SPECIFICATIONS
FUNCTION RANGE ACCURACY
DCA
100mV/A 10mA - 20A +/- (1.5% + 20mA)
10mV/A 100mA - 40A +/- (2% + 20mA)
40A - 60A +/- (4% + 20mA)
ACA
100mV/A 10mA - 10A +/- (2% + 20mA)
(40Hz to 1kHz)
+/- (4% + 30mA)
(1kHz to 10kHz)
+/- (8% + 30mA)
(10kHz to 20kHz)
10mV/A 100mA - 40A +/- (2% + 30mA)
(40Hz to 1kHz)
+/- (4% + 30mA)
(1kHz to 2kHz)
+/- (6% + 30mA)
(2kHz to 5kHz)
Operating Temperature 32 to 122 degrees F
Storage Temperature -4 to 158 degress F
Relative Humidity 0 to 80%
Max Conductor Size 9.0mm (0.35 inches)
Power Supply 9 Volt Battery
9
APPLICATION NOTES:
PARASITIC LOAD ON BATTERY
(KOEO- Key Off, Engine Off)
Please refer the figure on page 8
regarding the following notes:
1. Note the reading on the 133 is
-.012 This is becsuse we attached the
A254 to the negative (-) battery cable to
ensure you measure the entire parasitic
draw on the battery. Most new automo-
biles have multiple cables attached to the
positive post that does not allow you to
include all in your measurement.
2. Refering to the chart on page 5, a reading
of .012 DC volts with the A254 set on the
100mV/A range is actually 120mA
(milliamps).
3. Note that the 133 is set on the 2 DCV
range. This is the range the output of the
A254 is designed to use on the 120 and
133 meters. Use the 4 volt range on the
153, 163, 183 and 440.