2.4 Location
Note the following precautions when locating the Phoenix
D385:
INDOORS ONLY.
GROUND
FAULT CIRCUIT INTERRUPT (GFCI) OUTLETS
1 foot from walls and other air flow obstructions.
improved by adding an outlet duct to circulate process
air to stagnant areas.
DO NOT use the Phoenix D385 as a bench or table.
2.5 Electrical Requirements
two separate circuits each with a minimum of 11 amps
dedicated capacity available.
The D385 has two separate power cords, each cord must
plugged into the same 15 amp circuit this circuit will trip
when the unit is turned on.
Another situation to avoid is that one or both of the
circuits which the D385 is using can be tripped by other
appliances drawing power from either circuit. This can
happen well after a job site has been set-up as in the case
with a freezer compressor turning on.
Care must be taken to insure that the D385 always has
sufficient power available to run without tripping breakers
or blowing fuses.
gauge minimum for one extension less than 25ft in length
or 12 gauge for one extension less than 50ft in length.
2.6 Control Panel
2.6A Power Switch
The D385 has one control device, the power switch.
portable desiccant is dehumidifying. The machine will
continue to dehumidify in all conditions until the power is
2.6B Pilot Light
The power indicator lamp illuminates to indicate that the
D385 is functioning properly. This indicator is helpful when
properly. At a glance from across the room the operator
can verify that the D385 is operating as it should.
2.6C Hour Meter
The hour meter will run whenever your D385 is on.
This digital hour meter measures the cumulative time
of operation in one-tenth hour increments. This non-
resettable time is often used to verify hours on a job or
the timer will continue to hold and display the cumulative
hours run.
2.7 Ducting Connections
job at hand needs a short length of duct, cut a section to
length, performance will suffer. The same can be said of
excess bends in the ducting.
Three different duct sizes are used on the D385. All
Process in: 12” flex duct.
To attach flex duct to the process air intake, push the wire
of the first couple of loops down below the four tabs in the
top cover.
Process out: 10” diameter lay flat plastic duct.
ducting attaches to the D385 by means of a 12”x 6” wire
rectangle. To attach lay flat ducting to the process exhaust
center and roll the plastic ducting’s end outward so that
it overlaps the outside of the collar. The duct and collar
Reactivation in & out: 6” flex duct.
connections.
The 6” flex ducting connections on the D385 consist
of a detachable 6” starting collar. Slide 6” flex ducting
over the starting collar and zip-tie or duct tape in place.
out from the cabinet. Flex duct and collar may be stored
beneath top cover.