the sequence must be followed.
> ... Action: a step or an optional step.
- ... Result of an action.
Pos: 11 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventione n/Schreibkonv. Menü @ 2\ mod_1207655303453_79. docx @ 14488 @ @ 1
Menu Elements of the instrument, the instrument displays
or the program interface.

2 Safety and the environment
6
Pos: 12 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventione n/Schreibkonv. [OK] @ 2\mod_12076554 89218_79.doc x@ 14506 @ @ 1
[OK] Control keys of the instrument or buttons of the
program interface.
Pos: 13 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventione n/Schreibkonv. Funk tionen/Pfade (.. .|...) @ 2\mod_1207655781 390_79.docx @ 14524 @ @ 1
... | ... Functions/paths within a menu.
Pos: 14 /TD/Sic herheit und Umwelt/Zu diese m Dokument/Symbole und Sc hreibkonventione n/Schreibkonv. Beispi elangaben ("...") @ 2\mod_1207656016281_ 79.docx @ 14542 @ @ 1
“...” Example entries
Pos: 15 /TD/Übersc hriften/2.2 Sic herheit gewährleisten @ 0\ mod_1173780783960_79. docx @ 366 @ 2 @ 1
2.2. Ensure safety
Pos: 16 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/Produkt bestimmungs gemäß verwenden @ 0\mod_1173 781261848_79.doc x @ 386 @ @ 1
> Only operate the product properly, for its intended purpose and
within the parameters specified in the technical data. Do not
use any force.
Pos: 17 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/Gerät bei Beschädigu ngen nicht in Betrieb neh men@ 0\ mod_118698594537 5_79.docx @ 2252 @ @ 1
> Do not operate the instrument if there are signs of damage at
the housing, mains unit or feed lines.
Pos: 18 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/testo 885/Detektor @ 9\mod_13112514 07168_79.docx @ 85589 @ @ 1
During operation, the imager must not be pointed at the sun or
other intensive sources of radiation (e.g. objects with temperatures
greater than 550°C/1022°F, if using the high-temperature
measurement range 1400°C/2552°F). This can lead to serious
damage to the detector. The manufacturer assumes no liability for
any such damage to the microbolometer detector.
Pos: 19 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/vor Ort gültige Sic herheitsbestimmungen be achten @ 0\mod_11869971 07328_79.docx @ 2298 @ @ 1
> The objects to be measured or the measurement environment
may also pose risks: Note the safety regulations valid in your
area when performing the measurements.
Pos: 20 /TD/Sic herheit und Umwelt/Si cherheit gewährlei sten/Nicht mit Lö sungsmitteln la gern @ 0\mod_11756923751 79_79.docx @ 583 @ @ 1
> Do not store the product together with solvents. Do not use any
desiccants.
Pos: 21 /TD/Sic herheit und Umwelt/Sicher heit gewährleiste n/Nur beschriebene W artungsarbeiten durc hführen @ 0\mod_117569270519 5_79.docx @ 601 @ @ 1
> Carry out only the maintenance and repair work on this
instrument that is described in the documentation. Follow the
prescribed steps exactly. Use only original spare parts from
Testo.
Pos: 22 /TD/Sic herheit und Umwelt/Si cherheit gewähr leisten/Akku-Sic herheitshinweise ( LiIon) @ 0\mod_11 87184666109_79.doc x @ 2363 @ @ 1
> Improper use of rechargeable batteries can lead to destruction
or injuries by means of current surges, fire or escaping
chemicals. The following instructions must be observed to avoid
such hazards:
• Only use in accordance with the directions in the instruction
manual.
• Do not short, take apart or modify.
• Do not expose to heavy impacts, water, fire or temperatures
above 60 °C.
• Do not store in the proximity of metal objects.
• Do not use leaky or damaged rechargeable batteries. In the
event of contact with battery acid: Thoroughly wash affected
area with water and consult a doctor, if necessary.

2 Safety and the environment
7
• Only charge in the instrument or the recommended charging
station.
• Immediately stop the charging process if this is not
completed in the given time.
• In the event of improper function or signs of overheating,
immediately remove the rechargeable battery from the
measuring instrument/charging station. Caution:
Rechargeable battery may be hot!
Pos: 23 /TD/Übersc hriften/2.3 Umwel tsc hützen @ 0\mod_117378084 3645_79.docx @ 375 @ 2 @ 1
2.3. Protecting the environment
Pos: 24.1 /TD/Sic herheit und Umwelt/U mwelt schützen/Akkus/ Batterien entsorgen @ 0\mod_117569 3637007_79.docx @ 619 @ @ 1
> Dispose of faulty rechargeable batteries/spent batteries in
accordance with the valid legal specifications.
Pos: 24.2 /TD/Si cherheit und Umwe lt/Umwelt schützen/ Produkt entsorgen @ 0\mod_1173780 307072_79.doc x@ 357 @ @ 1
> At the end of its useful life, send the product to the separate
collection for electric and electronic devices (observe local
regulations) or return the product to Testo for disposal.
Pos:25 /TD/--- Seitenwechsel--- @ 0\mod_1173774430601_0. docx @ 283 @ @ 1

3 Specifications
8
Pos: 26 /TD/Übersc hriften/3. Leistu ngsbeschreibung @ 0\mod_1 173774791554_79.d ocx @ 301 @ 1 @ 1
3Specifications
Pos: 27 /TD/Übersc hriften/3.1 Verwendun g @ 0\mod_11762110164 37_79.docx @ 695 @ 2 @ 1
3.1. Use
Pos: 28 /TD/Leis tungsbeschreibung/V erwendung/testo 8 xx/testo 890 @ 10\mod_131850 9586449_79.doc x@ 96046 @ 5 @ 1
The testo 890 is a handy and robust thermal imager. It enables you
to carry out contactless determination and display of the
temperature distribution on surfaces.
Typical areas of application are:
• Building inspection: energetic assessment of buildings, and
inspection of heating, ventilation and air conditioning systems.
• Preventative maintenance (servicing): mechanical and electrical
inspection of systems, machines and energy distribution
systems
• Production monitoring (quality assurance): monitoring of
production processes
• Professional energy consultation, leak detection
• Checking of photovoltaic modules
The testo 890 is available in several versions, which are tailored to
various usage requirements:
• testo 890-1: high-quality wide angle lens 42° x 32°, detector 640
x 480/ 1280 X 960 pixels*, NETD < 40 mK at 30°C, 2GB SD card
for approx. 800 to 1000 images, minimum focusing distance 0.1 m,
touchscreen, built-in digital imager with power LEDs for illumination,
auto-focus, isotherm, min/max/avg on area, image stitching wizard,
laser (not available in all countries), rotatable handle, rotatable and
pivoting display
• testo 890-2, additional/different functions/features: telephoto
lens (optional), display of the surface moisture distribution
through manual entry of the environmental conditions (optional:
humidity measurement in real time with radio humidity probe),
site recognition with image management, voice recording, high
temperature measurement (optional), Full radiometric video
measurement (optional)
Export control
Thermal imagers may be subject to the export restrictions of the
European Union.
Please observe the national regulations for export control when
exporting.
* With SuperResolution, get four times more measurement values for
even more detailed analysis of thermal images.

3 Specifications
9
Pos: 29 /TD/Übersc hriften/3.2 Techni sche Daten @ 0\mod_11762110 88437_79.docx @ 704 @ 2 @ 1
3.2. Technical data
Pos: 30 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/890 Bi ldleistung Infrar ot@ 10\mod_13185 10092008_79.docx @ 96079 @ 5 @ 1
Infrared image output
Feature Values
Detector type FPA 640 x 480 pixels/ 1280 X 960 pixels*, a.Si
Thermal sensitivity
(NETD)
< 40 mK at 30°C (86°F)
Field of vision/min.
focusing distance
42° x 32°/0.1 m (0.33 ft)
Telephoto lens (optional): 15° x 11°/0.5 m
(1.64 ft)
Geometric resolution
(IFOV)
1.13 mrad (standard lens)
0.42 mrad (telephoto lens)
Super-resolution
(pixels/IFOV) -
optional
1280 x 960 pixels
0.71 mrad (standard lens)
0.26 mrad (telephoto lens)
Image refresh rate 33 Hz within EU, 9 Hz outside of EU
Focus Automatic/manual
Spectral range 8 - 14 μm
Pos: 31 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885, 890 Bildleis tung Visuell @ 9\mod_13045 11457978_79.doc x@ 79703 @ 5 @ 1
Visual image output
Feature Values
Image size 3.1 megapixels
Min. focusing
distance
0.5 m (1.64 ft.)
Pos: 32 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885, 890 Bilddarste llung @ 9\mod_13045116698 52_79.docx @ 79736 @ 5 @ 1

3 Specifications
10
Image presentation
Feature Values
Image display LCD touchscreen, 10.9 cm (4.3") screen
diagonal, with 640 X 480 pixels
Digital zoom 1- to 3-fold
Display options IR image/real image
Video output USB 2.0
Video stream Max. 25 Hz within EU, max. 9 Hz outside EU
Colour palettes 9
Pos: 33 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/890 Messu ng @ 10\mod_131851059 2552_79.docx @ 96112 @ 5 @ 1
Measurement
Feature Values
Temperature ranges
(can be changed)
-20 to 100°C (-4 to 212°F)
0 to 350°C (32 to 662°F)
Only testo 890-2, optional:
350 to 1200°C (662 to 2192°F)
Accuracy ±2°C (±3.6°F) or ±2% of meas. val. (higher
value applies)
Reproducibility ±1°C (±1.8°F) or ±1% (higher value applies)
Emissivity/reflected
temperature settings
0.01 to 1.00
Reflected
temperature/transmis
sion correction
(atmosphere)
settings
Manual
Minimum measuring
point diameter
Standard lens: 3.4 mm at 1 m distance
Telephoto lens: 1.3 mm at 1 m distance
Pos: 34 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885, 890 Messungfunk tionen @ 9\mod_1311931466 014_79.docx @ 86843 @ 5 @ 1

3 Specifications
11
Measurement
Feature Values
Display of surface
moisture distribution
Only testo 890-2:
via manual input
Humidity
measurement with
radio humidity probe
(not available in all
countries)
Only testo 890-2, optional:
automatic measurement value transfer in
real time
Solar mode Yes
Analysis functions Up to 3 measuring points, hot/coldspot
detection, area measurement
(min-/max-/average value), isotherm, alarms
Pos: 35 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/890 Ka meraausstattung @ 10\mo d_1318510924659_79.doc x @ 96145 @ 5 @ 1
Imager equipment
Feature Values
Digital imager Yes
Standard lens 42° x 32°
Telephoto lens Optional: 15° x 11°
Site recognition with
image management
Only testo 890-2
Image stitching
wizard
Yes
Laser (not available
in USA, Japan,
China)
635 nm, Class 2
Voice recording Only testo 890-2: via Bluetooth (not
available in all countries)/via wired headset
Video measurement
(via USB)
Up to 3 measuring points
Full radiometric video
measurement (via
USB)
Only testo 890-2 (optional)

3 Specifications
12
Pos: 36 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885/ 890 Bildspeicherung @ 10\ mod_1318511087158_7 9.docx @ 96178 @ 5 @ 1
Image storage
Feature Values
File format .bmt, possible export to .bmp, .jpg, .png,
.csv, .xls
Video file format (via
USB)
.wmv, .mpeg-1 / only testo 890-2: vmt (full
radiometric video, testo format)
Storage device SD card 2 GB (800 to 1000 images)
Pos: 37 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885, 890 Stromversor gung @ 9\mod_1311933267368 _79.docx @ 86876 @ 5 @ 1
Power supply
Feature Values
Battery type Fast-charging Li-ion battery can be changed
on site
Operating time Approx. 4.5 h at 20 to 30°C (68 to 86°F)
Charging option In instrument/in charging station (optional)
Mains operation Yes, with mains unit 0554 8808
Mains unit output
voltage
5 V / 4 A
Pos: 38 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885, 890 Umgebungsbedi ngungen @ 9\mod_13119334 55412_79.doc x@ 86909 @ 5 @ 1
Ambient conditions
Feature Values
Operating
temperature range
-15 to 50°C (5 to 122°F)
Storage temperature
range
-30 to 60°C (-22 to 140°F)
Air humidity 20 to 90% non-condensing

3 Specifications
13
Pos: 39 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/890 Phy sikalische Kenndaten @ 10\ mod_1318511291766_ 79.docx @ 96211 @ 5 @ 1
Physical features
Feature Values
Weight 1630 g (including battery)
Dimensions (L x W x
H)
253 x 132 x 111 mm (0.83 x 0.44 x 0.37")
Tripod mounting 1/4" - 20 UNC
Housing protection
class (IEC 60529)
IP54
Vibration
(IEC 60068-2-6)
2G
Pos: 40 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/885, 890 Bluetooth @ 9\ mod_1313750881112_79. docx @ 92635 @ 5 @ 1
Bluetooth (not available in all countries)
Feature Values
Type designation BlueGiga WT 11
Product note WT 11
Identification B01867
Company 10274
Information of the
FCC (Federal
Communications
Commission)
This device fulfils part 15 of the FCC
guidelines. Commissioning is subject to the
two following conditions: (1) This instrument
must not generate any dangerous
interference and (2) this instrument must be
able to receive interference, even if this
could have undesired effects on operation.
Changes and modifications to the
instrument that have not been expressly
approved by testo AG may nullify the user's
right to use the instrument.
Operating
information
You can switch off Bluetooth at any time if
you wish to save battery power or if the use
of radio links is not permitted, e.g. in aircraft
or hospitals.
Pos: 41 /TD/Leis tungsbeschreibung/ Technische Daten/W BKs/testo 885, 890/Ric htlinien, Garantie @ 9\ mod_1311933890294_79. docx @ 86942 @ 5 @ 1

3 Specifications
14
Guidelines, warranty
Feature Values
EU Directive 2004/108/EC
Warranty 2 years, warranty conditions: see
www.testo.com/warranty
Pos:42 /TD/--- Seitenwechsel--- @ 0\mod_1173774430601_0. docx @ 283 @ @ 1

4 Product description
15
Pos: 43 /TD/Übersc hriften/4. Produkt beschreibung @ 0\mod_1 173774846679_79.doc x@ 310 @ 1 @ 1
4Product description
Pos: 44 /TD/Übersc hriften/4.1 Übersi cht @ 0\mod_11763799460 03_79.docx @ 733 @ 2 @ 1
4.1. Overview
Pos: 45 /TD/Produk tbeschreibung/ Übersicht/testo 8xxte sto 885, 890 @ 9\mod_130451 5275913_79.docx @ 79934 @ 33 @ 1
4.1.1. Product components
1Digital imager lens for taking visual images and two
power -LEDs for illuminating the image.
2Infrared imager lens for taking thermograms.
3[Release lens] for releasing the lens lock.
4Thread (1/4" - 20 UNC) for attaching a tripod (bottom of
imager). Do not use desktop tripods: danger of tipping over!
5Laser (not available in all countries) for marking the
measurement object.
CAUTION
Laser radiation! Class 2 laser
> Do not look into the beam.
6Focusing ring for adjusting the focus manually.
CAUTION
Auto mechanism may be damaged!
> Only turn focusing ring when auto-focus is deactivated ( ).

4 Product description
16
7Rotatable handle with adjustable hand strap and fastening loop
for the lens cover.
8Battery compartment (bottom of imager).
9Operating buttons (back and top of imager):
Button Functions
[] Switch imager on/off
[●] (5-way
joystick) Press [●]: open menu, activate selection/setting.
Move [●]up/down/right/left: select functions,
navigate
[Esc] Cancel action.
[A], [B] Shortcut keys for activating various functions. The
current shortcut key assignment is displayed (top
left). For adjustable functions, see Configure key,
page 61.
[Trigger
button]
(round
unmarked
button)
Press button (only when auto-focus is activated):
focus image automatically.
Press button: record image (freeze/save).
10 Two fixing eyelets for carrying/shoulder strap.
11 Interface terminals:
Terminal Assignment
Top Mains socket, headset socket, Battery status LED.
Battery status LED indications (imager on):
• Off (no battery inserted).
• Flashing (mains unit is connected and battery is
charging).
• On (mains unit is connected and battery is fully
charged).
Bottom USB port, memory card slot.
12 Display, can be flipped out 90° and rotated 270°.
When the imager is switched on, the display remains active
even when folded in. It is advisable to use the power-save
options to prolong the battery life, see Power-save options,
page 62.

4 Product description
17
4.1.2. Display interface
1Image display: shows IR image or real image.
2Scale display:
Display Description
Protection glass function activated. No symbol
when function is deactivated.
, or Selected unit for measurement value and scale
displays.
Left: temperature margin of the image displayed,
showing the minimum/maximum measurement
value (with automatic scale adjustment) or the
selected minimum/maximum display value (with
manual scale adjustment).
Right: temperature margin of the image displayed,
based on the set measurement range, showing
the measurement range limits.
or Automatic or manual scale adjustment activated.
Histogram adjustment activated.
Set emissivity.

4 Product description
18
3 Imager mode selection bar:
button for recording mode, button for image gallery
mode.
4Menu bar: the menu bar comprises 3 tabs including buttons for
selecting functions:
Further information is available under Menu bar/tabs, page 33.
5Status displays:
Display Description
, Possible shortcut key functions (to change the
assignment, see Configure key, page 61):
: Image type.
: Emissivity.
: Palette.
: Scale.
: Power -LEDs.
: Laser.
CAUTION
Laser radiation! Class 2 laser
> Do not look into the beam.
: Adjustment.
: Zoom in.
: Zoom out.
: Humidity
: Solar
: Image stitching
: Site recognition
When viewing a saved image in the single image
view of the image gallery, the function buttons are

4 Product description
19
Display Description
permanently assigned the following functions:
: display previous image.
: display next image.
, Power supply/battery capacity:
: Mains operation, battery fully charged.
: Mains operation, no battery inserted.
: Battery operation, capacity 75-100%
: Battery operation, capacity 50-75%
: Battery operation, capacity 25-50%
: Battery operation, capacity 10-25%
: Battery operation, capacity 0-10%.
- - - - (animated): battery is
charging.
or Auto-focus activated or deactivated.
Only testo 890-2: radio link to radio probe
established.
Only testo 890-2: Bluetooth interface activated.
Only testo 890-2: headset connected.
USB connection established.
Pos: 46 /TD/Produk tbeschreibung/ Grundlegende Eigenschaf ten/WBKs/testo 885/ Bedienkonzept Touch/ Joystick @ 9\mod_13052723 41960_79.doc x@ 80234 @ 3555 @ 1
4.1.3. Operating concept
The imager can be operated in two different ways.
Operation via touchscreen offers quick access to functions.
Operation via joystick requires more actions but enables single-
handed operation of the imager.
Joystick operation
Selection and activation is carried out in two steps: moving the
joystick ( [●] ) up/down/right/left moves the orange selection box on
the display. The selected function or button is activated by pressing
the joystick.

4 Product description
20
Touchscreen operation
Selection and activation is carried out in one step: the required
function or button is selected at the touch of a fingertip and is
activated at the same time.
Capacitive touchscreen. Operation is only possible with a
bare fingertip (no gloves) or a conductive stylus pen.
Illustration in this document
To carry out the basic settings, examples of both methods of
operation are given, describing all steps, see Performing basic
settings, page 22.
The other chapters only deal with functions/buttons that have to be
activated:
• Touchscreen operation: touch with a fingertip.
• Joystick operation: select first (move joystick up/down/right/left),
then activate (press joystick).
Pos: 47 /TD/Übersc hriften/4.2 Grundle gende Eigenschaften @ 0\ mod_1176380399692_79. docx @ 742 @ 2 @ 1
4.2. Basic properties
Pos: 48 /TD/Produk tbeschreibung/ Grundlegende Eigenschaf ten/WBKs/testo 885/ 885, 890: Stromversor ung @ 9\mod_1311257940269 _79.docx @ 85662 @ 3 @ 1
4.2.1. Power supply
The power is supplied to the instrument via a replaceable
rechargeable battery or via the mains unit provided.
With an attached mains unit, power is supplied automatically via
the mains unit and the instrument's rechargeable battery is charged
(only at ambient temperatures from 0 to 40°C).
Under high ambient temperatures a longer charging time
may be required.
Charging the battery is also possible using a desktop charging
station (accessory: 0554 8851).
The instrument is equipped with a buffer battery to maintain the
system data during an interruption in the power supply (e.g. when
the battery is changed).
Pos: 49 /TD/Produk tbeschreibung/ Grundlegende Eigenschaf ten/WBKs/testo 885/ 885, 890: Dateiforma teund D ateinamen @ 9\mod_131 1258646347_79.doc x@ 8569 5 @ 3 @ 4
Other manuals for 890
2
Table of contents
Other TESTO Thermal Camera manuals