2
USEPHOENIX.COM
1.800.533.7533
Table of Contents
Introduction ...............................................................................1
1. Safety ..................................................................................2
2. Specifications ....................................................................2
3. Operation ............................................................................2
3.1 Transporting ................................................................3
3.2 Electrical Requirements ............................................3
3.3 Condensate Removal ................................................3
3.4 Ducting .........................................................................3
3.5 Defrost Cycle ...............................................................3
3.6 Power Button ..............................................................3
3.7 Purge Button ...............................................................3
3.8 Hour Meter ..................................................................3
3.9 Hours Button ...............................................................3
3.10 Defrost Light .............................................................3
4. Maintenance ......................................................................4
4.1 Air Filter .......................................................................4
4.2 Storage ........................................................................4
5. Service ................................................................................4
5.1 Technical Description ................................................4
5.2 Troubleshooting ..........................................................5
5.3 Air Mover .....................................................................6
5.4 Thermistor ...................................................................6
5.5 Condensate Pump .....................................................6
5.6 Float Safety Switch ....................................................6
6. Options & Accessories .....................................................6
7. Wiring Diagram .................................................................7
8. Service Parts ......................................................................8
Warranty .............................................................................9
1 Safety
The R150 conforms to unified standard UL 60335-2-40
• Never operate a unit with a damaged power cord. If
the power cord is damaged it must be replaced by the
manufacturer, its service agent, or similarly qualified person
in order to avoid a hazard.
• The unit shall be installed in accordance with national
wiring regulations.
• Do not obstruct the air intake and exhaust. Maintain a .3
m (1 ft) clearance around the air intake and exhaust.
• This appliance is not intended for use by persons
(including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
2 Specifications
Part No. 4031250
Power 5.5 amps, 110-120 VAC, Grounded
Water 75 pints/day @ AHAM (80°F, 60%)
Removal 18 gallons/day maximum @ saturation
Process Air 150 CFM without external ducting
Refrigerant 1 lb, 4 oz. R410a
Charge
Operating 33°F to 110°F
Range
Filter 12” x 12” x 1” Pleated Media MERV-8
Duct
Options Outlet – 10” Lay-Flat
Warranty Five years;
1st year 100% of Parts and Labor
2nd-5th year 100% of Parts of sealed
refrigeration system.
Size 30” high x 20” wide x 17” deep
Weight 82 lbs
Patents 7,246,503
8,938,981
3 Operation
Place dehumidifier inside structure, place condensate
hose into a drain, or a very large container, and turn on. To
decrease drying times, make sure all windows and doors
are closed to the outside and seal off the wet area from any
unaffected areas.
Read the operation and maintenance instructions
carefully before using this unit. Proper adherence to these
instructions is essential to obtain maximum benefit from
your R150 dehumidifier.
• It is designed to be used INDOORS ONLY.
• If used in a wet area, plug it into a GROUND FAULT
INTERRUPTER.
• DO NOT use the R150 as a bench or table.
• It must always be used in the upright position.