LED400PIRB.1 Instructs_147x105-R2a 1-6 15-08-14 1.20pm
Prepared by Sally
12 3 456
RM CODE : 1-MANL-TGAD32W N2 (FRONT)
1. Designated Use
•LED400PIR is an outdoor motion detector for automatic LED lighting control
•Suitable for installation on walls
•Simple plug in wall plate for easy & safe connection
•Suitable for a wide range of locations: corridors, gardens, staircases,
entrances, garages, outdoor parking areas etc.
Index :
Page 2 Contents, Tools required.
Page 3 Product dimensions.
Page 4 Installation procedure.
Page 5 Sensor detection range .
Page 6 Walk test & adjustment, Detector head adjustment.
Page 7 Knob settings.
Page 8 Lens masking.
Page 9 Lamp adjustment
2. Basic Safety Instruction
Danger of death through electric shock.
•Must only be installed by qualified electricians.
•Avoid the metal parts of the device due to potentially high temperature.
•Conforms to the latest directives.
•Designed for use in normal environments
•Intended for outdoor installation.
•Energy saving.
•Long LED bulb life.
Page 10 High temperature in lamp.
Test mode
90 90
0
2
Sec
2 sec
Detector Head Adjustment
The detector head can be panned 90 deg.
to the left and 90 deg. to the right.
Walk Test and Adjustment
The purpose of Walk Test is used to test and adjust the detection coverage of
LED400PIR under auto mode.
•Adjust the Time knob to “ T”, then conduct a walk test as described in test
procedure.
Test procedure:
•Adjust the Time knob to “ T ”, (Lux knob can be “Sun” or Moon”).
•Walk across the detection area, once the detector is triggered and the lamp
will turn ON for 2 seconds.
Note walking direction when performing test.
* Do not use the adjuster knobs to turn
the detector head.
10
20
30
40
45
10
20
30
40
45
Installation Advise:
As the detector reacts to variations in temperature, avoid situations:
•Do not install motion detectors near heat sources such as heating outlets, air
•Do not direct the motion detector at objects that move in the wind such
as curtains, large plants etc.
•Take account of motion direction during test run.
Detection Range:
LED400PIR: Recommended installation height is 2.3 meter above ground, the
maximum detection range about 12 meter and at the angle of about 180 deg.
WARNING
10
20
30
40
45
WARNING
1m
5 m
12 m
180°
6 m
180°
12m
6m
1m 0.5m
180°
•Do not direct motion detectors at objects with highly-reflective surface such as
mirrors etc.
conditioning systems, lamps etc.
3. Contents:
What’s in the box?
4. Tools required:
X 1 X 1
X 1
Tools / Equipment need for installation.
INSTRUCTION
MANUAL
X1
X1 X1
X2
X2
X1
5. Product Dimensions:
179.00
131.00
108.00
161.00
86.00
179.00
292.00
108.00
31.00
Spacer dimension:
15.00 104.00
91.00
* The Spacer is an optional fitting
which gives maximum Pan angle.
6. Connection:
2
5
3
14
6
7
60mm
Fix the spacer
to the wall plate
- if required.
7. Installation Procedure:
Switch off
the power.
Connect device to mains.
The device requires a warm-up
phase of approx. 35 seconds.
Connect the mains supply cable to the
terminal block on the backplate as follows.
For additional lighting, connect the external load
to the terminal box on the back plate as shown.
( See connection diagram )
CONNECTION:
8
Feed the wires through rubber gasket of the wall plate with spacer and attach to
corresponding terminal.
Fix the spacer with the wall plate to the wall or the wall plate alone.
Plug motion detector into base and tighten screw.
Remove protective foil before power-on the device.
Unscrew the
wall plate.
240V
9
Use the spacer if necessary.
CAUTION:
Push and open
the wall plate.
MOUNTING SCREW x 2
SWITCH LIVE
NEUTRAL
EARTH
BLUE
GREEN / YELLOW
BROWN
Push
The above diagram signifies the earth parking of additional cable from the mains. In such a case,
end user does not need to cut the additional wire from the mentioned.
Earth Parking
LIVE
NEUTRAL
EARTH
BLUE
GREEN / YELLOW
BROWN
L’
N
L
N
6mm
Parallel Switching & Master-Slave connection
A maximum of 20 LED400PIR floodlights can be wired in parallel
to enable any detector to turn ON all the lights connected.
You are also able to connect up to 5 slave floodlights at the same
time. Please refer to the diagram above which shows an example
of 2 PIR units connected in parallel, with 2 slave units in between.
Max. Wire
2 x 2.5m²
per way
NL’L
N
L
NLL’
control circuit control circuit