THERA-Trainer THERA-VITAL Owner's manual

Art. Nr.: A00x-xxx_Rev 01
Letzte Bearbeitung: KW16/2015
APPENDIX THERA-VITAL
USER MANUAL
Appendix to english translation of original user manual
0297

THERA-VITAL
APPENDIX USER MANUAL
2 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Amendment to chapter 4 „Safety“
Observe the user manual.
Use THERA-vital exclusively in good and functional condition.
Regularly check tightness of screws.
Prior to the initial start-up, have your trained dealer, doctor or therapist show
you how to use the product.
Before starting the training, consult a doctor or therapist and clarify whether
THERA-vital can be used without assistance.
Prior to the initial start-up, have your trained dealer, doctor or therapist ins-
truct the assistant.
Put THERA-vital and chair/wheelchair on even and slip-proof floor.
Make sure that adjustable device base is locked.
Use THERA-vital exclusively when sitting.
Always wear closed shoes without laces when training.
Always wear close-fitting clothes when training.
Remove any jewelry and accessories before starting the training session.
Make sure that the self-operatedtip-up protection is safely fastened to the
wheelchair.
Do not use safety handle or upper body exerciser as standing aid.
Do not use THERA-vital in wet, humid or hot environment.
Have exclusively trained dealers do any repair work.
In case of damage, malfunctions, etc. of the THERA-vital, contact a trained
dealer immediately.
Consult the manufacturer before any modificationand modify THERA-vital
exclusively with the manufacturer's approval.
Do not smoke while exercising.
Make sure that THERA-vital does not get wet.
If any symptoms of illness occur during or after training, seek medical advice
immediately.
Always supervise children during training.
When laying cables, make sure that
–the user's movements are not limited.
–the movements of the THERA-vital are not limited.
–there is no risk of persons falling over or being limited by cables.
Position THERA-vital so that power plug is easily accessible and can be
pulled out of socket outlet quickly in case of emergency.
Use the manufacturer'soriginal parts exclusively.
Use THERA-vital exclusively with undamaged and functional cables.
Make sure to run power supply cable in such a way that there is no risk of
strangulation.
Take care not to pinch any fingers when adjusting settings on THERA-vital.
Use THERA-vital exclusively with correctly set supply voltage.
Before opening the housing, make sure that power plug is unplugged.
If the user has a cardiac pacemaker, consult a doctor before the first training
session.
Make sure that cardiac pacemaker is working reliably when using the cardio-
pulse-set.
Exercise exclusivelyif THERA-vital is switched on.
Pull power plug after every training session.
Before every training, make sure that safety equipment is working correctly.
Keep animals and playing children away from THERA-vital.

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 3
Last update: CW16/2015
Leave THERA-vital at room temperature for 1 hour before using it for the first
time.
Transport THERA-vital exclusivelywith transport castors on even and stable
floors.
For safe use of the THERA-vital, use self-operated tip-up protection.
In the case of paralysis, spasms or weak legs, use THERA-vital exclusively
with the leg support option.
Do not touch moving parts (e.g. crank, radius adjustment, foot rests, etc.).
Make sure that power plug is disconnected before adjusting any settings on
movable parts.
In the case of contractures or limited joint mobility, use foot rests with step-
less radius adjustment.
Make sure that power plug is disconnected before adjusting any settings on
foot rests with stepless radius adjustment.
Make sure that arm rests are safely attachedto therapy grips or cranks when
exercising the upper body.
Exercise exclusively with two therapy grips or two arm rests.
Exercise exclusively with bothfeet correctly positioned in the foot rests.
When training in an electric wheelchair, switch off electronic control/driving
function.
Limit motor power as required for the user and his training state.
Set sensitivity of spasm detection to fit the user's needs.
Make sure that the user exercises with a stable chair that will not wobble or
tip over.
Before every training session using a chair with castors, make sure that
–it is possible to lock the castors.
–inadvertent unlocking of the castors while exercising is not possible.
Make sure that it is not possible for the chair/wheelchair to tip over.
Before starting the upper body training, pull out device base at least 10 cm.
Use USB-interface exclusively with options (USB stick, printer) approved by
the manufacturer. End training session before connecting.
For ports with symbol: Damage due to static charging:
–Do not touch with hands or tools.
–Discharge potential static electricity, e.g. touch device frame with metal
part.
Use exclusively power plug supplied by the manufacturer.
Make sure that children do not swallow or inhale any small parts (e.g. covers
of USB-interfaces,Bluetooth sticks, retaining screws).

THERA-VITAL
APPENDIX USER MANUAL
2 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Amendment to chapter 7.17 „THERA-vital: Control pad
with colour screen“
Control and display unit with 5.7" colour screen
(1) Buttons Number of revolutions
(2) Button Direction of rotation
(3) Button Easy entry
(4) START button
(5) STOP button
(6) Switch button Leg/upper body exerciser
(7) Button Anti-spasm-control
(8) Buttons Exercising resistance
4 Art. no.: A004-791_Rev 01
Last update: CW16/2015

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 5
Last update: CW16/2015
Control and display unit with 10.4" colour screen incl. touch function
(1) Buttons Number of revolutions
(2) Button Direction of rotation
(3) Button Easy entry
(4) START button
(5) STOP button
(6) Switch button Leg/upper body exerciser
(7) Button Anti-spasm-control
(8) Buttons Exercising resistance
(9) Button Switch training program
The control and display unit with 10.4" colour screen incl. touch function uses
touchscreen fields; the control and display unit with 5.7'' colour screen uses
but- tons.
The operation of control and display units with 5.7'' colour screen is identical to
units with 10.4'' colour screen.
Functions of control and display units
Press button:THERA-vital starts trainingsession with basic settings.
–THERA-vital starts at 10 rpm.
Press button after interruption (break): Training session is resumed.
Press button: THERA-vital interrupts current training session (break).
Press button twice:THERA-vital stops current training session.
–After at least 1 minute of exercise, control and display unit shows report
of the training session.
Note
START-Taste
STOP-Taste

THERA-VITAL
APPENDIX USER MANUAL
6 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Button easy
entry Makes it easier to get into the THERA-vital.
Button highlighted in red indicates that easy entry function is activated.
Press button: Crank moves into first entry position.
–First foot rest is down
.
Put first foot into foot rest.
Press button again: Crank moves into second entry position.
–Second foot rest is down.
Put second foot into foot rest.
Secure first foot with velcro or foot fixing/leg support.
Press button again: Crank moves into first entry position.
Secure second foot with velcro or foot fixing/leg support.
Press START button: Easy entry function is finished.
Button Number Press button +: THERA-vital increases number of revolutions step by step.
of revolutions Press button -: THERA-vital reduces number of revolutions step by step.
Press and hold button: Increase or reduce number of revolutions continuo-
usly until maximum or minimum is reached.
THERA-vital starts at 10 rpm.
Maximum number of passive revolutions: 60 rpm.
Button
Direction of
rotation
Press button: THERA-vital changes direction. THERA-vital slows down to 0
rpm and resumes movement in opposite direction with pre-set number of
rotations.
Black arrow shows current direction of rotation.
Switch button
Leg/upper body
exerciser
Press STOP button twice: THERA-vital stops current training session.
Press switch button: THERA-vital switches from leg to upper body exerciser or
the other way round.
–Symbol Foot lights up: Leg exerciser active.
–Symbol Hand lights up: Upper body exerciser active.
The switch button is inactive during training sessions or if no upper body
exerciser is installed.
Leg and arm exercise is not possible at the same time.
Button Anti-
spasm-control
Button Exercis-
ing resistance
Press button: THERA-vital deactivates anti-spasm-control.
–Symbol Lightning is inactive (grey lightning).
Pressbuttonagain:THERA-vitalactivatesanti-spasmcontrol.
–Symbol Lightning is active (red lightning).
Press button +: THERA-vital increases exercising resistance step by step.
Press button -: THERA-vital reduces exercising resistance step by step.
Press and hold button: Increase or reduce training resistance continuously
until maximum or minimum is reached.
Current exercising resistance is adjustable in 15 steps.
Maximum exercising resistance:
–leg exerciser: 22 Nm
–upper body exerciser: 8 Nm
Exercisingresistancesetting will remain constant within the entire rpm range.
Higher pedaling frequency = higher performance.

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 7
Last update: CW16/2015
Shows current training program before the training session starts.
Press button +/- : Allows changing the training pro-
gram before beginning the session when using a 10.4'' colour screen.
–Button will be inactive during training session.
Button Switch
training
program
Button Switch training program is exclusivelyavailable with the control and display
unit with 10.4'' colour screen.
For controland display unit with 5.7'' colour screen, switch trainingprogramvia sub
menu.
Press button combination STOP button + button : THERA-vital
switches to sub menu.
Activate sub menu button for quick access in sub menu Basic settings/Confi-
guration.
Switching to sub menu isexclusively possible before the training session has
begun.
Press button combination STOP button + button : THERA-vital
activates button lock.
–It is still possible to adjust settings for 30 seconds after activating the but-
ton lock.
–
Status bar indicates active button lock by displaying a padlock
symbol
.
Activate button lock before starting the training session.
Press button combination STOP button + button again:
THERA-vital deactivates button lock.
Setting the training time is exclusively possible during a training session.
Press button : THERA-vital increases training time by minutes.
Press button : THERA-vital reduces training time by minutes.
Press and hold buttons: Increase or reduce training time continuously until
maximum or minimum is reached.
START/STOPbuttons are always active.
The sub menu enables the setting of further parameters.
Note
Sub menu
Button lock
Changing
training time
Note

THERA-VITAL
APPENDIX USER MANUAL
8 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Display units 1
2
3
4
5
6
7
14 13 12 11 10 9 8
Note Display before training session has started
2 4
3
5 6
15
Note Display during training session
(1) Display Training program
(2) Display Heart rate limit setting
(3) Pulse indicator
(4) Power display
(5) Covered distance
(6) Remaining training time
(7) Status bar
(8) Printer
(9) Icon Group therapy offline
(10) Icon Group therapy online
(11) Bluetooth
(12) Button lock on
(13) Microphone off
(14) Speakers off
(15) Display Biofeedback
Note The operationof controland display elementswith 5.7'' colour screenis identical
to units with 10.4'' colour screen.

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 9
Last update: CW16/2015
Explanation of display unit
Shows e.g. button lock, voice-controlled emergency stop, printer connection
for training data, microphone sensitivity.
Hidden during training sessions.
Indicates active training program on home screen.
It is not possible to change training programs during training sessions.
Hidden during active training sessions.
The heart symbol shows the heart rate limit setting.
Exclusively in combination with control and display unit with cardio-pulse-
set.
Indicates the user's current pulse rate.
Reduces exercising resistance as soon as the set pulse rate is reached.
The user's pulse rate during the training session always stays below the limit
set by the doctor.
Indicates performance in Watt.
Exclusively for active muscular exercise.
Indicates entire covered distance in km.
Indicates remaining training time.
Group therapy online (green): Connection between THERA-vital and Mini-
PC.
Group therapy offline (red): No connection between THERA-vital and Mini-
PC.
When symbol Group therapy offline appears:
Verify that
–training program Group therapy is selected.
–Mini-PC is switched on.
–software Cycling group therapy is open and started on Mini-PC.
–Mini-PC is within range of Bluetooth connection (about 10 m).
–Bluetooth stick is correctly connected.
–Mini-PC is correctly connected to mains.
–external server is selected in sub menu Configuration.
If no connection is established after the possible causes listed above have been
checked and ruled out:
Select a different training program and return to training program Group
therapy from there.
Indicates that the option Printer for Training Documentation for printing the
training report is available.
Indicates a Bluetooth connection.
Indicates that the microphone is deactivated.
Indicates that the button lock is activated.
Indicates that the speakers are deactivated.
Status bar
Display
Training program
Display Heart
rate limit setting
Pulse indicator
Power display
Covered dis-
tance
Remaining
training time
Icon Group
therapy
online/offline
Printer
Bluetooth
Microphone off
Button lock on
Speakers off

THERA-VITAL
APPENDIX USER MANUAL
10 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Display Biofeed-
back Shows biofeedback Symmetry bar or Symmetry road as factory setting.
It is still possible to adjust settings for 30 sec. It is possible to set further
biofeedback illustrations in the sub menu.
Use START button to change between Symmetrybar and Symmetryroad.

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 11
Last update: CW16/2015
Amendment to chapter 8 „Submenu (THERA-vital only,
for experienced users)“
The software of the control and display unit with 5.7'' or 10.4'' colour screen has a
sub menu that permits setting several parameters to adapt the THERA-vital to the
user's individual needs.
Calling up the sub menu
Press STOP button and button at the same time.
Software switches to sub menu.
Activate sub menu button for quick access in sub menu Basic settings/
Configuration :
Navigation of sub menu
Sections of sub menu:
Neuro
Ortho
Cardio
Isokinetic
Keeper
Hedgehog
Car
Planet
Group therapy
Basis settings
1. Current section of sub menu
2. Current selection
3. Down/reduce
Move down in direction of arrow.
Inmenu items where a value is entered (e.g. motor power), the value entered
will reduce.
4. Saving/confirmingchanges
Save settings.
In menu items with sub-items, go to next menu item.
5. Cancel/reject changes
Go one level up.
6. Up/increase
Move up in direction of arrow.
Inmenu items where a value is entered (e.g. motor power), the value entered
will increase.

THERA-VITAL
APPENDIX USER MANUAL
12 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Menu structure Control and display unit with 5.7" colour screen
1st level
2nd level
Adjustable values, func-
tions
Factory settings
Neuro
Training time
1-180 min.
15 min.
Direction of rotation auto-
matic
on/off
off
Biofeedback
Symmetry bar
Symmetry road
passive
off
Symmetry bar
(smiley for upper
body training)
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Spasm program
forward
backward
alternating
follow
forward
Autom. speed
adaptation
on/off
off
Heart rate limit
60-150/min
100/min
Ortho
Training time
1-180 min.
15 min.
Biofeedback
(inactive for upper body
training)
Symmetrybar
Symmetry road
passive
off
Symmetry bar
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Muscle support
on/off
on
Heart rate limit
60-150/min
100/min
Cardio
Training time
1-180 min.
15 min.
Biofeedback
(inactive for upper body
training)
Symmetry bar
Symmetry road
passive
off
Symmetrybar
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Heart rate limit
60-150/min
100/min

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 13
Last update: CW16/2015
1st level
2nd level
Adjustable values, func-
tions
Factory settings
Isokinetic
Training time
1-180 min.
15 min.
Biofeedback
Symmetry bar
Symmetry road
passive
off
Symmetrybar
(smiley for upper
body training)
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Spasm program
forward
backward
alternating
follow
forward
Heart rate limit
60-150/min
100/min
Basic set-
tings
Volume
0 (off)
1-10
5
Microphone sensitivity
0 (off)
1-10
5
Language
Language of the
country
Contrast
1-40
20
Configuration
code-protected service
menu for trained dealers
-
Time/date
indiv. setting
-

THERA-VITAL
APPENDIX USER MANUAL
14 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Menu structure Control and display unit with 10.4" colour screen incl.
touch function
1st level
2nd level
Adjustable values, func-
tions
Factory settings
Neuro
Training time
1-180 min.
15 min.
Direction of rotation auto-
matic
on/off
off
Biofeedback
Symmetry bar
Symmetry road
passive
off
Symmetry bar
(smiley for upper
body training)
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Spasm program
forward
backward
alternating
follow
forward
Autom. speed
adaptation
on/off
off
Heart rate limit
60-150/min
100/min
Ortho
Training time
1-180 min.
15 min.
Biofeedback
(inactive for upper body
training)
Symmetrybar
Symmetry road
passive
off
Symmetry bar
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Muscle support
on/off
on
Heart rate limit
60-150/min
100/min
Cardio
Training time
1-180 min.
15 min.
Biofeedback
(inactive for upper body
training)
Symmetrybar
Symmetry road
passive
off
Symmetry bar
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Heart rate limit
60-150/min
100/min

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 15
Last update: CW16/2015
1st level
2nd level
Adjustable values, func-
tions
Factory settings
Isokinetic
Training time
1-180 min.
15 min.
Biofeedback
Symmetry bar
Symmetry road
passive
off
Symmetrybar
(smiley for upper
body training)
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Spasm program
forward
backward
alternating
follow
forward
Heart rate limit
60-150/min
100/min
Keeper
Training time
1-180 min.
15 min.
Level of difficulty
easy
medium
difficult
easy
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Heart rate limit
60-150/min
100/min
Hedgehog
(exclusive-
ly for leg
exercise)
Training time
1-180 min.
15 min.
Level of difficulty
easy
medium
difficult
easy
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medi
um
rough
medium
Max. symmetry
70%
80%
90%
100%
80%
Heart rate limit
60-150/min
100/min

THERA-VITAL
APPENDIX USER MANUAL
16 Art. no.: A004-791_Rev 01
Last update: CW16/2015
1st level
2nd level
Adjustable values, func-
tions
Factory settings
Car
(exclusi-
velyfor leg
exercise)
Training time
1-180 min.
15 min.
Level of difficulty
easy
medium
difficult
easy
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Lane preselection
left
random
right
frontal
random
Heart rate limit
60-150/min
100/min
Planet
Training time
1-180 min.
15 min.
Level of difficulty
easy
medium
difficult
easy
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
fine
medium
rough
medium
Heart rate limit
60-150/min
100/min
Group
therapy
(available
as additio-
nal option)
Training time
1-180 min.
15 min.
Motor power
2-22 Nm
(2-8 Nm for upper body
exerciser)
10 Nm
Spasm detection
low
medium
high
medium
Heart rate limit
60-150/min
100/min
Basic set-
tings
Volume
0 (off)
1-10
5
Microphone sensitivity
0 (off)
1-10
5
Language
Language of the
country
Contrast
1-40
20
Configuration
code-protected service
menu for trained dealers
-
Time/date
indiv. setting
-

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 17
Last update: CW16/2015
Basic settings in menu section Basic settings:
Volume
Microphone sensitivity
Language
Contrast
Configuration (trained dealer)
Time/date
It is possible to set the necessary configuration under menu item Configuration.
The configuration requires an access code and is exclusively to be used by
trained dealers.
Value range: between 1 and 180 minutes.
Factory setting: 15 min. Training time
If automatic direction of rotation is activated
the direction of rotation will change every four minutes during passive trai-
ning.
During active training exercise, the direction of rotation will not change.
Only the training programs Neuro, Ortho, Cardio and Isokinetic permit chan-
ging the biofeedback.
Shows biofeedback Symmetry bar or Symmetry road as factory setting.
Setting options in sub menu:
–Symmetry road
–Symmetry bar
–passive
–off
It is possible to limit the maximum motor power in the sub menu.
The motor power allows individual settings for every training program.
Automatic direc-
tion of rotation
Biofeedback
Motor power
Risk of injury due to inappropriate motor power!
Before every training session and every time when changing
the training program, check motor power setting.
Warning
Enables setting the barrier at which the sensor system recognizes an impermis-
sible user's movement and in order to minimize the risk of overstrain, stops the
motor.
The larger the crank radius, e.g. the lower the motor power, the more sensi-
tive the reactions of the anti-spasm-control system.
Setting options:
low
–Users with very sensitive joints and tendons.
–Motor will stop even at slight resistance.
medium
–Users with less sensitive joints.
high
–Users with severe spasms. Motor will stop only at strong resistance.
Spasm
detection

THERA-VITAL
APPENDIX USER MANUAL
18 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Spasm
program Enables setting the direction of rotation in which the exercise will resume after a
spasm has been recognized.
Setting options:
forward
–always start in forward direction after a spasm was recognized (recom-
mended if user tends to have stretch spasms)
backward
–always start in backward direction after a spasm was recognized (recom-
mended if user tends to have flexion spasms)
alternating
–change direction of rotation after a spasm was recognized
follow
–start in direction used previous to spasm being recognized
Automatic
speed
adjustment
When the automatic speed adjustment is set to ON, the passive lead speed
(motor) will automaticallyadapt itself during active exercise to a higher perfor-
mance made be the user.
Upper limit: 35 rpm
Example If the user is working at 30 rpm instead of the set number of revolutions (lead
speed) of 15 rpm, the THERA-vital will adjust the lead speed to 25 rpm after approx.
10 seconds. If the user becomes passive again, THERA-vital continues at 25 rpm.
The users acquires his individual speed and if he becomes passive, the exercise
will continue at the number of revolutions comfortable to him.
Heart rate limit THERA-vital reduces exercising resistance as soon as the set pulse rate is
reached. This makes sure that during training sessions, the user's pulse rate
always stays below the limit set by the doctor.
The heart rate limit allows individual settings for every training program.
Warning
Risk of injury due to inappropriate heart rate limit!
Before every training session and every time when changing the
training program, check setting for heart rate limit using a
cardio-pulse-set.
Use heart rate limit exclusively in combination with control and display unit
and cardio-pulse-set.
Set a larger crank radius for training programs that require a higher active
performance (Ortho, Cardio).
Muscle
support This function supports users with very low or one-sided residual power. This func-
tion supports the available residual power in such a way that smooth rotation is
guaranteed at all times.
Active muscle support
boosts the user's activity
takes over the work of the inactive side and acts as an electronicflywheel
for users with amputated legs.

THERA-VITAL
APPENDIX USER MANUAL
Art. no.: A004-791_Rev 01 19
Last update: CW16/2015
Set level of difficulty for training programs Keeper, Hedgehog, Car and Planet in
sub menu (exclusively for control and display unit with 10.4’’ colour screen).
3 steps:
easy
medium
difficult
Level of
difficulty
To set volume in sub menu Basic settings:
–Loudspeakers of control and display unit
–Volume of control buttons
–Acoustic feedback of training programs
Value range: 0 (off) to 10
A too high volume might activate the voice-controlled emergency stop.
A symbol in the status bar indicates the status.
Permits voice-controlled emergency stop
(see Safety devices).
To set microphone volume of control and display unit in menu
Basic settings/Microphonesensitivity:
A symbol in the status bar indicates the status.
0 (off)
–whentoo loud ambientnoisecausesthe THERA-vital to switchoff
inadvertently
1 - 3
–for very loud ambient noise
4 - 6
–for normal ambient noise
7 - 10
–for very little ambient noise
Perform a practical test to check whether setting is correct.
Press START button to continue the training session.
26 languages are available.
Factory setting: language of the country of delivery
Adjust contrast of colour screen in menu Basic settings/Contrast.
Set date and time in sub menu:
when switching between summer and winter daylight saving time.
after THERA-vital has been without power supply for a longer period
of time.
for training documentation and report with software package Cycling docu-
mentation and report.
for printer for training documentation.
Volume
Microphone
sensitivity
Language
Contrast
Time/date
See table Menu structure.
Settings will remain unchanged if the power supply is cut off. The training
session will start with the same settings.
Basic settings
Training
Reset to factory settings:
Press and hold STOP button.
Press button Direction of rotation at the same time.
Factory settings are restored.
The settings in the section Basic settings remain unchanged.
Factory settings

THERA-VITAL
APPENDIX USER MANUAL
20 Art. no.: A004-791_Rev 01
Last update: CW16/2015
Training programs/Training
To start training program:
Press START button.
To stop training program:
Press STOP button.
To end training program:
Press STOP button twice.
Leg exercise:
Set height of safety handle or upper body exerciser so that thighs/knees do
not collide with it.
Lock cranks of upper body exerciser in horizontal position.
Do not use safety handle as standing aid.
Make sure that height adjustment system is securely tightened.
Exercise exclusively with two foot rests.
Make sure that feet are secured.
Arm exercise:
Exercise exclusively with two therapy grips or two arm rests.
Do not put feet into foot rests during upper body training.
Make sure that arm rests are safely attached to therapy grips or cranks when
exercising the upper body.
Make sure it is not possible for arms to inadvertently loosen out of arm rests.
Neuro (basic set-
ting) Training program for users with neurological disorders such as hemiplegia, para-
plegia, multiple sclerosis, Parkinson's disease.
Training type: pre-set resistance.
Exercisingresistancesettingwill remain constantwithinthe entire rpm range.
Higher pedalling frequency = higher performance
Ortho Training program for users with orthopedic problems, e.g. after knee or hip sur-
gery.
Required performance level is pre-set.
ThetrainingprogramOrthoprescribesthe performance level for theexercise
inWatts.
THERA-vital regulates the exercising resistance automatically depen-
ding on the number of revolutions, so that the required performance always
remains at the selected level.
Other manuals for THERA-VITAL
1
Table of contents
Other THERA-Trainer Medical Equipment manuals
Popular Medical Equipment manuals by other brands

KaVo
KaVo LUX 540 LED U Instructions for use

Thinklabs
Thinklabs Rhythm ds32a user manual

Haemonetics
Haemonetics Cell Saver manual

Smiths Medical
Smiths Medical Graseby 1200 Quick reference guide

Villa
Villa Insecticide BIOMECTIN 18 EC manual

Elite Medical
Elite Medical Multi-Mode Stimulator instruction manual

Otto Bock
Otto Bock BetaSil 616S5-1 Instructions for use

Vitalograph
Vitalograph asma-1 4000 quick start guide

REH4MAT
REH4MAT AKVOSEGO user manual

Vermeiren
Vermeiren Interval Series instruction manual

Fillauer
Fillauer Motion Control MC ETD Wrist Disarticulation manual

Accutome