General Wiring Requirements
The EF-45 requires at least the following wiring:
•Ethernet cable: Cat5 cable or better is recommended.
•Power input cable
-AWG 22: less than 5 meters (Max. 7.5m)
•Power Input requirement: 12VDC +/- 5%, minimum 42W (12VDC @ 3.5 amps)
Note: Use stable power supply and shorter power input cable if possible with
correct gauge wire. Any over- or under-voltage applied to this unit may cause
permanent damage and void the warranty.
Standard Installation to Wall Surface or Gang Box
Detach the installation plate from the EF-45 by removing the screw (M3 x 6mm) at the
bottom of unit. Separate the wall plate from the rear cover by sliding the plate
downward. Screw will be re-used to attach the EF-45 to the wall plate following
installation of the wall plate and wiring.
•Installation can be accomplished by mounting directly to a wall (Surface Mount)
or to a Gang Box.
•For a Surface Mount installation, place the installation (wall) plate on the desired
wall location and screw into wall as indicated in the Surface Mount diagram
below. Ensure that bottom tab in plate faces outward and cable routing
opening in EF-45 matches opening in wall. Utilization of wall anchors is
mandatory.
replaced with a M3 security