Trader ARCTIC OWL OWPIR360 User manual

OWPIR360 / OWPIR360BK
Infrared Motion Sensor
Indoor 360°
Manual
Specifications
Detection Range: 360°
Detection Distance: 3m max (<24°C)
Time-Delay / ‘Switch On’ Duration: Min. 10sec±3sec
Max. 7min±2min
Installing Height: 2.2m - 4m
Power Consumption: <0.9W
Power Sourcing: 220V/AC-240V/AC
Power Frequency: 50/60Hz
Working Temperature: -20 > +40°C
Ambient Light: <5-2000LUX (Adjustable)
Rated Load: 2000W (incandescent lamp)
1000W (energy-saving lamp)
Working Humidity: <93%RH
Detection Motion Speed: 0.6 - 1.5m/s
2
Welcome to the OWPIR360 indoor 360 degree infrared motion sensor!
This product features a high level of sensitivity, excellent performance and a practical size
for convenience and safe, easy installation. It utilises the infrared energy from humans as the
control-signal source and starts the load when one enters the detection field. It can identify
day and night automatically and is extremely easy to install.
FUNCTION:
• Identifies day and night automatically. Can be adjusted for ambient light according to
your desire: when turned to ‘+’ (day/bright light), it will work during the day and at night.
When turned to ‘-’ (night/darkness), it will only work under less than 10LUX when set to the
minimum. For adjustment instructions, please refer to the Test section.
• The ‘Switch On Duration’ is added to continually when the OWPIR360 receives additional
sensor signals following the first initiation (if a presence continues to be detected). It then
switches off after the ‘Switch On Duration’ completes its cycle and the triggering source is
removed.
• Switch On Duration: this can be set according to your desire. The minimum is 10±3sec; the
maximum is 7±2min.
MANUAL OVERRIDE:
When the power is initially turned ON, the fitting operates in AUTO mode. In this mode, the
sensor turns the light ON and OFF automatically.
The MANUAL OVERRIDE function means that the fitting can be put permanently ‘ON’. In this
mode, the PIR sensor is disabled and the light stays on.
• Setting Manual Override (MO)
The lamp must be on to initiate MO. Then turn the wall switch ‘OFF’ and ‘ON’ twice (with 2
second wait between each action).
Wall switch action: OFF > ON > OFF > ON
• To change back to ‘AUTO MODE’, turn the power ‘OFF’ and wait for 10 seconds, then turn it
back ‘ON’ again.
Wall switch action: OFF > Wait 10 Secs > ON
It is important to note that the wait time between switch actions is critical for this
to function correctly. This tolerance on timing is tight to reduce the potential of
nuisance triggering of this function.
It may take several attempts to get used to setting manual override.
A video explanation can be found here:
http://www.gsme.com.au/other/outdoor-sensor/arctic-owl
Or use QR code here:
3
INSTALLATION:
• Product must be installed by a licensed electrician.
• Turn off the power and isolate the mains.
• Mark out appropriate position in the ceiling (ensure it is at a suitable height) and drill a
63mm hole. Pull through the wiring to be connected, ensuring there are no obstructions in
the ceiling space.
• Remove the transparent plastic cover that is covering the terminals.
• Loosening the screws in the terminal, connect the Active to the L terminal, Neutral to the N
terminal and Power to the switched load into the A terminal and tighten all screws. See the
detail in Figure 1.
• Replace the transparent plastic terminal cover into the original position and secure.
• To assemble into the ceiling, fold the metal springs of the sensor upwards until they are in
the position shown in step 3 of Figure 1. Then position carefully into the hole in the ceiling,
ease the sensor up gradually and the springs will release and pull the sensor into place.
• After installation, the sensor can be connected to power and you can commence testing and
adjusting the settings by pulling down on springs from the ceiling to access time and lux.
FIGURE 1:
TEST:
• Turn the TIME knob clockwise to the minimum, turn the LUX knob clockwise to the
maximum ‘ ’ (day/bright light)
• Turn on the power, the sensor will switch on and warm-up, 30 sec later, the unit will be
entered into the functioning AUTO state.
• 5-10 seconds after the light goes out for the first time, the unit will start sensing, the load
connected should switch on if triggered.
• Turn LUX knob anticlockwise to the minimum ‘ ’ (night/darkness). The sensor should not
work after load switches off, provided the lux level in the room is higher than the level set
for the minimum.
Note: when testing in daylight, turn LUX knob to ‘ ’ (day/bright light) position,
otherwise the sensor lamp will not work!
• Adjust the timer setting to allow the load to stay on to the desired time and performance,
then replace the outer cover and Fresnel lens and confirm it is functioning correctly.
NOTE:
• Avoid installing it on or near moving objects.
• There shouldn’t be any obstruction or moving object in front of the detection window that
can affect detection and performance.
• Avoid installing it near air temperature alteration zones such as air conditioners, central
heating, air conditioning ducts, etc.
• For safety reasons do not tamper with the unit after installation, contact the installing
electrician.
TIPS FOR SOLVING INSTALLATION PROBLEMS:
• The load doesn’t work:
a. Please check the power and load connected is correct.
b. Check if the load is functioning.
c. Check if the LUX level that is set, corresponds to the ambient light.
• The sensitivity is poor:
a. Please check if there are obstructions in front of the detection window impacting the
signals.
b. Please check if the ambient temperature is too high.
c. Please check if the signal source is in the detection field for the sensor.
d. Please check if the installation height corresponds to the height shown in the instructions.
• The sensor cannot switch the load off automatically:
a. Check if there are continual signals in the detection field.
b. Check if the time delay is set to the longest possible.
c. Check if the power corresponds to the instructions.
d. Check if the temperature is changing near the sensor, such as air conditioning or central
heating etc.
e. Check if Manual Override has been initiated.
GSM Electrical (Australia) Pty Ltd, Level 2 142-144 Fullarton Road, Rose Park SA 5067
www.gsme.com.au // Phone: 1300 301 838 // Fax: 1300 301 778
5 Year Manufacturer’s Warranty
This product has been manufactured to the highest quality standards.
This product is warranted to the original purchaser and is not transferable.
The product is guaranteed to be free from defects in workmanship and parts for a period of 5 Years from the date of purchase. Defects
that occur within this warranty period, under normal use and care will be repaired, replaced or refunded. The benefits conferred by this
warranty are in addition to all other rights and remedies of the consumer under Commonwealth, State and Territory laws in relation to
the goods or services to which this warranty relates and Australian Consumer Law. Risk in regard to the product to be repaired shall at all
times remain with the Purchaser. The warranty is given on the condition that the product to which it applies is used for the purpose and in
the manner intended by its construction and for no other purposes whatsoever. GSM Electrical (Australia) Pty Ltd shall not be responsible
for damage of any kind, caused by accidents, power surges, electrical storm damage, incorrect power current, infestation (vermin or
insect), incorrect installation, incorrect electricity or plumbing installation, improper use of controls or failure to use the product in
accordance with the operating instructions, general misuse or abuse or from normal wear and tear. Any attempt by an unauthorised
person to repair or tamper with the equipment shall render the warranty null and void.
GSM Electrical (Australia) Pty Ltd’s liability under this warranty is limited to the replacement and/or repair of the defective parts within the
warranty period and does not extend to installation or removal of the product. Acceptance of liability by GSM Electrical (Australia) Pty Ltd
contained herein is to the exclusion of any other remedy whatsoever and howsoever arising in respect of any equipment to which it applies.

This manual suits for next models

1

Other Trader Security Sensor manuals

Trader ARCTIC OWL OWPIROD User manual

Trader

Trader ARCTIC OWL OWPIROD User manual

Trader ARCTIC OWL OWPIROD 180 User manual

Trader

Trader ARCTIC OWL OWPIROD 180 User manual

Trader SCORPION SCSPSENSORBK User manual

Trader

Trader SCORPION SCSPSENSORBK User manual

Popular Security Sensor manuals by other brands

teko Astra-517 ver.P user guide

teko

teko Astra-517 ver.P user guide

iRay Technology Mars1717XF Series user manual

iRay Technology

iRay Technology Mars1717XF Series user manual

Alarmtech GD 370 Installer manual

Alarmtech

Alarmtech GD 370 Installer manual

Vanderbilt ES 470 installation manual

Vanderbilt

Vanderbilt ES 470 installation manual

B.E.G. LUXOMAT PD4-M-2C-DUO Installation and operating instructions

B.E.G.

B.E.G. LUXOMAT PD4-M-2C-DUO Installation and operating instructions

SharpEye 40I user guide

SharpEye

SharpEye 40I user guide

Honeywell Home 5819S Installation and setup guide

Honeywell Home

Honeywell Home 5819S Installation and setup guide

Lince 1926BOBBY-T-AM/U Installation, operation and maintenance manual

Lince

Lince 1926BOBBY-T-AM/U Installation, operation and maintenance manual

Sunx SF4B instruction manual

Sunx

Sunx SF4B instruction manual

EINHELL TC-MD 50 Original operating instructions

EINHELL

EINHELL TC-MD 50 Original operating instructions

Emerson Rosemount 396P instruction manual

Emerson

Emerson Rosemount 396P instruction manual

Greenlee FI-100 instruction manual

Greenlee

Greenlee FI-100 instruction manual

Dragino LHT65N-E5 user manual

Dragino

Dragino LHT65N-E5 user manual

Alarmtech MC 340 2x4,7k instruction manual

Alarmtech

Alarmtech MC 340 2x4,7k instruction manual

Dudek ZEROGRAVITY user manual

Dudek

Dudek ZEROGRAVITY user manual

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

DoCash Lite D user manual

DoCash

DoCash Lite D user manual

brennenstuhl PIR 240 Directions for use

brennenstuhl

brennenstuhl PIR 240 Directions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.