Thermador ®
INSTALLATION INSTRUCTIONS HANUAL
STEEL GAS STAR COOKTOPS
30" HODELS: SGS304, SGSX304
36" HODELS: SGS36S, SGSX36S
4S" HODELS: SGS4S6, SGSX4S6
PLEASE READ INSTRUCTION BEFORE PROCEEDING
IHPORTANT: Save these instructions for the local electrical inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Important Safety Instructions
• Installation must conform with local codes or, in
the absence of local codes with the National Fuel
Gas Code,ANSI Z223. I.
• The appliance must be electrically grounded in ac-
cordance with local codes or, in the absence of
local codes,with the National Electrical CodeANSI/
NFPA 70, latest edition. (In Canada, installation must
be in accordance with the CAN I-BI49.1 and .2
Installation Codes for Gas BurningAppliances and/
or local codes )
• This appliance has been tested in accordance with
ANS Z2 I. I, Standard for Household CookingAp-
pliances (USA) and in accordance with CANI.I-M8 I
Interim Reqt #58 Domestic Gas Cooktops
(CANADA).
_ WARNING: Improper installation, ad-
justment, alteration, service or mainte-
nance can cause injury or property damage. Refer
to this manual. For assistance or additional in-
formation consult a qualified installer, service
agency, manufacturer or the gas supplier.
• This appliance is equipped with an intermittent]
interrupted ignition device. (Models SGSX304,
SGSX365 and SGSX456 only)
• The cool(top must be used in conjunction with a
suitable ventilation system.
Power Requirements and Grounding
Power Supply: 120Volts, ISAmpere, 60 Hz.This appliance is
factory equipped with a 5-foot power supply cord with a 3-
prong grounding plug (with polarized parallel blades).
TO PREVENT ELECTRICAL SHOCK,THE THIRD
GROUND PRONG SHOULD NOT UNDER ANY
ClRCUHSTANCES, BE CUT OR REHOVED. IT
MUST BE PLUGGED INTOA MATCHING GROUNDING
TYPE RECEPTACLE, CONNECTED TO A CORRECTLY
POLARIZED 120-VOLT CIRCUIT. A separate circuit is rec-
ommended.
If there is any doubt as to whether the wall receptacle
is property grounded, the customer should have it
checked by a qualified electrician.
CAUTION: Before you plug in an electrical cord, be
sure all controls are in the OFF position.
Gas Requirements
Supply Pressure
Natural Gas - 6 inches water column
(14.9 Millibars) minimum.
Propane Gas - I I inches water column
(27.4 Millibars) minimum.
The maximum supply pressure to this appliance shall
not exceed 14.0 inches water column (34.9MB).
PROPANE GAS INSTALLATION
The propane gas tank must be equipped with its own
high pressure regulator in addition to the pressure regu-
lator supplied with this unit.
The cool<top is shipped from the factory for use with
natural gas. For use with LP conversion Idt - Model
SNLPKIT6, must be purchased separately. A qualified
technician or installer must do the conversion.
Leak testing of the appliance shall be conducted
according to manufacturer's instructions.