-8 -
6 F 8 A 0 9 9 7
7.2.2 Setting and Calibration....................................................................................................................46
7.3Configuration Items Selection Table.............................................................................................................50
7.4 Password input..............................................................................................................................................52
8. Parameter Settings.................................................................................................................................................53
8.1 Parameter Setting Items ...............................................................................................................................53
8.2 Check/Change of Parameters.......................................................................................................................54
8.2.1 Menu Configuration Selection Screen.............................................................................................54
Function A: Detector Settings........................................................................................................................55
8.2.2 Exciting Current Value (Function A-1).............................................................................................55
8.2.3 Meter Size (Function A-2)...............................................................................................................56
8.2.4 Exciting Frequency (Function A-3)..................................................................................................58
8.2.5 Flow Direction Setting (Function A-4)..............................................................................................59
Function B: Display Settings.........................................................................................................................60
8.2.6 Display Setting (Function B-1, B-2).................................................................................................60
8.2.7 Custom Coefficient Setting (Function B-2)......................................................................................64
8.2.8 Custom Unit Setting (Function B-3).................................................................................................65
Function C: Range Settings..........................................................................................................................66
8.2.9 Span (Range) (Function C).............................................................................................................66
Function D: Filter Settings.............................................................................................................................73
8.2.10 Damping Constant (Function D-1)...................................................................................................73
8.2.11 Rate-Of-Change Limit and Control Limit Time (Function D-2)........................................................74
Function E: Low Cutoff Settings....................................................................................................................76
8.2.12 Low Cutoff (Function E-1)...............................................................................................................76
8.2.13 Display Low Cutoff (Function E-2)...................................................................................................77
Function F: Zero Point Setting.......................................................................................................................78
8.2.14 Still Water Zero Adjustment (Function F-1).....................................................................................78
8.2.15 Manual Zero Adjustment (Function F-2) .........................................................................................79
Function G: Current Output Setting...............................................................................................................80
8.2.16 4−20mA Alarm Output Setting (Function G-1)................................................................................80
8.2.17 Output Low Limit Setting (Function G-2).........................................................................................81
Function H: Digital Output Settings...............................................................................................................82
8.2.18 Digital Output (Function H)..............................................................................................................82
Function I: Digital Input Settings....................................................................................................................84
8.2.19 Digital Input (Function I)..................................................................................................................84
Function J: Count and Pulse Settings...........................................................................................................86
8.2.20 Count Rate (Pulse Rate), Pulse Width Setting Mode and Pulse Width (Function J).................86
Function K: Preset Settings...........................................................................................................................89
8.2.21 Preset Count (Function K-1)............................................................................................................89
8.2.22 Preset Mode (Function K-2)............................................................................................................91
Function L: High/Low Alarm Settings............................................................................................................92
Function M: High-High/Low-Low Alarm Settings...........................................................................................92
8.2.23 Flow Rate High/Low Alarm and High-High/Low-Low Alarm (Function L, Function M)............92
Function N: Self-diagnosis Function Settings................................................................................................94
8.2.24 Empty Pipe Alarm Setting (Function N-1).......................................................................................94
8.2.25 Self Diagnosis ON/OFF Setting (Function N-2)...............................................................................95
8.2.26 Converter Alarm (Function N-3)......................................................................................................96
Function O: Fixed Value Output Settings......................................................................................................97
8.2.27 Fixed Value Output (Function O-1).................................................................................................97
Function P: Other Settings 1.......................................................................................................................100
8.2.28 Password Setting (Function P-1)...................................................................................................100
8.2.29 LCD Adjustment (Function P-2)....................................................................................................104