IMPORTANT — This tool was designed to assist in properly charging a Link™ equipped Air Conditioning or Heat
Pump system with refrigerant by interfacing with a microprocessor that calculates the system subcooling.
NOTE: The installer must apply 24vac to the Red wire in the Outdoor units low voltage harness.
Specifications: R-410 A
24 Volt AC
Installer’s Guide
DO NOT CONNECT BACKWARDS.
HOSES WILL CONTAIN REFRIGERANT THAT
WILL BE UNDER PRESSURE.
NOTE: Device is not intended to charge without at least 50 PSIG of refrigerant pressure or temperatures below
65°F. To be used in cooling mode only.
BAYCAKT002AA SmartCharge™Tool
18-HH37D1-1B-EN
Figure 1: SmartCharge™Tool
Installation Instructions:
Refer to Figure 2 for the installation of
SmartCharge™Tool.
1. Attach a refrigerant hose from a refrigerant
bottle to the inlet side of the SmartCharge™
tool.
2. Open refrigerant bottle to pressurize inlet hose.
Purge hose by loosening inlet hose slightly at
SmartCharge™inlet connection. Tighten when
purge is complete.
3. Attach a refrigerant hose from the
SmartCharge™tool outlet to the Vapor line
service port. Unscrew refrigerant hose slightly
at the SmartCharge™outlet connection to
purge outlet hose. Tighten when purge is
complete.
4. Connect the interface cable from the
SmartCharge™tool to the IVSC at terminals T1
& T2 “Charge Solenoid” location.
5. Open the Diagnostics Mobile app and connect
to the system. Choose “Test Modes”. Select
SmartCharge™from the top banner.
6. Diagnostics Mobile app will show a status.
7. When the SmartCharge™procedure is
completed, close off refrigerant cylinder and
carefully disconnect hoses.