VS-900
CONVENIENT FUNCTIONS
CALL-RELATED FUNCTION
GROUP CALL
A designated group of up to 16 master stations or telephones can be
called from any substation, which is answered from any called master
station (telephone).
[System pre-programming]
First, one of master stations (telephones) in a group must be programmed
as a representative station, and the rest as member stations. Then, a
calling substation must be programmed to call the representative station.
TRANSFER-RELATED FUNCTION
CALL TRANSFER
(1) Call transfer
A master station (or telephone) can transfer the conversation partner to
another master station (or telephone).
(2) Call Hold and Call Back
These functions enable the master station (or telephone) to temporarily
put the current conversation on hold (Call Hold), and return to the
original conversation (Call Back) after talking with a third party.
Note: Master station and telephone operation differs.
MONITOR-RELATED FUNCTION
SCAN MONITOR
Any master station can scan a designated group of substations for audio
monitoring of each substation.
[System pre-programming]
(1) Substations to be monitored (up to 16) can be registered for each
master station in system programming.
(2) Monitor interval times of 1 - 99 seconds (in 1 second units) for each
master station can be registered in the system programming.
CALL FORWARDING-RELATED FUNCTIONS
CALL FORWARDING
When away from one's desk, incoming calls can be automatically
forwarded to another receiving station. The receiving station*1number can
be registered at the original station (forwarding station). It is also possible
to active this feature from the destination receiving station.
[System pre-programming]
To use this function, enable the Call Forwarding function in system
programming.
TIME-BASED CALL FORWARDING
All incoming calls to the original station*1(forwarding station) can be
automatically rerouted to the designated master station*1(receiving station)
during a specific period of the day.
[System pre-programming]
(1) To use this function, the Time-Based Call Forwarding function
must be enabled in system programming.
(2) The forwarding interval (start and end times) can be registered
in the system programming. (Registration can only be performed for an
entire exchange. Different times cannot be set for different stations on
the same exchange.)
NO-ANSWER CALL FORWARDING
Calls to the original station*1(forwarding station) are automatically rerouted
to the designated receiving station*1
if the called party does not respond within a preset period of time.
[System pre-programming]
(1) To use this function, the No-Answer Call Forwarding function must be
enabled in system programming.
(2) Register a variable "no-response" time of 1 - 99 seconds (in 1 second
units) in the system programming.
(Registration can only be performed for an entire exchange. Different
times cannot be set for different stations on the same exchange.)
BUSY CALL FORWARDING
Calls to a busy station*2are automatically forwarded to a designated
station*2.
[System pre-programming]
To use this function, the Busy Call Forwarding function must be enabled in
system programming.
*
1
Both the forwarding and receiving stations must be either master stations or
telephones. Calls cannot be transferred to a substation.
*
2
The station which forwards calls (forwarded station) and the station to which calls
are forwarded (receiving station) must be either a master station or a telephone.
Calls cannot be forwarded to a substation.
PAGING-RELATED FUNCTIONS
ZONE PAGING
Permits paging to up to 19 individual zones (01 – 19) established by
combining multiple substations with external public address system
equipment. Two or more individual zones can simultaneously be selected.
[System pre-programming]
(1) The number of zone number digits (1 or 2 digits) can be registered in
system programming.
Single digit: Zone Nos. 1 - 9
Double digit: Zone Nos. 01 - 19
(2) Substation numbers and selective external public address equipment
outputs to be included in each zone can be registered in the system
programming. Up to 1,024 substations and up to 16 selective outputs
can be registered per zone.
Note: Only 1 voice output is made available for paging to external equipment. It is
impossible for 2 or more persons to simultaneously initiate paging.
ALL-ZONE PAGING
Paging calls can be simultaneously made to substations and external
public address equipment in the all programmed zones. (Paging calls are
not made to substations and external public address equipment not
assigned to zones.)
[System pre-programming]
(1) The number of digits (1 or 2) of an all-zone paging access number ([0]
or [0][0]) can be registered in system programming.
(2) Substation numbers and selective external public address equipment
outputs to be included in each zone can be registered in the system
programming. Up to 1,024 substations and up to 16 selective outputs
can be registered per zone.
EMERGENCY PAGING
Paging calls can be made to all connected master stations, substations,
and external public address equipment simultaneously.
[System pre-programming]
Master stations that can place Emergency Paging calls must be registered
in the system programming.
EXTERNAL SOURCE DISTRIBUTION
By activating the input, external sound sources can be distributed to pre-
programmed paging zones.
Permits source distribution to up to 19 individual zones (01 - 19)
established by combining multiple substations with external public address
system equipment. Two or more individual zones can simultaneously be
selected.
[System pre-programming]
Up to 9 (19) paging zones can be registered for each activation input (up to
4 inputs) in system programming.
(Up to 1,024 substations and up to 16 selective external public address
equipment outputs to be included in each zone are registered in the Zone
Paging system programming.)
PAGING TIME-OUT
Paging calls that exceed a set time limit are automatically terminated. (This
function is used mainly to prevent the line from being occupied because
the user forgot to turn off the function.) The Time-Out function is disabled
when an emergency paging call is placed.
[System pre-programming]
• Program whether to [Enable] or [Disable] the Paging Time-Out function.
• Paging time-out (10 - 990 seconds in 10 second units) common to both
Individual Zone and All-Zone Paging functions can be registered in the
system programming.
PAGING REDIAL
This function permits redialing the last-paged zone by simple key
operations.