Models: RAS-137, 167SKV-E
Models: RAS-107SKV-E
1
Press FIX : Move the louver in
the desired vertical direction.
2
Press SWING: Swing the air
automatically and press again
to stop.
3
For horizontal direction, adjust
manually.

DANGER
•
Do not install, repair, open or remove the cover. It may expose you to
dangerous voltages. Ask the dealer or the specialist to do this.
•
Turning off the power supply will not prevent potential electric shock.
•
The appliance shall be installed in accordance with national wiring
regulation.
•
Means for disconnection from the supply having a contact separation
of at least 3 mm in all poles must be incorporated in the fixed wiring.

WARNING
•
Do not expose your body directly to cool air for a long time.
•
Do not insert your finger or any article into the air inlet/outlet.
•
When an abnormality (burning smell, etc.) occurs, stop the air
conditioner and disconnect the power supply or turn off the breaker.

CAUTION
•
Do not wash the unit with water. It may cause an electric shock.
•
Do not use this air conditioner for other purposes such as preserving
food, breeding animal, etc.
•
Do not step or put anything on the indoor/outdoor unit. It may cause
an injury or damage the unit.
•
Do not touch aluminium fin because it may cause an injury.
•
Before cleaning the unit, turn off the main switch or the circuit
breaker.
•
When the unit won’t be used for a long time, turn off the main switch
or the circuit breaker.
•
It is recommended that maintenance be performed by a specialist
when the unit has been operated for a long time.
PRECAUTIONS FOR SAFETY
INDOOR UNIT DISPLAY
 FILTER (Orange)
 PRE DEF (DE-FROST) (Orange)
 TIMER (Yellow)
 OPERATION (Green)
 RESET button
1
PREPARATION BEFORE USE
2
Preparing Filters
1. Open the air inlet grille and remove the air filters.
2. Attach the filters. (see detail in the accessory sheet)
Loading Batteries
1. Remove the cover. Insert 2 new
batteries (AAA type) following the
(+) and (–) positions.
2. Push RST : Reset the remote
control.
3. Place the cover back.
AIRFLOW DIRECTION
3
Note:
• Do not move the louver manually by others.
• The louver may move automatically positioning by operation mode.

 OPERATION (Green)
 TIMER/CLEANING (Yellow)
 RESET button
REMOTE CONTROL FUNCTION
4
 Infrared signal emitter
 Set louver button (FIX)
 Auto louver button (SWING)
 Mode select button (MODE)
 Reset button (RST)
 On timer button (ON)
 Off timer button (OFF)
 Reserve button (SET)
 Cancel button (CLR)
 Check button (CHK)
 ECO button (ECO)
 Fan speed button (FAN)
 Start/Stop button (START/STOP)
 Temperature button ( )
5
To automatically select cooling or fan only operation and control fan speed.
1. Press MODE : Select AUTO.
2. Press : Set the desired temperature.
The manufacture setting temperature is 24°C and available range of set
temperature is ±5°C.
COOLING / HEAT/AUTO FAN OPERATION
6
1. Press MODE: Select COOL, HEAT or AUTO FAN.
2. Press : Set the desired temperature.
COOL: Min 17oC, HEAT: Max 30oC, AUTO FAN :
No temperature indication
3. Press FAN : Select AUTO, QUIET, LOW , MED , HIGH .
DRY OPERATION
7
For dehumidification, a moderate cooling performance is controlled
automatically.
1. Press MODE : Select Dry.
2. Press : Set the desired temperature.
ECONOMICAL OPERATION
8
To automatically control room temperature, fan speed and operation mode
1. Press ECO in the AUTO and COOL operation: Start and stop the
operation.
2. Press MODE or FAN after stopping the operation.
Note:
• Under certain conditions, ECO mode may not provide adequate cooling
due to energy saving features.
TEMPORARY OPERATION
9
In case of the misplaced or discharged remote control
• Pressing the RESET button, the unit can start or
stop without using the remote control.
• Operation mode is set on
AUTOMATIC operation, preset
temperature is 24°C and fan
operation is automatic speed.










CLEANING
RESET TIMER OPERATION
TIMER OPERATION
10
Setting ON/OFF Timer
1. Press ON or OFF.
2. Press SET : Set the timer.
3. Press CLR : Cancel the timer.
4. Press START/STOP : Stop the air conditioner timer.
Note:
• If you do not press the SET, ON or OFF button for 30 seconds, the timer
setting is cancelled.


















AUTO RESTART OPERATION
11
To automatically restart the conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
To operate at super low fan speed for quiet operation (except in DRY mode)
Press FAN : Select QUIET operation.
Note: Under certain conditions, QUIET operation may not provide adequate
cooling or heating due to low sound features.
QUIET OPERATION
12
OPERATION AND PERFORMANCE
14
1. Three-minute protection feature: To prevent the unit from being activated
for 3 minutes when suddenly restarted or switched to ON.
2. Preheating operation: Warm up the unit for 5 minutes before the heating
operation starts.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released
into the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Consideration for accumulated snow: Select the position for outdoor unit
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
7. Some minor cracking sound may occur when unit operating. This
is normal because the cracking sound may be caused by expansion/
contraction of plastic.
Note: Item 2 to 6 for Heating model
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature Room
Temperature
137, 167SKV-E 107SKV-E
Heating -15°C ~ 24°C -10°C ~ 24°C Less than 28°C
Cooling -10°C ~ 46°C 15°C ~ 43°C 21°C ~ 32°C
Dry -10°C ~ 46°C 15°C ~ 43°C 17°C ~ 32°C
The unit does not operate. Cooling is abnormally low.
• The power main switch is turned
off.
• The circuit breaker is activated to
cut off the power supply.
• Stoppage of electric current
• ON timer is set.
• The filters are blocked with dust.
• The temperature has been set
improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or
DRY.
TROUBLESHOOTING (CHECK POINT)
15
REMOTE CONTROL A-B SELECTION
16
To separate using of remote control for each indoor unit in case of 2 air
conditioners are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold [CHK] button on the Remote Control by the tip of the
pencil. “00” will be shown on the display.
4. Press [MODE] during pushing [CHK]. “B” will show on the display and
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Note: 1. Repeat above step to
reset Remote Control to
be A.
2. Remote Control A has
not “A” display.
3. Default setting of
Remote Control from
factory is A.
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the filter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when
needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
MAINTENANCE
13
EN

Other manuals for RAS-107SKV Series

2

This manual suits for next models

5

Other Toshiba Air Conditioner manuals

Toshiba RAS-05, RAS-07 User manual

Toshiba

Toshiba RAS-05, RAS-07 User manual

Toshiba 18E2KVG-A User manual

Toshiba

Toshiba 18E2KVG-A User manual

Toshiba RAS-B05J2KVG-E User manual

Toshiba

Toshiba RAS-B05J2KVG-E User manual

Toshiba MMK-AP0074MH-TR User manual

Toshiba

Toshiba MMK-AP0074MH-TR User manual

Toshiba RAS-2M14U2AVG-E User manual

Toshiba

Toshiba RAS-2M14U2AVG-E User manual

Toshiba MML-AP0074NH-E User manual

Toshiba

Toshiba MML-AP0074NH-E User manual

Toshiba RAV-104 Series User manual

Toshiba

Toshiba RAV-104 Series User manual

Toshiba Carrier MMU-AP0074HPUL Product guide

Toshiba

Toshiba Carrier MMU-AP0074HPUL Product guide

Toshiba RAV-GP561ATW-E User manual

Toshiba

Toshiba RAV-GP561ATW-E User manual

Toshiba Q9 HVAC Instruction Manual

Toshiba

Toshiba Q9 HVAC Instruction Manual

Toshiba RAS-13G2KCVP-T User manual

Toshiba

Toshiba RAS-13G2KCVP-T User manual

Toshiba RAV-SM304MUT-E User manual

Toshiba

Toshiba RAV-SM304MUT-E User manual

Toshiba RAV-GM561UT-E User manual

Toshiba

Toshiba RAV-GM561UT-E User manual

Toshiba RAS-10N3KV-E User manual

Toshiba

Toshiba RAS-10N3KV-E User manual

Toshiba RBM-Y0611FU4PUL User manual

Toshiba

Toshiba RBM-Y0611FU4PUL User manual

Toshiba RAV-SM307KRTP-E User manual

Toshiba

Toshiba RAV-SM307KRTP-E User manual

Toshiba MMU-UP0071HP-UL User manual

Toshiba

Toshiba MMU-UP0071HP-UL User manual

Toshiba RAS-10JKCVP Series User manual

Toshiba

Toshiba RAS-10JKCVP Series User manual

Toshiba 16N3KVP Series User manual

Toshiba

Toshiba 16N3KVP Series User manual

Toshiba RAS-M10N4KCV User manual

Toshiba

Toshiba RAS-M10N4KCV User manual

Toshiba RAS-B10N4KVRG-E1 User manual

Toshiba

Toshiba RAS-B10N4KVRG-E1 User manual

Toshiba RBM-Y1124FE User manual

Toshiba

Toshiba RBM-Y1124FE User manual

Toshiba RAS-16N3AV2 Series User manual

Toshiba

Toshiba RAS-16N3AV2 Series User manual

Toshiba RAS-18GFHP-ES2 User manual

Toshiba

Toshiba RAS-18GFHP-ES2 User manual

Popular Air Conditioner manuals by other brands

Daikin R-410A Technical manual

Daikin

Daikin R-410A Technical manual

Be Cool BCP5AC2101F manual

Be Cool

Be Cool BCP5AC2101F manual

Honeywell HL10 Series user manual

Honeywell

Honeywell HL10 Series user manual

Fujitsu General ASHH30KMTB Service manual

Fujitsu

Fujitsu General ASHH30KMTB Service manual

Sears Kenmore P/N93SR-D02 owner's manual

Sears

Sears Kenmore P/N93SR-D02 owner's manual

Panasonic PZ2 Series operating instructions

Panasonic

Panasonic PZ2 Series operating instructions

LG LS-J0761CL Service manual

LG

LG LS-J0761CL Service manual

Dometic MCS T6 operating manual

Dometic

Dometic MCS T6 operating manual

Friedrich Chill CP18 Installation and operation manual

Friedrich

Friedrich Chill CP18 Installation and operation manual

Hisense 7K Use and Installation Instructions

Hisense

Hisense 7K Use and Installation Instructions

Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Airxcel

Airxcel Marvair ComPac II AVHDA90 Installation & operation manual

Gree GWHD(14)NK6OO(LC)(LH) Service manual

Gree

Gree GWHD(14)NK6OO(LC)(LH) Service manual

Amana PHB**C Service instructions

Amana

Amana PHB**C Service instructions

GREE ELECTRIC GWH09TA-S3DNA1C Service manual

GREE ELECTRIC

GREE ELECTRIC GWH09TA-S3DNA1C Service manual

Ravanson KR-8000 user manual

Ravanson

Ravanson KR-8000 user manual

Lennox FLEXY FX 025 Application guide

Lennox

Lennox FLEXY FX 025 Application guide

Hokkaido HKEI-HCNI 263 XR Service manual

Hokkaido

Hokkaido HKEI-HCNI 263 XR Service manual

Haier AS072AIAAA Operation manual

Haier

Haier AS072AIAAA Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.