Operation
LED Indicators
Use the status LEDs to monitor the media converter operation in the network.
FL Flashing = The media converter is connected to external power.
On = The 10Base-FL (fiber) link has been established.
TBT Flashing = The media converter is connected to external power.
On = The 10Base-T (copper) link has been established.
E-TBT-FRL-NLP-01 / E-TBT-FRL-N-01
424-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
TX 10Base-FL RX
10Base-T
LINK
FL TBT
FL TBT
10Base-T
LINK
FL TBT
FL TBT
TX 10Base-FL RX
E-TBT-FRL-NLP-01
E-TBT-FRL-N-01
Cable Specifications
Fiber Cable
62.5/125 µm (recommended); bit error rate: <10-9
E-TBT-FRL-NLP-01
E-TBT-FRL-N-01 850 nm multimode
Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm
Link Budget 13.5 dB
E-TBT-FRL-NLP-01(SC)
E-TBT-FRL-N-01(SC) 850 nm multimode
Fiber-optic Transmitter Power: min: -16.0 dBm max: -10.0 dBm
Fiber-optic Receiver Sensitivity: min: -29.5 dBm max: -7.2 dBm
Link Budget 14.5 dB
The fiber optic transmitters on this device meet Class I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.
CAUTION:Visible and invisible laser radiation when open.Do not stare
into beam or view directly with optical instruments.
CAUTION:Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation
exposure.
5
Cable Specifications -- Continued
Copper Cable
Category 3: (Minimum requirement)
Gauge 24 to 22 AWG
Attenuation 11.5 dB/100m @ 5-10 MHz
Category 5: (Recommended)
Gauge 24 to 22 AWG
Attenuation 22.0 dB /100m @ 100 MHz
• Either straight-through twisted-pair cable may be used.
• Shielded (STP) or unshielded(UTP)twisted-pair may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out:Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1
2
3
6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1
2
3
6
1
2
3
6
1
2
3
6
Technical Specifications
For use with Transition Networks Model E-TBT-FRL-NLP-01 or equivalent
Standards: IEEE 802.3™
Data Rate: 10 Mb/s
Dimensions:(-NLP-01) 3.154 x 5.208 x 0.932”(80 x 134 x 24mm)
(-N-01) 4.762 x 5.208 x 0.932”(121 x 134 x 24mm)
Weight: 3 oz.(91g)(approximate)
Power Consumption: <450 mA
MTBF 1,203,000 hours (MIL217F2 V5.0) (MIL-HDBK-
217F) 3,222,000 hours (Bellcore7 V5.0)
Environment: Operating Temp*: 0 to 50°C (32 to 122°F )
Storage Temp: -25 to 85°C (-13 to 185°F )
Humidity: 10 to 90%, non condensing
Altitude: 0 to 10,000 feet
Warranty: Lifetime
*Manufacturer’s rated ambient temperature:Tmra range for this slide-in-
module depends on the physical characteristics and the installation
configuration of the file server or PC workstation in which this slide-in-
module will be installed.
Product is certified by the manufacturer to comply with DHHS Rule
21/CFR, Subchapter J applicable at the date of manufacture.