TLV PowerDyne HR80A User manual

172-65165MA-05 (HR80A) 13 September 2021
Thermodynamic Steam Trap
HR80A
Copyright © 2021 by TLV CO., LTD.
All rights reserved
TM

172-65165MA-05 (HR80A) 13 Sep 2021
1
Contents
Introduction .......................................................................1
Safety Considerations.......................................................2
Checking the Piping..........................................................3
Specifications....................................................................4
Configuration.....................................................................5
Installation.........................................................................6
Maintenance......................................................................7
Disassembly/Reassembly.................................................8
Troubleshooting ..............................................................10
TLV EXPRESS LIMITED WARRANTY...........................11
Service............................................................................13
Introduction
Thank you for purchasing the TLV PowerDyne thermodynamic steam trap.
This product has been thoroughly inspected before being shipped from the
factory. When the product is delivered, before doing anything else, check the
specifications and external appearance to make sure nothing is out of the
ordinary. Also be sure to read this manual carefully before use and follow the
instructions to be sure of using the product properly.
The HR80A PowerDyne thermodynamic steam trap can be used without
adjustment from 0.8 to 8 MPaG (115 to 1150 psig) on medium-load
applications. It is suitable for discharge of condensate at a temperature
slightly lower than saturation temperature from steam mains, tracers, etc.
If detailed instructions for special order specifications or options not contained
in this manual are required, please contact TLV for full details.
This instruction manual is intended for use with the model(s) listed on the
front cover. It is necessary not only for installation but for subsequent
maintenance, disassembly/reassembly and troubleshooting. Please keep it in
a safe place for future reference.

172-65165MA-05 (HR80A) 13 Sep 2021
2
Safety Considerations
•Read this section carefully before use and be sure to follow the instructions.
•Installation, inspection, maintenance, repairs, disassembly, adjustment
and valve opening/closing should be carried out only by trained
maintenance personnel.
•The precautions listed in this manual are designed to ensure safety and
prevent equipment damage and personal injury. For situations that may
occur as a result of erroneous handling, three different types of cautionary
items are used to indicate the degree of urgency and the scale of potential
damage and danger: DANGER, WARNING and CAUTION.
•The three types of cautionary items above are very important for safety: be
sure to observe all of them as they relate to installation, use, maintenance,
and repair. Furthermore, TLV accepts no responsibility for any accidents or
damage occurring as a result of failure to observe these precautions.
Symbols
Indicates a DANGER, WARNING or CAUTION item.
Indicates an urgent situation which poses a threat of death or
serious injury
Indicates that there is a potential threat of death or serious injury
Indicates that there is a possibility of injury or equipment / product
damage
Install properly and DO NOT use this product outside the
recommended operating pressure, temperature and other
specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions that may lead to serious accidents. Local
regulations may
restrict the use of this product to below the conditions quoted.
Take measures to prevent people from coming into direct
contact with product outlets.
Failure to do so may result in burns or other injury from the
discharge of fluids.
When disassembling or removing the product, wait until the
internal pressure equals atmospheric pressure and the surface
of the product has cooled to room temperature.
Disassembling or removing the product when it is hot or under pressure
may lead to discharge of fluids, causing burns, other injuries or damage.
Be sure to use only the recommended components when
repairing the product, and NEVER attempt to modify the
product in any way.
Failure to observe these precautions may result in damage to the
product and burns or other injury due to malfunction or the
discharge of fluids.
Use only under conditions in which no freeze-up will occur.
Freezing may damage the product, leading to fluid discharge, which
may cause burns or other injury.
Use only under conditions in which no water hammer will occur.
The impact of water hammer may damage the product,
leading to fluid discharge, which may cause burns or other injury.
DANGER
WARNING
CAUTION
CAUTION

172-65165MA-05 (HR80A) 13 Sep 2021
3
Checking the Piping
Use only under conditions in which no water hammer will occur.
The impact of water hammer may damage the product, leading to fluid
discharge, which may cause burns or other injury.
Check to make sure that the pipes to be connected to the product have been installed
properly.
1. Is the pipe diameter suitable?
2. Has sufficient space been secured for maintenance?
3. Have isolation valves been installed at the inlet and outlet? If the outlet is subject
to back pressure, has a check valve been installed?
4. Is the inlet pipe as short as possible, with as few bends as possible, and installed
so the liquid will flow naturally down into the product?
5. Has the piping work been done correctly, as shown in the figures below?
Requirement
Correct
Incorrect
Install catchpot with the
proper diameter.
Diameter is too small.
Make sure the flow of
condensate is not
obstructed.
Diameter is too small and
inlet protrudes into pipe
interior.
To prevent rust and scale
from flowing into the trap,
the inlet pipe should be
connected 25 – 50 mm (1
– 2 in) above the base of
the T-pipe.
Rust and scale flow into the
trap with the condensate.
When installing on the
blind end, make sure the
flow of condensate is not
obstructed.
Condensate collects in the
pipe.
CAUTION

172-65165MA-05 (HR80A) 13 Sep 2021
4
Specifications
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions that may lead to serious accidents. Local regulations may restrict
the use of this product to below the conditions quoted.
Use only under conditions in which no freeze-up will occur. Freezing may
damage the product, leading to fluid discharge, which may cause burns or other
injury
Refer to the product nameplate for detailed specifications.
A
Nominal Diameter
B
Valve No.**
C
Maximum Allowable Pressure (PMA) *
D
Maximum Operating Pressure (PMO)
E
Model
F
Production Lot No.
G
Maximum Allowable Temperature (TMA)*
H
Maximum Operating Temperature (TMO)
Minimum Operating Pressure: 0.8 MPaG (115 psig)
Back pressure should not exceed 50% of the inlet pressure
* Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are
PRESSURE SHELL DESIGN CONDITIONS, NOT OPERATING CONDITIONS.
** Valve No. is displayed for products with options. This item is omitted from the nameplate
when there are no options.
CAUTION
A
B
C
D
E
F
G
H

172-65165MA-05 (HR80A) 13 Sep 2021
5
Configuration
No.
Name
M*
R*
1
Body
2
Cover
3
Module Valve Seat
4
Disc
5
Air Vent Ring (Bimetal)
6
Disc Holder Ring
7
Module Gasket (Large)
8
Module Gasket (Small)
9
Screen
10
Cover Bolt
11
Nameplate
12
Cap
13
Set Screw
14
Guide Pin
15
Flange
*Replacement parts are available only in the following kits: M = Maintenance Kit; R = Repair Kit

172-65165MA-05 (HR80A) 13 Sep 2021
6
Installation
Install properly and DO NOT use this product outside the recommended
operating pressure, temperature and other specification ranges.
Improper use may result in such hazards as damage to the product or
malfunctions that may lead to serious accidents. Local regulations may restrict
the use of this product to below the conditions quoted.
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from the
discharge of fluids.
NOTE: For products with socket weld connections, electric weld with a single pass.
As internal parts are not damaged by the welding process when it is limited to a
single pass, there is no need to remove them before welding.
Installation, inspection, maintenance, repairs, disassembly, adjustment and valve
opening/closing should be carried out only by trained maintenance personnel.
1. Before installation, be sure to remove all protective seals.
2. Before installing the product, open the inlet valve and blow out the piping to
remove any piping scraps, dirt and oil. Close the inlet valve after blowdown.
3. Install the product so the arrow on the body is pointing in the direction of flow.
4. The trap may be installed either horizontally or vertically; there are no restrictions
on the orientation of installation. (Fix the trap securely in place.)
5. Install a condensate outlet valve and outlet piping. Make sure that the outlet
piping is large enough to prevent occurrence of excessive backpressure.
(Backpressure must not exceed 50% of the inlet steam pressure.)
6. To make sure that the product functions properly, first open the outlet valve fully.
Next carefully perform the following start-up procedure:
IMPORTANT START-UP PROCEDURE
To ensure proper operation, slowly open the inlet valve slightly. Initially OPEN THE
VALVE ONLY 1/32 TURN in order to supply steam to the trap very slowly then WAIT
FOR AT LEAST 30 SECONDS for air to vent before fully opening the inlet valve.
If there is a problem, determine the cause using the “Troubleshooting” section in this
manual.
CAUTION
Horizontal Vertical

172-65165MA-05 (HR80A) 13 Sep 2021
7
Maintenance
Take measures to prevent people from coming into direct contact with
product outlets. Failure to do so may result in burns or other injury from the
discharge of fluids.
Be sure to use only the recommended components when repairing the
product, and NEVER attempt to modify the product in any way. Failure to
observe these precautions may result in damage to the product or burns or other
injury due to malfunction or the discharge of fluids.
Operational Check
A visual inspection of the following items should be done on a daily basis to
determine whether the trap is operating properly or has failed. Periodically (at least
biannually) the operation should also be checked by using diagnostic equipment,
such as a stethoscope, thermometer, TLV Pocket TrapMan* or TLV TrapMan*.
If the product should fail, it may cause damage to piping and equipment, resulting in
faulty or low quality products or losses due to steam leakage.
Normal
:
Condensate is discharged intermittently together with flash
steam, and the sound of flow can be heard.
Blocked
(Discharge Impossible)
:
No condensate is discharged. The product is quiet and
makes no noise, and the surface temperature of the product
is low.
Blowing
:
Live steam continually flows from the outlet and there is a
continuous metallic sound.
Steam Leakage
:
Live steam is discharged through the product outlet together
with condensate, accompanied by a high-pitched sound.
(When conducting a visual inspection, flash steam is sometimes mistaken for steam
leakage. For this reason, the use of a steam trap diagnostic instrument [TLV: TrapMan*]
in conjunction with the visual inspection is highly recommended.)
*For products having operating conditions compatible with Pocket TrapMan and TrapMan
specifications.
Parts Inspection
When parts have been removed, or during periodic inspections, use the following
table to inspect the parts and replace any that are found to be defective.
Procedure
Gaskets : Check for warping or scratches
Screen : Check for clogging or corrosion
Disc : Check for scratches or wear
Disc Holder Ring : Check for scratches or wear
Air Vent Ring : Check for scratches or wear
Modular Valve Seat Surface : Check for scratches or wear
Check for build-up inside the body
CAUTION

172-65165MA-05 (HR80A) 13 Sep 2021
8
Disassembly/Reassembly
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the product has
cooled to room temperature.
Disassembling or removing the product when it is
hot or under pressure may lead to discharge of fluids, causing burns, other
injuries or damage.
Use the following procedures to remove components. Use the same procedures in
reverse to reassemble. (Installation, inspection, maintenance, repairs, disassembly,
adjustment and valve opening/closing should be carried out only by trained
maintenance personnel.)
Removing/Reattaching the Cap
Part
During Disassembly
During Reassembly
Set Screw
withWasher
13
Turn by screwdriver
Be careful not to damage the head
Cap 12
Lift the cap up and off
—
Cover Bolt
10
Remove with a
socket wrench;
loosen the bolts
little by little in an
alternating criss-
cross pattern
Consult the table of tightening
torques and tighten to the proper
torque; tighten the bolts little by little
in an alternating criss-cross pattern
until the gap between the body and
the cover closes; be sure to coat the
threads of the bolt with ant-seize
Cover 2
Lift up and off
Make sure there are no pieces of the
old gasket left on the sealing surfaces
Disassembly/Reassembly of Components Inside the Body
Part
During Disassembly
During Reassembly
Disc 4
Remove, being
careful not to scratch
the lapped surface
Make sure that the seat surface
(lapped side with groove) is facing
down, toward the valve seat
Disc
Holder
Ring 6
Remove without
bending
Set on the air vent ring and make
sure that it does not sit on the valve
seat surface
Air Vent
Ring 5
Remove without
bending, as it will
not return to its
proper shape
Reinsert without bending
Module
Gasket 7
Remove the gasket
Replace with a new gasket
Module
Valve
Seat 3 &
Guide Pin
14
Remove, being
careful not to scratch
the gasket sealing
surface; in the case
that the guide pin
becomes loose from
the module valve seat
during disassembly,
remove the guide pin
from the body
Make sure there are no pieces of
the old gasket left on the sealing
surfaces; insert the guide pin into
the hole on the body and reattach; i
f
the guide pin came loose from the
module valve seat, insert it into the
hole in the module valve seat before
attaching to the body
Module
Gasket 7
Remove the gasket
Replace with a new gasket
Screen 9
Remove without
bending
Reinsert without bending
Module
Gasket 8
Remove the gasket
Replace with a new gasket; make
sure there are no pieces of the old
gasket left on the sealing surfaces
of the body
CAUTION
13 12
10
2
1
6
7
14
81
9
7
3
5
4

172-65165MA-05 (HR80A) 13 Sep 2021
9
Table of Tightening Torques
Part Name
Torque
Distance Across Flats
N·m
(lbf·ft)
Mm
(in)
Cover Bolt
50
(37)
14
(9/16)
(1 N⋅m ≈10 kg⋅cm)
NOTE: - Coat all threaded portions with anti-seize.
- If drawings or other special documentation were supplied for the product, any torque
given there takes precedence over values shown here.
Exploded View
No.
Part Name
1
Body
2
Cover
3
Module Valve Seat
4
Disc
5
Air Vent Ring (Bimetal)
6
Disc Holder Ring
7
Module Gasket (Large)
8
Module Gasket (Small)
9
Screen
10
Cover Bolt
11
Nameplate
12
Cap
13
Set Screw
14
Guide Pin
7
9
8
1
6
4
5
32
10
13
12
7
14

172-65165MA-05 (HR80A) 13 Sep 2021
10
Troubleshooting
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the product has
cooled to room temperature.
Disassembling or removing the product when it is
hot or under pressure may lead to discharge of fluids, causing burns, other
injuries or damage.
When the product fails to operate properly, use the following table to locate the
cause and remedy.
Problem
Cause
Remedy
No condensate
is discharged
(blocked) or
discharge is
poor
Module valve seat, screen or piping
are clogged with rust or scale
Clean parts
Disc is stuck to the module valve seat
Clean parts
Air binding has occurred
Perform a bypass blowdown, or
close the trap inlet valve and allow
the trap to cool
- Disc holder ring has extensive wear
- Replace with a new disc holder
ring
- Bimetal air vent ring has extensive
wear
- Replace with a new bimetal air
vent ring
Steam-locking has occurred
Perform a bypass blowdown, or
close the trap inlet valve and allow
the trap to cool. Piping correction
may also be required.
Trap capacity is insufficient
Compare specifications and actual
operating conditions
Inlet pressure decreased further than
the pressure originally designed for, or
there is insufficient pressure differential
between the trap inlet and outlet
Compare specifications and actual
operating conditions
Steam is
discharged or
leaks from the
outlet
(blowing)
(steam leakage)
Rust or scale on the disc or on the seat
of the module valve seat
Clean parts
Disc and/or module valve seat damage
or wear
Replace with a new disc and/or
module valve seat
Gasket (lower module gasket)
deterioration or damage
Replace with a new gasket
Improper installation
Correct the installation
Trap vibration
Lengthen the inlet piping and
fasten it securely
The cover is loose
Tighten the cover bolt to the
proper torque
Trap operating pressure is less than
the minimum specified pressure
Compare specifications and actual
operating conditions
The back pressure exceeds the
allowable back pressure (back
pressure should not exceed
50% of the
inlet pressure)
Compare specifications and actual
operating conditions
Steam is leaking
from a place
other than the
outlet
Gasket (upper or middle module
gaskets) deterioration or damage
Replace with new gasket(s)
Improper tightening torques were used
Tighten to the proper torque
NOTE: When replacing parts with new, use the parts list for reference, and replace with parts
from the Maintenance Kit, Repair Kit, etc. Please note that replacement parts are only
available as part of a replacement parts kit.
CAUTION

172-65165MA-05 (HR80A) 13 Sep 2021
11
TLV EXPRESS LIMITED WARRANTY
Subject to the limitations set forth below, TLV CO., LTD., a Japanese corporation
(“TLV”), warrants that products which are sold by it, TLV International Inc. (“TII”) or one
of its group companies excluding TLV Corporation (a corporation of the United States of
America), (hereinafter the “Products”) are designed and manufactured by TLV, conform
to the specifications published by TLV for the corresponding part numbers (the
“Specifications”) and are free from defective workmanship and materials. The party
from whom the Products were purchased shall be known hereinafter as the “Seller”.
With regard to products or components manufactured by unrelated third parties (the
“Components”), TLV provides no warranty other than the warranty from the third party
manufacturer(s), if any.
Exceptions to Warranty
This warranty does not cover defects or failures caused by:
1. improper shipping, installation, use, handling, etc., by persons other than TLV,
TII or TLV group company personnel, or service representatives authorized by
TLV; or
2. dirt, scale or rust, etc.; or
3. improper disassembly and reassembly, or inadequate inspection and
maintenance by persons other than TLV or TLV group company personnel, or
service representatives authorized by TLV; or
4. disasters or forces of nature or Acts of God; or
5. abuse, abnormal use, accidents or any other cause beyond the control of TLV,
TII or TLV group companies; or
6. improper storage, maintenance or repair; or
7. operation of the Products not in accordance with instructions issued with the
Products or with accepted industry practices; or
8. use for a purpose or in a manner for which the Products were not intended; or
9. use of the Products in a manner inconsistent with the Specifications; or
10. use of the Products with Hazardous Fluids (fluids other than steam, air, water,
nitrogen, carbon dioxide and inert gases (helium, neon, argon, krypton, xenon
and radon)); or
11. failure to follow the instructions contained in the TLV Instruction Manual for the
Product.
Duration of Warranty
This warranty is effective for a period of one (1) year after delivery of Products to the
first end user.
Exclusive Remedy
THE EXCLUSIVE REMEDY UNDER THIS WARRANTY, UNDER ANY EXPRESS
WARRANTY OR UNDER ANY IMPLIED WARRANTIES NOT NEGATED HEREBY
(INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE), IS REPLACEMENT; PROVIDED: (a) THE CLAIMED DEFECT IS
REPORTED TO THE SELLER IN WRITING WITHIN THE WARRANTY PERIOD, INCLUDING
A DETAILED WRITTEN DESCRIPTION OF THE CLAIMED DEFECT AND HOW AND WHEN
THE CLAIMED DEFECTIVE PRODUCT WAS USED; AND (b) THE CLAIMED DEFECTIVE
PRODUCT AND A COPY OF THE PURCHASE INVOICE IS RETURNED TO THE SELLER,
FREIGHT AND TRANSPORTATION COSTS PREPAID, UNDER A RETURN MATERIAL
AUTHORIZATION AND TRACKING NUMBER ISSUED BY THE SELLER. ALL LABOR

172-65165MA-05 (HR80A) 13 Sep 2021
12
COSTS, SHIPPING COSTS, AND TRANSPORTATION COSTS ASSOCIATED WITH THE
RETURN OR REPLACEMENT OF THE CLAIMED DEFECTIVE PRODUCT ARE SOLELY
THE RESPONSIBILITY OF BUYER OR THE FIRST END USER. THE SELLER RESERVES
THE RIGHT TO INSPECT ON THE FIRST END USER’S SITE ANY PRODUCTS CLAIMED
TO BE DEFECTIVE BEFORE ISSUING A RETURN MATERIAL AUTHORIZATION. SHOULD
SUCH INSPECTION REVEAL, IN THE SELLER’S REASONABLE DISCRETION, THAT THE
CLAIMED DEFECT IS NOT COVERED BY THIS WARRANTY, THE PARTY ASSERTING
THIS WARRANTY SHALL PAY THE SELLER FOR THE TIME AND EXPENSES RELATED
TO SUCH ON-SITE INSPECTION.
Exclusion of Consequential and Incidental Damages
IT IS SPECIFICALLY ACKNOWLEDGED THAT THIS WARRANTY, ANY OTHER EXPRESS
WARRANTY NOT NEGATED HEREBY, AND ANY IMPLIED WARRANTY NOT NEGATED
HEREBY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, DO NOT COVER, AND NEITHER TLV, TII NOR ITS TLV
GROUP COMPANIES WILL IN ANY EVENT BE LIABLE FOR, INCIDENTAL OR
CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO LOST PROFITS, THE
COST OF DISASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT, INJURY TO
OTHER PROPERTY, DAMAGE TO BUYER’S OR THE FIRST END USER’S PRODUCT,
DAMAGE TO BUYER’S OR THE FIRST END USER’S PROCESSES, LOSS OF USE, OR
OTHER COMMERCIAL LOSSES. WHERE, DUE TO OPERATION OF LAW,
CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY, UNDER ANY
OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED
WARRANTY NOT NEGATED HEREBY (INCLUDING THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) CANNOT BE
EXCLUDED, SUCH DAMAGES ARE EXPRESSLY LIMITED IN AMOUNT TO THE
PURCHASE PRICE OF THE DEFECTIVE PRODUCT. THIS EXCLUSION OF
CONSEQUENTIAL AND INCIDENTAL DAMAGES, AND THE PROVISION OF THIS
WARRANTY LIMITING REMEDIES HEREUNDER TO REPLACEMENT, ARE INDEPENDENT
PROVISIONS, AND ANY DETERMINATION THAT THE LIMITATION OF REMEDIES FAILS
OF ITS ESSENTIAL PURPOSE OR ANY OTHER DETERMINATION THAT EITHER OF THE
ABOVE REMEDIES IS UNENFORCEABLE, SHALL NOT BE CONSTRUED TO MAKE THE
OTHER PROVISIONS UNENFORCEABLE.
Exclusion of Other Warranties
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
AND ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
ARE EXPRESSLY DISCLAIMED.
Severability
Any provision of this warranty which is invalid, prohibited or unenforceable in any
jurisdiction shall, as to such jurisdiction, be ineffective to the extent of such invalidity,
prohibition or unenforceability without invalidating the remaining provisions hereof,
and any such invalidity, prohibition or unenforceability in any such jurisdiction shall
not invalidate or render unenforceable such provision in any other jurisdiction.

172-65165MA-05 (HR80A) 13 Sep 2021
13
Service
For Service or Technical Assistance: Contact your TLV representative or your regional TLV office.
In Europe:
Daimler-Benz-Straße 16-18, 74915 Waibstadt, Germany
Tel:
Fax:
[49]-(0)7263-9150-0
[49]-(0)7263-9150-50
Units 7 & 8, Furlong Business Park, Bishops Cleeve, Gloucestershire GL52
8TW, U.K.
Tel:
Fax:
[44]-(0)1242-227223
[44]-(0)1242-223077
Parc d’Ariane 2, bât. C, 290 rue Ferdinand Perrier, 69800 Saint Priest,
France
Tel:
Fax:
33–(0)4-72482222
[33]-(0)4-72482220
In North America:
13901 South Lakes Drive, Charlotte, NC 28273-6790, U.S.A.
Tel:
Fax:
[1]-704-597-9070
[1]-704-583-1610
In Mexico and Latin America:
Av. Jesús del Monte 39-B-1001, Col. Hda. de las Palmas, Huixquilucan,
Edo. de México, 52763, Mexico
Tel:
Fax:
[52]-55-5359-7949
[52]-55-5359-7585
In Oceania:
Unit 8, 137-145 Rooks Road, Nunawading, Victoria 3131, Australia
Tel:
Fax:
[61]-(0)3-9873 5610
[61]-(0)3-9873 5010
In East Asia:
36 Kaki Bukit Place, #02-01/02, Singapore 416214
Tel:
Fax:
[65]-6747 4600
[65]-6742 0345
Room 5406, No. 103 Cao Bao Road, Shanghai, China 200233
Tel:
Fax:
[86]-(0)21-6482-8622
[86]-(0)21-6482-8623
No.16, Jalan MJ14, Taman Industri Meranti Jaya, 47120 Puchong,
Selangor, Malaysia
Tel:
Fax:
[60]-3-8065-2928
[60]-3-8065-2923
252/94 (K-L) 17th Floor, Muang Thai-Phatra Complex Tower B,
Rachadaphisek Road, Huaykwang, Bangkok 10310, Thailand
Tel:
Fax:
[66]-2-693-3799
[66]-2-693-3979
#302-1 Bundang Technopark B, 723 Pangyo-ro, Bundang, Seongnam,
Gyeonggi, 13511, Korea
Tel:
Fax:
[82]-(0)31-726-2105
[82]-(0)31-726-2195
In the Middle East:
Building 2W, No. M002, PO Box 371684, Dubai Airport Free Zone, Dubai, UAE
Email:
sales-[email protected]
In Other Countries:
881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, Japan
Tel:
Fax:
[81]-(0)79-427-1818
[81]-(0)79-425-1167
Manufacturer:
881 Nagasuna, Noguchi, Kakogawa, Hyogo 6758511, Japan
Tel:
Fax:
[81]-(0)79-422-1122
[81]-(0)79-422-0112
Other manuals for PowerDyne HR80A
1
Table of contents
Other TLV Plumbing Product manuals
Popular Plumbing Product manuals by other brands

ShowHouse
ShowHouse S412 Series user manual

Toto
Toto Comfort Wave TBW07017U Installation and owner's manual

American Standard
American Standard Afwall Flowise 3351.128 Specification sheet

Symmons
Symmons Naru Trim Series Installation & operation instructions

Transform
Transform QK022 installation manual

Whitehaus
Whitehaus WHFH-H1010 Installation sheet