Page 2 www.THUNDERSTONEMFG.com 402.435.4249
EZ FlowXR Hydraulic Trap - Manual Override System
How to use the manual open system.
oLocate poppet valve buttons behind the motor on the blocking valve.
The Top Button (1) is for front door.
The Bottom Button (2) is for rear door
oPush & hold each button individually for approx. 15 secs or until system is depressurized.
oWhen system has been depressurized, unlatch quick release pin from cylinder & remove.
oRepeat this step on all cylinders as needed.
oDoor(s) are now disconnected from the cylinders and can now be operated manually.
oRemove the straps from the storage box mounted on the motor bracket.
oHook the straps to the door by placing the hooks into the holes in the door.
oSlide the straps through the slots in the shaft at least 6”.
oTurn the crank shaft by hand to wind the strap onto the shaft until it gets tight.
oUsing the dolly crank turn the shaft and pull open the door until the hooks are close to the crank shaft.
oRemove the hooks from the door.
oWhen the tub is mostly empty pull the door by hand to finish opening and emptying the tub.