SUPPLY VOLTAGE
• 12 to 30Vdc
• Polarity Protected
Note: For use in Class 2 Circuits
CURRENT REQUIREMENTS
• 70mA @ 12Vdc, 35mA @ 30Vdc
DIGITAL OUTPUTS
• (1) NPN and/or (1) PNP (depending on
model) open collector output 150mA
Max; <2V Residual Voltage
• All outputs are continuously short circuit
protected
REMOTE AUTOSET INPUT
• Active high (PNP) or active low (NPN),
depending on model (1mA)
Note: Input not available on “L” models
DIAGNOSTIC INDICATORS
• Green LED AUTOSET Indicator-
Illuminates when sensor is powered
"ON"; flashes upon AUTOSET
adjustment
• Red LED Output Indicator– Illuminates
when the sensor’s output transistors are
“ON”.
Note: If output LED flashes on power
up, a short circuit condition exists.
PUSH BUTTON CONTROL
• Two (2) push button controls
• AUTOSET (for Gap AUTOSET)
• LT/DK (toggles between light on or dark
on)
• Manual threshold adjustment
HYSTERESIS
• Dynamic – adjusted by AUTOSET
RESPONSE TIME
• 225µs
REPEATABILITY
• 75µs
AMBIENT TEMPERATURE
• 4°C to 50°C (39°F to 122°F)
RUGGED CONSTRUCTION
• Chemical resistant, high impact
Aluminum housing
• Conforms to heavy industry grade CE
requirements
• Waterproof ratings: IP65*
*Presence of water on transducers will
prevent sensor from functioning. Full
functionality will be restored once
transducers are dry.
CONNECTIONS
• 4-Wire 6.5ft cable (2.0m)
• 4-Pin M12
• 4-Pin M8 connector
Specifications
RoHS Compliant
Product subject to change without notice
Connections and Dimensions CLS-2 Smaller Clear Label Sensor
www.ttco.com • 800-237-0946 070-0690, Rev. 1