Issued: SEPT. 25th, 2013 / Rev.: 0.0
INSTALLATION INSTRUCTIONS
TMM 24 Series AC/DC Switching Power Supply
Order Code *
Input Voltage
Range
Rated Output
Power
Output1
Output2
Recommended
circuit Breaker /
Fuse
TMM 24105 (C)
Nominal:
100 –240Vac
47 –440Hz
Operational:
85-264Vac
47 –440Hz
15W
5Vdc / 3000mA
-
?
TMM 24109 (C)
24W
9Vdc / 2666mA
-
TMM 24112 (C)
12Vdc / 2000mA
-
TMM 24115 (C)
15Vdc / 1600mA
-
TMM 24124 (C)
24Vdc / 1000mA
-
TMM 24212 (C)
+12Vdc / +1000mA
-12Vdc / -1000mA
TMM 24215 (C)
+15Vdc / +800mA
-15Vdc / -800mA
* Option C indicates the unit with chassis mount
Input Current:
@ Vin = 115Vac
@ Vin = 230Vac
TMM 24105 (C)
285mA
170mA
TMM 24xxx (C)
425mA
255mA
Operating temperature range:
Natural Air Convection Cooling (20LFM)
-40°C –+80°C
Over temperature protection:
Shutdown:
Automatic recovery:
at 90°C
at 67°C approx
Output power derating in respect
to ambient temperature:
Model Type
Start of derating
Power derating
TMM 24105 (C)
+60°C
2.5%/K
TMM 24xxx (C)
+60°C
3.75%/K
Storage temperature range / Humidity:
-40°C –+95°C / 95% rH max.
Over voltage protection (main output only):
120% of Vout typ.
Connections:
Input / Output terminal:
Screw type terminal: Wires 1.5mm2max.
Recommended tightening torque (Used Copper Conductors only,
60/75°C): 0.5 to 0.6Nm (4.4 to 5.3lb.in.)
Pin (TMM 24xxxC):
PCB mounting with solder pins
Internal Fuse:
T2A 250VAC Min.
Case Material:
Plastic Resin + Fiberglass
UL 94V-0 flammability rating
Installation:
1. The following end product enclosures are required; Mechanical, Fire
& Electrical in accordance to applicable safety standards.
Sihlbruggstrasse 111 CH-6340 Baar, Switzerland
Issued: SEPT. 25th, 2013 / Rev.: 0.0
Safety Instructions:
Before installation read these instructions carefully and
completely. This installation instruction cannot account for
every possible condition of installation, operation or
maintenance. Further information can be obtained from
your local distributor’s office or from the product datasheet,
which can be downloaded from our website:
http://www.tracopower.com.
The power supplies are constructed in accordance with the
safety requirements of IEC/EN60950-1 and UL60950-1, UL
508 and CSA C22.2 No 107.1-01. They fulfil the
requirements of the Low Voltage Directive (LVD) and
carries the CE-mark. They are UL and cUL approved in
accordance to ANSI/AAMI ES60601-1, UL60950-1, UL 508
and CSA C22.2 No107 1-01 (recognised).The equipment
has not been evaluated according to IEC60601-1-2. The
EMC assessment shall be conducted for the end system
configuration.
Before any installation, maintenance or modification work
ensure that the main switch is switched off and prevented
from being switched on again. Non-observance, touching
of any live components or improper handling of this power
supply can result in death, severe personal injury or
substantial property damage. Proper and safe operation is
dependent on proper storage, handling, installation and
operation.
While applying connections, no mechanical stress should
be applied to the printed circuit board and its surface
mounted components.
Compliance with the relevant national regulations must be
ensured. Before operation is started the following condi-
tions must be ensured:
Connection to mains supply in compliance with national
regulations.
Power supply and mains cables must be sufficiently
fused.
All output wires must be rated for the power supply
output current and must be connected with the correct
polarity.
Do not disconnect while circuit is alive.
Sufficient cooling must be ensured
The equipment for installation in a Pollution Degree 2
environment.
The classification of the equipment is: (For ANSI/AAMI
ES60601-1)
Class II
No applied parts
Not AP or APG type
Protection class IPX0
Not intended for use in the presence of flammability
anaesthetic mixture with air or with oxygen or
nitrous oxide
Intended for continuous operation
Never work on the power supply if power is supplied:
Risk of electric arcs and electrical shock, which can cause
death, severe personal injury or substantial property
damage.
Warning: Hazardous voltages and components storing a
very substantial amount of energy are present in this power
supply during normal operating conditions. Improper
handling may result in an electric shock or serious burns!
Do not open the power supply
Do not introduce any objects into the power supply. An
output voltage adjustment potentiometer (if existing)
may only be actuated using an insulated screwdriver.
Keep away from fire, water and chemicals.
The switching power supply is intended used for medical
electrical equipment. There are not parts in this equipment,
not suitable for direct patient contact! (ANSI/AAMI
ES60601-1)
Do not modify this equipment without authorization of the
manufacturer. (ANSI/AAMI ES60601-1)
Caution: Double Pole/Neutral Fusing
Do not open the power supply until at least 5 minutes after
it has been disconnected from the mains on all poles.
Installation Instructions
This power supply is designed for professional indoor
systems. In operation the power supply must not be
accessible. It may be installed and put into service by
qualified personnel only.
All required connections have to be carried out as
described in the table on the front side.
By use of stranded wires, all strands must be fastened in
the terminal blocks (potential danger of short circuits).
Do not cover any ventilation holes. Optimal cooling
performance must be ensured. Observe power derating
(see datasheet).
The internal fuse(s) may not be replaced by the user. If an
internal fuse has blown, the power supply has most
properly an internal defect and, for safety reasons, must be
shipped to the local distributor.
The correct mounting position for optimal cooling
performance must be observed. Observe power derating.
(see datasheet)
Recycling: The unit contains elements that are suitable for
recycling, and components that need special disposal. You
are therefore requested to make sure that the power supply
will be recycled environment friendly at the end of its
service life.

This manual suits for next models

6

Other TracoPower Power Supply manuals

TracoPower TXL 100-3.3S Service manual

TracoPower

TracoPower TXL 100-3.3S Service manual

TracoPower TEX 120-112 User manual

TracoPower

TracoPower TEX 120-112 User manual

TracoPower TSP SERIES User manual

TracoPower

TracoPower TSP SERIES User manual

TracoPower TSP SERIES User manual

TracoPower

TracoPower TSP SERIES User manual

Popular Power Supply manuals by other brands

Pulsar AWZ 820-PSU-S-12V/L-3.5A/9/FTA-TR-MC quick start guide

Pulsar

Pulsar AWZ 820-PSU-S-12V/L-3.5A/9/FTA-TR-MC quick start guide

EVGA SuperNOVA 650P2 PLATINUM Series manual

EVGA

EVGA SuperNOVA 650P2 PLATINUM Series manual

BEHLMAN PF1352 Series manual

BEHLMAN

BEHLMAN PF1352 Series manual

golmar FA-G2+ instructions

golmar

golmar FA-G2+ instructions

Clayton Power LPS II Series Manual and safety instructions

Clayton Power

Clayton Power LPS II Series Manual and safety instructions

National Instruments NI PS-15 user manual

National Instruments

National Instruments NI PS-15 user manual

Sensata Dimensions 24U15 owner's manual

Sensata

Sensata Dimensions 24U15 owner's manual

Puls DIMENSION CP10.248 instruction manual

Puls

Puls DIMENSION CP10.248 instruction manual

TDK-Lambda Genesys Series user manual

TDK-Lambda

TDK-Lambda Genesys Series user manual

Puls PIANO Series installation instructions

Puls

Puls PIANO Series installation instructions

LEAB CDR 12/24 V quick start guide

LEAB

LEAB CDR 12/24 V quick start guide

Bentel Security BXM24/25-U manual

Bentel Security

Bentel Security BXM24/25-U manual

Atten ST-1509 user manual

Atten

Atten ST-1509 user manual

Akyga AK-ND-02 user manual

Akyga

Akyga AK-ND-02 user manual

Sony IPELA SNTA-RP1 installation manual

Sony

Sony IPELA SNTA-RP1 installation manual

PeakTech P 1525 Operation manual

PeakTech

PeakTech P 1525 Operation manual

EKSMA OPTICS HV-200 manual

EKSMA OPTICS

EKSMA OPTICS HV-200 manual

HP E3633A user guide

HP

HP E3633A user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.