TD-600
CONTENTS
General des ription
Part des ription
Conne tions
1. Power onne tion
2. Inter om line onne tion
3. Telephone line onne tion
4. Fa simile onne tion
Ex hange DIP swit h setting and programming
Signal mode adjustment and setting
1. Re eiving sound volume adjustment
2. Adjustment of urrent supplied to telephone
3. Jumper wire onne tion
4. Polarity reverse signal ontrol
Call operations
Installation
Spe ifi ations
A essories
GENERAL DESCRIPTION
By using the TD-600 telephone interfa e in onjun tion with TOA' s inter om ex hange,
a pushphone (*DTMF) an be used as a handset inter om station. Two pushphones an
be onne ted per interfa e.
2
3
4
4
5
6
6
7
8
9
10
10
11
12
12
– 2 –
DTMF=Dual tone multi-frequen y
PART DESCRIPTION
[Front view]
Power indi ator
CH1 telephone
hook-off indi ator
CH2 telephone
hook-off indi ator
[Rear view]
Earth terminal
(Be sure to ground.)
Power supply terminal
CH2 inter om line terminal
CH2 telephone line terminal
CH1 inter om line terminal
CH1 telephone line terminal
– 3 –
CONNECTIONS
1. Power onne tion
24V DC power supply
[AD-242A (2.5A) et ]
TD-600
2. Inter om line onne tion
2.1 When using EXES-6000 ex hange
CH2 inter om line terminal
CH1 inter om line
terminal
Twisted pair able et .
EXES-6000
series ex hange
BX-610/620
YR-810/801
TD-600
– 4 –
When using EX-200 ex hange
EX-200 ex hange
CH2 inter om line terminal
TD-600
inter om line
terminal
Twisted pair able et .
LM-20
Perform jumper wire settings as instru ted in page 9.
Telephone line onne tion
CH2 telephone line terminal
TD-600
CH1 telephone line
terminal
DTMF telephone
Usable telephones
1) DTMF type
2) Type with line impedan e of 600
2.2
3.
– 5 –
Note:
Fa simile onne tion
TD-600
CH1 telephone line terminal
To fa simile line
terminal
Fa simile
CH2 telephone line terminal
Usable fa similes are restri ted that sele ting signal is transmitted a pushphone.
EXCHANGE DIP SWITCH SETTING
AND PROGRAMMING
All the lines or ex hanges to onne t the TD-600 should be set to the ontinuous all tone.
1. When using EX-200 ex hange
Perform the handset station registration with the station No. 24.
Handset station No. Handset station No.
2. When using EX-600 ex hange
Set the DIP swti h (SW-B-1) of CP-60 to ON to sele t the ontinuous all tone.
3. When using EX-610/620/630 ex hange
Set the DIP swti h (SW-E-8) of CP-66 to ON to sele t the ontinuous all tone.
4.
– 6 –
Note:
SIGNAL MODE ADJUSTMENT AND SETTING
Perform the signal mode setting before the final installation or wiring work be ause the
setting requires the removal of the top over.
Remove side plate s rews (four pla es).
Deta h the top over.
1. RECEIVING SOUND VOLUME ADJUSTMENT
The re eiving sound volume an be adjusted in 8dB steps by swit hing SW3 setting
as shown in the figure below.
Position of SW3 is fa tory-preset to "1".
Note:
Position of SW3
1
2
3
4
Re eiving sound volume step
0dB
+
8dB
+
16dB
+ 24dB
Position 1 of SW3 is set to 0dB.
[Rear]
[Front]
– 7 –
2. ADJUSTMENT OF CURRENT SUPPLIED TO TELEPHONE
The distan e between the TD-600 and telephone an be made greater by making swit h
positions of both SW1 and SW2 identi al to adjust the urrent to be supplied to the
telephone. See the table below.
The line loop resistan e is fa tory-preset to 0~1500
Positions of SW1/SW2
1
2
3
Line loop resistan e ( )
0~1500
1500~2000
2000 or more
[Rear]
[Front]
– 8 –
JUMPER WIRE CONNECTION (When using the EX-200 ex hange)
Referring to Table 1, hange settings of jumper wires JP1-JP3.
All jumpers are fa tory-preset to the EXES-6000' s settings.
EXES-6000
EX-200
Jumper installed
JP1
JP2
JP3
Jumper installed
Jumper not installed
Cut jumper
Cut jumper
Install jumper
[Rear]
[Front]
3.
Table 1
Ex hange
Jumper
– 9 –
4. POLARITY REVERSE SIGNAL CONTROL
When onne ting the telephone line terminal to equipment that must not re eive the polarity
reverse signal, install the jumper wire in pla e marked with JP4 in the figure.
Jumper JP4 is not fa tory-preset be ause the polarity reverse signal is set to transmit
from the CH1 or CH2 telephone line terminal.
[Rear]
[Front]
CALL OPERATIONS
(1 )Lift up the handset and onfirm that a dial tone is audible. Dial the desired station number
within 10 se onds.
(2)Repla e the handset when terminating the onversation.
(3)The inter om station's dial key
orresponds to dial key
of the pushphone.
[Example]
Inter om station
Pushphone
(All all paging)
(All all paging)
• Dialing must be ompleted within 10 se onds after lifting up the handset. If in omplete,
no dial signal an be transmitted to the ex hange even when the dial keys are pressed.
Thus, the pushphone annot be used for fun tions su h as all transfer, spee h message,
busy all ba k et . to dial during the onversation.
• When transmitting the DTMF signal during the onversation in onun tion with the TI-20
or TI-600 tie-line unit et ., do not press any button of pushphone. This will lead to
malfu tion of the ex hange.
– 10 –
INSTALLATION
Ra k mounting
Atta h supplied bra kets to the TD-600 to mount it in the ra k.
M5 Ra k mounting s rew
Fiber washer
Ra k mounting bra ket
M3 Binding head s rew
M3 Washer
Unit an not be built in the inside of EX-610/620 ex hanges.
Mount it using the optional CR-271N or CR-392N abinet ra k.
Desk-top appli ation
Rubber foot
Atta h supplied rubber feet to holes ( ø 2.5mm) on the bottom surfa e (four pla es).
– 11 –
SPECIFICATIONS
ACCESSORIES
Ra k mounting bra ket
Ra k mounting s rew
(M5x12 tapping s rew)
Fiber washer
Binding head s rew (M3x6)
M3 washer
Rubber foot
Installation manual
2
4
4
4
4
4
1
TOA Corporation
KOBE, JAPAN
133-06-171-00
Operating voltage
Current onsumption
Appli able telephone
Permissible line resistan e
Frequen y response
Max. output signal level
Line output DC voltage
Ringing tone
Line apa ity
Line onne tion
Installation method
Ambient temperature range
Dimensions
Finish
Weight
+ 24V DC (20V~28V)
250 mA
max.
DTMF type
2500
(loop)
300~3400 Hz
-10 dBm
-48V
75V,
16Hz
2 lines
S rew terminal
Desk top or ra k mounting
0°C~40°C ( 3 2
0
F~104
0
F)
432(483)(W)x44.5(H)x298(D) mm
(17.01(19. 02) x 1.75 x 11.73 in.)
Panel: metalli gold
Case: olored steel plate-dark grey (Munsell N3.0)
Ra k mounting bra ket: metalli gold
3.3kg (7.3lb.)
Please see the reverse side for English manual.
TD-600
EXES-6000
EX-600/610/620/630
EX-200
EXES-2000
CH1
CH2
CH2
CH2
CH1
CH1
– 3 –
TD-600
TD-600
– 4 –
TD-600
TD-600
– 5 –
TD-600
– 6 –
<CH 1 >
<CH2>
– 7 –
<CH2>
<CH1>
– 8 –

Other manuals for TD-600

1

Other Toa Intercom System manuals

Toa EXES-2000 User manual

Toa

Toa EXES-2000 User manual

Toa N-8540DS User manual

Toa

Toa N-8540DS User manual

Toa DT-E70 User manual

Toa

Toa DT-E70 User manual

Toa N-XC65-W User manual

Toa

Toa N-XC65-W User manual

Toa N-8020MS User manual

Toa

Toa N-8020MS User manual

Toa N-SP80MS1 User manual

Toa

Toa N-SP80MS1 User manual

Toa VS-900CO User manual

Toa

Toa VS-900CO User manual

Toa CP-66 User manual

Toa

Toa CP-66 User manual

Toa N-XC65-W User manual

Toa

Toa N-XC65-W User manual

Toa VS-900AF User manual

Toa

Toa VS-900AF User manual

Toa CP-66 System manual

Toa

Toa CP-66 System manual

Toa E-7000TB User manual

Toa

Toa E-7000TB User manual

Toa XRS-101SCS User manual

Toa

Toa XRS-101SCS User manual

Toa VS-900RS User manual

Toa

Toa VS-900RS User manual

Toa EXES-6000 User manual

Toa

Toa EXES-6000 User manual

Toa N-8540DS User manual

Toa

Toa N-8540DS User manual

Toa VS-900MF User guide

Toa

Toa VS-900MF User guide

Toa N-8050DS User manual

Toa

Toa N-8050DS User manual

Toa VS-900 User manual

Toa

Toa VS-900 User manual

Toa ZM-9003 User manual

Toa

Toa ZM-9003 User manual

Toa MS-900 User manual

Toa

Toa MS-900 User manual

Toa N-8000EX User manual

Toa

Toa N-8000EX User manual

Toa N-8031MS User manual

Toa

Toa N-8031MS User manual

Toa NF-2S User manual

Toa

Toa NF-2S User manual

Popular Intercom System manuals by other brands

SCS Sentinel AudioKit 32068 Installation and user manual

SCS Sentinel

SCS Sentinel AudioKit 32068 Installation and user manual

KOCOM KLP-100 User's manual for operation and installation

KOCOM

KOCOM KLP-100 User's manual for operation and installation

TCS ISW3330 user manual

TCS

TCS ISW3330 user manual

Bosma DR0001 Quick install guide

Bosma

Bosma DR0001 Quick install guide

ITS Telecom PanCam-C Installation and programming manual

ITS Telecom

ITS Telecom PanCam-C Installation and programming manual

Akuvox C317 Series manual

Akuvox

Akuvox C317 Series manual

Kenwood WD-K10 Series user manual

Kenwood

Kenwood WD-K10 Series user manual

Secure Home Busch SAS-Wx.11c quick guide

Secure Home

Secure Home Busch SAS-Wx.11c quick guide

Dahua VTH5221 series user manual

Dahua

Dahua VTH5221 series user manual

Microsound MF 400 instruction manual

Microsound

Microsound MF 400 instruction manual

ButterflyMX Key Locker installation guide

ButterflyMX

ButterflyMX Key Locker installation guide

Studio Technologies 371 user guide

Studio Technologies

Studio Technologies 371 user guide

Gianni Industries AD-425S Specification sheet

Gianni Industries

Gianni Industries AD-425S Specification sheet

Videx SENTRY Technical manual

Videx

Videx SENTRY Technical manual

LEGRAND 369210 manual

LEGRAND

LEGRAND 369210 manual

XtendLan DPM-571 user manual

XtendLan

XtendLan DPM-571 user manual

Comelit 6602W Technical manual

Comelit

Comelit 6602W Technical manual

LOXONE INTERCOM XL quick start guide

LOXONE

LOXONE INTERCOM XL quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.