Topcon OPUS A6 Generation 2 Eco Instruction Manual

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
1 Notes and Warnings
Attention!
This description is not a substitution for the
concerned product’s documentation. Please do
read the documentation including the manuals
carefully before dealing with this product. If the
safety instructions in the documentation are
not followed dangerous situation can occur that
can result in damages, injuries and/or death by
high voltage or wrong handling. In case you do
not have the correct documentation, you can
order it by contacting opus-
support@topcon.com. Only properly trained
personnel with the correct qualification is
allowed to handle the device.
Attention!
Do not open the housing to avoid danger to
high voltage. Before touching the electric
assemblies make sure that the electricity is
switched off completely. If the front pane is
broken the device needs to be taken out of
service due to risk of injury. If perceivable
damages on the device exist that can
compromise the functionality, it must be taken
out of service due to the danger of
malfunctions. These particularly include
damages to t he LCD display, damages to the
keyboard, damages that compromise the
protection level and damages to the encoder
knobs.
Please note:
All content is subject to change without notice.
Errors and omissions excepted.
Mounting and Handling
1. Do not use the cable as a handle to
carry the device.
2. Mounting in clean working environment
only.
3. Do not mount the device under the use
of violence because it can cause damage.
4. The device must be mounted by trained
personnel only into especially designed
and tested system.
5. The device may not be opened or
disassembled.
6. The device is to be cleaned with a moist
fuzz free cotton cloth. If necessary, a mild
cleaning agent may be used. Do nit use
acid or abrasive cleaning agents.
7. The device is to be stored in a cool and
dry environment and to be protected
against sunshine.
8. If the environmental temperature is
beneath 10°C the reaction time of the
display increases.
2 General Information
Order numbers
This documentation is valid for OPUS A6 Generation 2 order numbers as follows:
OPUSA6SN2CANB000
OPUSA6SN2CDSB000
OPUSA6SN2CWVB000
OPUS Projektor
●
CODESYS©
●
CODESYS©
mit WebVisu
●

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
Dimensions
Housing
Front cover: PC/ABS, colored light grey (RAL
7035) with black rubber frame.
Back cover: aluminum die cast, colored light
grey (RAL 7035)
Mounting
●Landscape or portrait
●Standalone
●In-dash

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
3 Display
4 Input Devices
Left Keypad
6 keys with tactile feedback
Multicolour LED backlight
Lifetime 1.000.000 actuations
Right Keypad
6 + 4 keys with tactile feedback
Multicolour LED backlight
Lifetime 1.000.000 actuations
Indicators and Sensors
Light sensor
1 Multicolor LED
2 Status LEDs
Encoder
Optical encoder with 16 mechanical detents
and push function
Lifetime: 1 milion cycles
Multicolour LED backlight
5 Electronics
Processor platform
CPU:
Freescale I.MX6®solo, 800 MHz
Mass storage:
2 GByte (minus space for OS &
application)
RAM:
512 MByte
RTC:
Buffered by gold cap
Buzzer
80 dB @ 1kHz in 1 m distance
Power supply
System supplied through terminal 30 (battery +,
see pinout) and 31 (battery -, see pinout).
Terminal 15 (ignition) to be used to switch on/off.
Operating voltage range: 9 …36 V DC.
Short circuit protection.
Over-voltage protection up to 48 V for max. 2 min.
Inverse polarity protection up to -48 V DC for max.
5 min.
Current consumption (without external load), max
Power Mode
Current
at 13,5 V DC
Current
At 27 V
On
≤1000 mA
≤600 mA
Low-power
Depending on configuration
Sleep
≤100 mA
≤65 mA
Off
≤2 mA
≤2 mA
Type:
TFT Color Graphic LCD with
LED backlight
Size:
7’’, 152 mm (W) x 91 mm (H)
Resolution:
800 x 480 px (WQVGA), 15:9
Colors:
16.7 Mio.
Brightness:
typ. 500 cd/m2
Contrast Ratio:
typ. 600:1

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
6 Interfaces
CAN Bus
2 x CAN-Interface according to ISO 11898,
CAN-specification 2.0 B active, up to 1 Mbit/s
(default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s, 1
Mbit/s)
RS232
1 x RS232-Interface
Type: EIA232 (only RXD, TXD, GND)
Speed: max. 115 Kbps
USB
Host 2.0
Main connector: 1 x High speed
Video Interface
Inputs:
1 x analog
Vss
1 V
Camera supply:
12 VDC
Max. current:
500 mA
Ethernet Interface
1 x 10/100 Mbit/s Base T
7 Connectors
Connectors
Main
Typo-AMP 1437288-6
Mating connector (customer)
Typo-AMP 3-1437290-7
Mating crimp contact (customer)
Typo-AMP 3-1447221-4
Dummy Plug (customer)
Typo-AMP 4-1437284-3
Video
M12 round connector, female,
5-pole, B-coded, acc. To EN
61076-2-101
Recommended mating connector type
according to IEC 61076-2-10: MM 005-Gx1-B
x) A, C, I, P, R or S-type
Ethernet
M12 round connector,
female, 4-pole, D-coded,
acc. To EN 61076-2-101
Recommended mating connector type according to
IEC 61076-2-10: MM 004-Gx1-D
x) A, C, I, P, R or S-type

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
8 Software
Operating System
Linux Kernel 3.0.0 or higher
Application Programming
•OPUS Projektor
•COESYS 3.x
•C/C++
9 Testing and Verification
CE-Compliance
EU Directive 2014/30/EU (EMC) according to
●EN 12895: Industrial Trucks –
Electromagnetic compatibility
●EN 13309: Construction machinery –
Electromagnetic compatibility of machines with
internal electrical power supply
●EN ISO 14982: Agricultural and forestry
machinery –Electromagnetic compatibility –
Test methods and acceptance criteria
E1 –Type approval
EU Directive ECE R 10.4
Protection Level (IP Code)
IP 65 and IP 66 according to ISO 20653: Road
Vehicles –Degrees of protection (IP-Code) –
Protection of electrical equipment against
foreign objects, water and access
Electrical
12 and 24V-Systems according to ISO 16750-
2: Road Vehicles –Environmental conditions
and testing for electrical and electronic
equipment –Electrical Loads
●ISO 15003: Agricultural Engineering –
Electrical and electronic equipment –Testing
resistance to environmental conditions
Mechanical
●ISO 16750-3: Road Vehicles –Environmental
condition and testing for electrical and electronic
equipment –Mechanical loads., Code L
●ISO 15003: Agricultural Engineering –Electrical
and electronic equipment –Testing resistance to
environmental conditions
●Mechanical Shock: Level 2
●Random Vibration: Level 2
●Sinusoidal Vibration: Level 2
Climate
●ISO 16750-4: Road Vehicles –Environmental
conditions and testing for electrical and electronic
equipment –Climatic Loads
●Operating Temperature Range: -30 …+ 65°C
●Storage Temperature Range: -40 …+85°C
●ISO 15003: Agricultural Engineering –Electrical
and electronic equipment –Testing resistance to
environmental conditions

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
10 Pinout
Main connector pinout
1
VCC
supply voltage +; terminal 30
2
Ignition Input
ignition input; terminal 15
3
GND
supply voltage -; terminal 31
4
CarGND
Car GND
5
n.c.
not connected
6
n.c.
not connected
7
n.c.
not connected
8
CAN1H
CAN 1 high
9
CAN1L
CAN 1 low
10
CAN2H
CAN 2 high
11
CAN2L
CAN 2 low
12
USB_VCC
USB +5V supply
13
USB_GND
USB supply GND
14
USB_D-
USB data -
15
USB_D+
USB data +
16
RS232 RxD
RS232 receive data
17
RS232 TxD
RS232 transmit data
18
RS232 GND
RS232 GND
19
n.c.
not connected
20
n.c.
not connected
21
n.c.
not connected
22
n.c.
not connected
23
SERV_EN
service enable
24
n.c.
not connected
25
n.c.
not connected
26
n.c.
not connected
View on rear side of the OPUS A3
OPUS displays in the industrial sector are only intended to use with cable length less than 30 meters.
Pin No.
Assignment
Description

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
Video connector pinout
Ethernet connector pinout
Round connector, 5 pins, M12
1
VidSig+
2
n.c.
3
Camera+
4
Camera-
5
VidSig GND
Round connector, 4 pins, M12
acc. to IEC 61076-2-101
1
VidSig+
2
n.c.
3
Camera+
4
Camera-
5
VidSig GND
Video connector, M12, female, 5 pins, b-coded,
View on rear side of the OPUS A3
Ethernet connector, M12, female, 4 pins, d-coded,
view on rear side of the OPUs A3
Recommended mating connector type according
to IEC 61076-2-10:
MM 005-Gx1-B
x) A, C, I, P, R or S-type
Recommended mating connector type according
to IEC 61076-2-10:
MM 004-Gx1-B
x) A, C, I, P, R or S-type

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
11 Accessories (not included)
Standalone mounting adaptor for RAM® mounting
system (OPUSA3ZBAH001)
Material
PC+ABS
Dimensions
74x84x42xmm (WxHxD)
Operating temperature
-30 …+ 75 °C
Storage temperature
-40 …+ 85 °C
Max mounting torque
2.5 ± 0.2 Nm
Mounting kit (RAM®Mount 1,5’’, adapter cover)
(OPUSBERM004)
1 x RAM®–101 U
1 x Adapter for RAM®mounting system
7 x cylinder head bolt M5x12 DIN 912

Industriestrasse 7 ▪65366 Geisenheim ▪Germany
www.topcon-electronics.de ▪dl-opus-info@topcon.com
In-Dash mounting frame (OPUSA3ZBEB002)
Material
PC+ABS
Dimensions
144x101x35 (WxHxD)
Operating temperature
-30 …+ 75 °C
Storage temperature
-40 …+ 85 °C
Max mounting torque
2.5 ± 0.2 Nm
Delivery includes highlighted parts only.
Please follow the instruction for in-dash mounting.
26 pin connector, contact pins, dummy plugs
(OPSVF26001)
This manual suits for next models
3
Table of contents
Popular Touchscreen manuals by other brands

ViewSonic
ViewSonic ViewBoard IFP50 Series quick start guide

Bosch
Bosch Control Air M Installation & operation manual

Acura Embedded
Acura Embedded AcuBrite 12 user manual

URC
URC Total Control TKP-8600 owner's manual

NETGEAR
NETGEAR HSS101 user manual

Tyco Electronics
Tyco Electronics Elo Entuitive Touchmonitor ET1925L Series user guide

Sam4s
Sam4s SPS-2000 Program reference manual

Elo TouchSystems
Elo TouchSystems 1002L user manual

QOLSYS
QOLSYS IQ PANEL installation manual

Technicolor
Technicolor TCA203 user guide

Panasonic
Panasonic TH-80LFB70E operating instructions

Elo TouchSystems
Elo TouchSystems SELF SERVICE STAND Assembly instructions