Tribe MINIVERSAPAR User manual

USER MANUAL
MANUALE UTENTE
MINIVERSAPAR
EN - IT
PARLED ZOOM

All rights reserved by Music & Lights S.r.l. No part of this instruction manual may be
reproduced in any form or by any means for any commercial use.
In order to improve the quality of products, Music&Lights S.r.l. reserves the right to modify the
characteristics stated in this instruction manual at any time and without prior notice.
All revisions and updates are available in the ‘manuals’ section on site www.musiclights.it
REV.001-09/17

1
MINIVERSAPAR
Packing content • MINIVERSAPAR
• Mount bracket (2 pc.)
• Power cable
• User manual
TABLE OF CONTENTS Safety
General instructions
Warnings and installation precautions
1 Introduction
1. 1 Description
1. 2 Technical specications
1. 3 Operating elements and connections
2 Installation
2. 1 Mounting
3 Functions and settings
3. 1 Operation
3. 2 Basic
3. 3 Menu structure
3. 4 Auto show
3. 5 Static mode
3. 6 Manual mode
3. 7 Master/Slave mode
3. 8 Linking
3. 9 DMX mode
3. 10 DMX addressing
3. 11 Connection of the DMX line
3. 12 Construction of the DMX termination
3. 13 DMX control
3. 14 Dimmer
3. 15 Back light
3. 16 Fixture information
3. 17 LED frequency
3. 18 Temperature
3. 19 Fan mode
3. 20 White balance
4 Maintenance
4. 1 Maintenance and cleaning the unit
4. 2 Fuse replacement
4. 3 Trouble shooting
2
2
3
3
5
6
7
7
8
9
9
10
10
10
10
10
12
12
13
14
14
14
14
14
15
15
16
16
16

MINIVERSAPAR
2
SAFETY
General instruction
• The products referred to in this manual conform to the European Community Directives and are there-
fore marked with .
• The unit is supplied with hazardous network voltage (230V~). Leave servicing to skilled personnel only.
Never make any modications on the unit not described in this instruction manual, otherwise you will
risk an electric shock.
• Connection must be made to a power supply system tted with ecient earthing (Class I appliance ac-
cording to standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the units
from indirect contact and/or shorting to earth by using appropriately sized residual current devices.
• The connection to the main network of electric distribution must be carried out by a qualied electrical
installer. Check that the main frequency and voltage correspond to those for which the unit is designed
as given on the electrical data label.
• This unit is not for home use, only professional applications.
• Never use the xture under the following conditions:
- in places subject to vibrations or bumps;
- in places with a temperature of over 40 °C.
• Make certain that no inammable liquids, water or metal objects enter the xture.
• Do not dismantle or modify the xture.
• All work must always be carried out by qualied technical personnel. Contact the nearest sales point for
an inspection or contact the manufacturer directly.
• If the unit is to be put out of operation denitively, take it to a local recycling
plant for a disposal which is not harmful to the environment.
Warnings and installation precautions
• If this device will be operated in any way dierent to the one described in this manual, it may suer
damage and the guarantee becomes void. Furthermore, any other operation may lead to dangers like
short circuit, burns, electric shock, etc.
• Before starting any maintenance work or cleaning the projector, cut o power from the main supply.
• Always additionally secure the projector with the safety rope.When carrying out any work, always com-
ply scrupulously with all the regulations (particularly regarding safety) currently in force in the country
in which the xture’s being used.
• Install the xture in a well ventilated place.
• Keep any inammable material at a safe distance from the xture.
• Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent
that their eectiveness is impaired.
• The lamp (LED) shall be changed if it has become damaged or thermally deformed.
• Never look directly at the light beam. Please note that fast changes in lighting, e. g. ashing light, may
trigger epileptic seizures in photosensitive persons or persons with epilepsy.
• Do not touch the product’s housing when operating because it may be very hot.
WARNING! Before carrying out any operations with the unit, carefully read this instruction
manual and keep it with cure for future reference. It contains important information about
the installation, usage and maintenance of the unit.

3
MINIVERSAPAR
- 1 - INTRODUCTION
1.1 DESCRIPTION
MINIVERSAPAR is a compact indoor LED zoom PAR designed for rental companies. The multi-purpose con-
cept combining high brightness, wide zoom range and advanced colour mixing truly makes this a unique
xture. MINIVERSAPAR is equipped with 10°-40° unrivalled zoom range, high eciency, perfect chromatic
uniformity, HD dimming technology and totally silent operation.
1.2 TECHNICAL SPECIFICATIONS
LIGHT SOURCE
• Source: 7x10W RGBW LEDs
• Luminous ux: (10°) 1012lm (40°) 1335lm
• Lux: (10°) 4415 lux, (40°) 378lux @3m
• Source life expectancy: >50.000 h
OPTICS
• Zoom: 10 °- 40° motorised linear zoom
• Lens type: honeycomb gapless plano-convex optics
COLOUR SYSTEM
• Colour mixing: RGBW/FC
• White presets: 2800-10’000K
• Colour wheel: virtual colour wheel with presets
• Macros: several pre-build pixel macros with adjustable speed
DYNAMIC EFFECTS
• Static colour mode: selection of static colour
• Manual colour mode: manual adjustment of colour
• Auto mode: built-in programs with execution speed adjustment
• Sound mode: music activation through internal microphone and sensitivity control
BODY
• Body: sturdy die-cast aluminium body conceived for long-time durability
• Body colour: black
CONTROL
• Protocols: DMX512
• DMX channels: 5/7/10channel
• Display: 4-Chars display
• Firmware upgrade: yes, via USB-DMX interface (UPBOX1) not included
• Master/Slave: for synchronized operation of more units linked in a chain
ELECTRONICS
• Dimmer: linear 0~100% electronic dimmer
• Dimmer curves: dierent dimming curves available
• Strobe / shutter: 1/28 Hz, electronic
• Operating temperature: -10° ~ +40°
• Flicker: icker free operation
ELECTRICAL
• Power supply: 100-240V – 50/60Hz
• Power consumption (at 230V): 69,2W
• Power consumption (at 120V): 70W
• Output (at 230V): 54 units on a single power line
• Output (at 120V): 11 units on a single power line

MINIVERSAPAR
4
223235
301
PHYSICAL
• Cooling: forced air with low noise fan
• Data: USB port for USB WIFI transmitter (optional)
• Signal connection: XLR 3p+5p IN/OUT connectors
• Power connection: Seetronic powerCON IN/OUT connectors
• IP rating: 30 with a protective vent to prevent condensation, dust, compensate pressure
• Dimensions (WxHxD): 235x156x301mm
• Weight: 3.7kg
Fig.1Technical drawing

5
MINIVERSAPAR
1.3 OPERATING ELEMENTS AND CONNECTIONS
1. SCREW for the mounting bracket.
2. MOUNTING BRACKET.
3. Universal Serial Bus (USB)
4. DMX OUT (3-pole XLR):
1= ground, 2 = DMX -, 3 = DMX +.
5. CONTROL PANEL with display and 4 button
used to access the control panel functions
and manage them.
6. DMX IN (5-pole XLR):
1 = ground, 2 = DMX-, 3 = DMX+, 4 N/C, 5 N/C
7. DMX OUT (5-pole XLR):
1 = ground, 2 = DMX-, 3 = DMX+, 4 N/C, 5 N/C
Rear panel Fig.2
8. DMX IN (3-pole XLR): 1 = ground, 2 = DMX -,
3 = DMX +.
9. MAIN FUSE HOLDER: replace a burnt-out fuse
by one of the same type only (T1A/250V).
10. POWER IN (PowerCON IN): for connection to a
socket (100-240V~/50-60Hz) via the supplied
mains cable.
11. POWER OUT: connect to supply power to the
next unit.
12. SAFETY RING to attach safety cable.
7
5
10 11
9 12
4 6
8
1 3
2

MINIVERSAPAR
6
- 2 - INSTALLATION
2.1 MOUNTING
MINIVERSAPAR may be set up on a solid and even surface. The unit can also be mounted upside down to a
cross arm. For xing, stable mounting clips are required. The mounting place must be of sucient stability
and be able to support a weight of 10 times of the unit’s weight.
When carrying out any installation, always comply scrupulously with all the regulations (particularly re-
garding safety) currently in force in the country in which the xture’s being used.
• Install the projector at a suitable location by means of the mounting bracket (1).
• Always additionally secure the projector with the safety rope from falling down. For this purpose, fas-
ten the safety rope at a suitable position so that the maximum fall of the projector will be 20 cm.
• Adjust the projector and use the screw to slightly release or tighten the locking mechanism of the
bracket if is necessary (2).
Fig.3
1
2

7
MINIVERSAPAR
- 3 - FUNCTIONS AND SETTINGS
3.1 OPERATION
Connect the supplied main cable to a socket (100-240V~/50-60Hz). Then the unit is ready for operation
and can be operated via a DMX controller or it independently performs its show program in succession.
To switch o, disconnect the mains plug from the socket. For a more convenient operation it is recom-
mended to connect the unit to a socket which can be switched on and o via a light switch.
3.2 BASIC
Access control panel functions using the four panel buttons located directly underneath the black OLED
display (g.4).
Fig.4 - Functions of the buttons
MENU UP DOWN ENTER
Used to access the menu or
to return a previous menu
option
Navigates downwards through
the menu list and increases
the numeric value when in a
function
Navigates upwards through
the menu list and decreases
the numeric value when in
a function
Used to select and store the
current menu or conrm the
current function value or
option within a menu
MENU UP DOWN ENTER

MINIVERSAPAR
8
3.3 MENU STRUCTURE
MENU
15 CH ð1 - 512
26 CH 1 - 512
311 CH 1 - 512
4COLOR ðC 1
C 2
C 3
C 4
C 5
C 6
C 7
C 8
C 9
C 10
C 11
C 12
C 13
C 14
C 15
5ZOOM ðZoom (0-255)
6PROGRAMS ðP 1
P 2
P 3
P 4
7SPEED ðS (1 - 100)
8SOUND ðSnd 1
Snd 2
9SENS ðU (1 - 100)
10 UðR (0 - 255)
G (0 - 255)
B (0 - 255)
W (0 - 255)
11 DIMMER MODE ðO
Dimmer 1
Dimmer 2
Dimmer 3
12 TEMP ð65°

9
MINIVERSAPAR
. . . . . . . . . . . .
DMX512 Controller
DMX Address: 33 DMX Address: 48DMX Address: 38 DMX Address: 43
Fig.5 - Example 5 DMX channels conguration
Number of
DMX channels
Start address
(example)
DMX Address
occupied
Next possible start
address for unit No. 1
Next possible start
address for unit No. 2
Next possible start
address for unit No. 3
5 33 33-37 38 43 48
3. 4 LINKING
1. Connect the DMX OUT of the master unit via 3/5-pole XLR cable to the DMX IN of the rst slave unit.
2. Connect the DMX OUT of the rst slave unit to the DMX IN of the second slave unit, etc. until all units
are connected in a chain.
3. 5 DMX MODE
• Press the button MENU so many times until shows 5 Ch, 6 Ch or 11 Ch and press the button ENTER to
conrm.
• Press the button UP/DOWN to select the desired DMX address 001 - 512. Press and hold to scroll quickly.
Press ENTER button to store.
• Press the MENU button to go back or to meet the waiting time to exit the setup menu.
The tables on page 14 indicate the operating mode and DMX value. MINIVERSAPAR is equipped with 3/5-
pole XLR connections.
3. 6 DMX ADDRESSING
To able to operate the MINIVERSAPAR with a light controller, adjust the DMX start address for the rst a
DMX channel. If e. g. address 33 on the controller is provided for controlling the function of the rst DMX
channel, adjust the start address 33 on the MINIVERSAPAR. The other functions of the light eect panel are
then automatically assigned to the following addresses.
An example with the start address 33 is shown below:

MINIVERSAPAR
10
3. 7 COLOR
If no DMX control signal is present at the DMX INPUT, the unit independently runs through its show pro-
gramme provided that the blackout mode is switched o:
• Press the button MENU so many times until the display shows Color, then press the button ENTER.
• Press the button UP/DOWN to switch between the show C 1, ... , C 15. The unit will operate in show mode.
• Press the button ENTER to save the setting.
3. 8 AUTO SHOW
This xture has a built-in automatic program. To access this, please see the below instructions:
• Press the button MENU so many times until shows P-- , then press the button ENTER.
• Using UP/DOWN button, select one of the programs P1 - P4.
• Press the button ENTER to conrm.
• Press the button MENU until S-- appears on the display.
• Use the button UP/DOWN to select the auto programs speed S001 - S100 (slow-fast).
• Press the button ENTER save the setting.
3. 9 SOUND MODE
In music mode, via its integrated microphone, the unit can be controlled by music with a clear rhythm in
the bass range. If the music control should not work optimally, increase the volume or reduce the distance
between the sound source and the light eect unit.
• Press the button MENU so many times until the display shows Snd.
• Using UP/DOWN button, select one of the modes Snd1 or Snd2.
• Press the button ENTER to conrm.
• You can set the microphone sensitivity pressing the button MENU so many times until the display show
Sens
• Using the button UP/DOWN, select the desired value sensitivity (slow-fast) u0 - u100.
• Press the button ENTER to conrm.
3. 10 MANUAL COLOR
This mode allows to adjust the color (uv).
• Press the button MENU so many times until the display shows U-- , then press the button ENTER.
• Press the button ENTER to conrm.
• Using UP/DOWN button, select the desired color value 000 - 255.
• Press ENTER button to continue to the next color R, G, B, W.
• Continue until the desired color is obtained.
• Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3. 11 DIMMER
• Enter in Dimmer mode to select specic dimming curve, press the button MENU so many times until
shows dIM, and press the button ENTER to conrm.
• Press the button UP/DOWN to select OFF - dIM1 - dIM2 - dIM3.
• Press ENTER button to store.
• Press the MENU button to go back or to meet the waiting time to exit the setup menu.
3. 12 UNIT TEMPERATURE
Through the TEMP function you can display the temperature of the projector.
• Press the MENU button so many times until the display shows TEMP, then press the button ENTER.

11
MINIVERSAPAR
Fig.6
Fig.7
3.11 CONNECTION OF THE DMX LINE
DMX connection employs standard XLR connectors. Use shielded pair-twisted cables with 120Ω imped-
ance and low capacity.
The following diagram shows the connection mode:
ATTENTION
The screened parts of the cable (sleeve) must never be connected to the system’s earth, as this would
cause faulty xture and controller operation.
Over long runs can be necessary to insert a DMX level matching amplier.
For those connections the use of balanced microphone cable is not recommended because it cannot
transmit control DMX data reliably.
• Connect the controller DMX input to the DMX output of the rst unit.
• Connect the DMX output to the DMX input of the following unit. Connect again the output to the input
of the following unit until all the units are connected in chain.
• When the signal cable has to run longer distance is recommended to insert a DMX termination on the
last unit.
3.12 CONSTRUCTION OF THE DMX TERMINATION
The termination avoids the risk of DMX 512 signals being reected back along the cable when they reach-
es the end of the line: under certain conditions and with certain cable lengths, this could cause them to
cancel the original signals.
The termination is prepared by soldering a 120Ω 1/4 W resistor between pins 2 and 3 of the 5-pin male XLR
connector, as shown in gure.
DMX - OUTPUT
XLR socket
DMX - INPUT
XLR plug
Pin1 : GND - Shield
Pin2 : - Negative
Pin3 : + Positive
Pin4 : N/C
Pin5 : N/C
Example:
3 pin XLR connector

MINIVERSAPAR
12
3.13 DMX CONTROL
5 CANALI
MODE FUNCTION DMX
Value
5 Ch
1RED
0~100% 000 - 255
2GREEN
0~100% 000 - 255
3BLUE
0~100% 000 - 255
4WHITE
0~100% 000 - 255
5ZOOM
0~100% 000 - 255
11 CANALI
MODE FUNCTION DMX
Value
11 Ch
1DIMMER
0~100% 000 - 255
2RED
0~100% 000 - 255
3GREEN
0~100% 000 - 255
4BLUE
0~100% 000 - 255
5WHITE
0~100% 000 - 255
6
COLOR
No Function
Color Macros
000 - 015
016 - 255
7
STROBE
No Function
Slow to fast
000 - 010
011 - 255
8
PROGRAMS
No Function
0-100%
100%-0
100% -0-100%
Colors Fade
4Colors snap
15Colors snap
Sound Control
000 - 031
032 - 063
064 - 095
096 - 127
128 - 159
160 - 191
192 - 223
224 - 255
9
PROGRAMS SPEED
Speed slow to fast 000 - 255
SOUND SENSITIVITY
Sound sensitivity OFF
Control the sound sensitivity
000 - 010
011 - 255
10
DIMMER MODE
Preset dimmer speed from display menu
Dimmer speed mode o
Dimmer speed mode1 (fast speed)
Dimmer speed mode2 (middle speed)
Dimmer speed mode3 (slow speed)
000 - 051
052 - 101
102 - 152
153 - 203
204 - 255
11 ZOOM
0~100% 000 - 255
6 CANALI
MODE FUNCTION DMX
Value
6 Ch
1DIMMER
0~100% 000 - 255
2RED
0~100% 000 - 255
3GREEN
0~100% 000 - 255
4BLUE
0~100% 000 - 255
5WHITE
0~100% 000 - 255
6
STROBE
No Function
Slow to fast
000 - 010
011 - 255

13
MINIVERSAPAR
- 4 - MAINTENANCE
4.1 MAINTENANCE AND CLEANING THE UNIT
• Make sure the area below the installation place is free from unwanted persons during setup.
• Switch o the unit, unplug the main cable and wait until the unit has cooled down.
• All screws used for installing the device and any of its parts should be tightly fastened and should not
be corroded.
• Housings, xations and installation spots (ceiling, trusses, suspensions) should be totally free from any
deformation.
• The main cables must be in impeccable condition and should be replaced immediately even when a
small problem is detected.
• It is recommended to clean the front at regular intervals, from impurities caused by dust, smoke, or
other particles to ensure that the light is radiated at maximum brightness. For cleaning, disconnect the
main plug from the socket. Use a soft, clean cloth moistened with a mild detergent. Then carefully wipe
the part dry. For cleaning other housing parts use only a soft, clean cloth. Never use a liquid, it might
penetrate the unit and cause damage to it.
4.2 FUSE REPLACEMENT
1. Remove the safety cap by a screwdriver.
2. Replace the blown fuse with a fuse of the exact same type and rating (T2A/250V).
3. Install the safety cap, and reconnect power.
4.3 TROUBLESHOOTING Fig.8
Problems Possible causes Checks and remedies
Fixture does not light up
• No mains supply
• Dimmer fader set to 0
• All color faders set to 0
• Faulty LED
• Faulty LED board
• Check the power supply voltage
• Increase the value of the dimmer channels
• Increase the value of the color channels
• Replace the LED board
• Replace the LED board
General low light intensity • Dirty lens assembly • Clean the xture regularly
Fixture does not power up
• No power
• Loose or damaged power cord
• Faulty internal power supply
• Check for power on power outlet
• Check power cord
• Replace internal power supply
Fixture does not respond to DMX
• Wrong DMX addressing
• Damaged DMX cables
• Bouncing signals
• Check control panel and unit addressing
• Check DMX cables
• Install terminator as suggested
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.

REV.001-09/17
Music & Lights S.r.l. si riserva ogni diritto di elaborazione in qualsiasi forma delle presenti istruzioni per l’uso.
La riproduzione - anche parziale - per propri scopi commerciali è vietata.
Al ne di migliorare la qualità dei prodotti, la Music&Lights S.r.l. si riserva la facoltà di modicare, in
qualunque momento e senza preavviso, le speciche menzionate nel presente manuale di istruzioni.
Tutte le revisioni e gli aggiornamenti sono disponibili nella sezione 'Manuali' sul sito www.musiclights.it

3
MINIVERSAPAR
• MINIVERSAPAR
• Staa di ssaggio (2pz.)
• Cavo di alimentazione
• Manuale utente
Contenuto dell'imballo:
INDICE Sicurezza
Avvertenze generali
Attenzioni e precauzioni per l’installazione
1 Introduzione
1. 1 Descrizione
1. 2 Speciche tecniche
1. 3 Elementi di comando e di collegamento
2 Installazione
2. 1 Montaggio
3 Funzioni e impostazioni
3. 1 Funzionamento
3. 2 Impostazione base
3. 3 Struttura menu
3. 4 Modalità automatica
3. 5 Modalità statica
3. 6 Modalità manuale
3. 7 Modalità Master/Slave
3. 8 Collegamento
3. 9 Modalità DMX
3. 10 Indirizzamento DMX
3. 11 Collegamenti della linea DMX
3. 12 Costruzione del terminatore DMX
3. 13 Canali DMX
3. 14 Dimmer
3. 15 Back Light
3. 16 Informazioni sul dispositivo
3. 17 Frequenza LED
3. 18 Temperatura
3. 19 Modalità ventola
3. 20 Bilanciamento biannco
4 Manutenzione
4. 1 Manutenzione e pulizia del sistema ottico
4. 2 Sostituzione fusibile
4. 3 Risoluzione dei problemi
4
4
5
5
7
8
9
9
10
11
11
12
12
12
12
12
14
14
15
16
16
16
16
16
17
17
18
18
18

MINIVERSAPAR
4
ATTENZIONE! Prima di effettuare qualsiasi operazione con l’unità, leggere con attenzione
questo manuale e conservarlo accuratamente per riferimenti futuri. Contiene informazioni
importanti riguardo l’installazione, l’uso e la manutenzione dell’unità.
SICUREZZA
Avvertenze generali
• I prodotti a cui questo manuale si riferisce sono conformi alle Direttive della Comunità Europea e per-
tanto recano la sigla .
• Il dispositivo funziona con pericolosa tensione di rete 230V~. Non intervenire mai al suo interno al di
fuori delle operazioni descritte nel presente manuale; esiste il pericolo di una scarica elettrica.
• È obbligatorio eettuare il collegamento ad un impianto di alimentazione dotato di un’eciente messa
a terra (apparecchio di Classe I secondo norma EN 60598-1). Si raccomanda, inoltre, di proteggere le
linee di alimentazione delle unità dai contatti indiretti e/o cortocircuiti verso massa tramite l’uso di
interruttori dierenziali opportunamente dimensionati.
• Le operazioni di collegamento alla rete di distribuzione dell’energia elettrica devono essere eettuate
da un installatore elettrico qualicato. Vericare che frequenza e tensione della rete corrispondono alla
frequenza ed alla tensione per cui l’unità è predisposta, indicate sulla targhetta dei dati elettrici.
• L’unità non per uso domestico, solo per uso professionale.
• Evitare di utilizzare l’unità:
- in luoghi soggetti a vibrazioni, o a possibili urti;
- in luoghi a temperatura superiore ai 40°C.
• Evitare che nell’unità penetrino liquidi inammabili, acqua o oggetti metallici.
• Non smontare e non apportare modiche all’unità.
• Tutti gli interventi devono essere sempre e solo eettuati da personale tecnico qualicato. Rivolgersi al
più vicino centro di assistenza tecnica autorizzato.
• Se si desidera eliminare il dispositivo denitivamente, consegnarlo
per lo smaltimento ad un’istituzione locale per il riciclaggio.
Attenzioni e precauzioni per l’installazione
• Se il dispositivo dovesse trovarsi ad operare in condizioni dierenti da quelle descritte nel presente
manuale, potrebbero vericarsi dei danni; in tal caso la garanzia verrebbe a decadere. Inoltre, ogni altra
operazione potrebbe provocare cortocircuiti, incendi, scosse elettriche, rotture etc.
• Prima di iniziare qualsiasi operazione di manutenzione o pulizia sull’unità togliere la tensione dalla rete
di alimentazione.
• È assolutamente necessario proteggere l’unità per mezzo di una fune di sicurezza. Nell’eseguire qual-
siasi intervento attenersi scrupolosamente a tutte le normative (in materia di sicurezza) vigenti nel
paese di utilizzo.
• Installare l’unità in un luogo ben ventilato.
• Mantenere i materiali inammabili ad una distanza di sicurezza dall’unità.
• I ltri, le lenti o gli schermi ultravioletti se danneggiati possono limitare la loro ecienza.
• I LED devono essere sostituiti se danneggiati o termicamente deformati.
• Non guardare direttamente il fascio luminoso. Tenete presente che i veloci cambi di luce possono pro-
vocare attacchi d’epilessia presso persone fotosensibili o epilettiche.
• Non toccare l’alloggiamento del prodotto quando è in funzione perché potrebbe essere molto caldo.

5
MINIVERSAPAR
- 1 - INTRODUZIONE
1.1 DESCRIZIONE
MINIVERSAPAR è una nuova generazione di ParLED zoom, progettato per rental-company, con diverse
applicazioni sia per stage che per illuminazione architetturale, in ambienti di grandi e medie dimensio-
ni. Il caratteristico sistema ottico a singola lente con bordi piano-convessi migliora la fonte dei 7x10W
RGBW/FC LED grazie ad una tecnica di riessione in cui i colori vengono pre miscelati in canali ottici. Un
accorgimento tecnico permette un naturalismo cromatico non semplice da raggiungere per proiettori
LED di vecchia generazione. MINIVERSAPAR possiede anche uno zoom 10°-60° per ottenere feetti beam
con grande denizione o ampi angoli per eetti wash. In tutta la gamma di zoom vengono mantenuti
l’eccellente ecienza e la perfetta uniformità cromatica. MINIVERSAPAR è un proiettore sviluppato per
uso professionale orendo nuove tecnologie dimmer con andamenti super lineari e anti-ickering, con
settaggi di frequenza per l’interfaccia utente. L’assoluta operatività silenziosa del MINIVERSAPAR lo rende
utile anche in ambienti silenziosi o in applicazioni con un gran numero di unità.
1.2 SPECIFICHE TECNICHE
SORGENTE LUMINOSA
• Source:7 x 10 W RGBW LEDs
• CT:White 6701 K
• Lux:(10°) 4415 lux, (35°) 378 lux @3m
• Source Life Expectancy: >50.000 h
OTTICA
• Zoom: ° Motorised linear zoom
• Beam Angle:10° -35 °
• Lens Type: HQ glass lens optics
SISTEMA COLORE
• Color Mixing: RGBW/FC
• Color Wheel: Virtual color wheel with presets
• Macros: Several pre-build pixel macros with adjustable speed
EFFETTI DINAMICI
• Static Color Mode: Selection of static color
• Manual Color Mode: Manual adjustment of color
• Auto Mode: Built-in programs with execution speed adjustment
• Sound Mode: Music activation through internal microphone, sensitivity contr.
CORPO
• Body: Sturdy die-cast aluminium body conceived for long-time durability
• Body Color: Black
CONTROLLO
• Protocols: DMX512
• Dmx Channels:5/6/11 ch
• Firmware Upgrade: Yes, via USB-DMX interface (UPBOX1) not included
• Master/Slave: for synchronized operation of more units linked in a chain

MINIVERSAPAR
6
ELETTRONICA
• Dimmer: Linear 0~100% electronic dimmer
• Dimmer Curves: Dierent dimming curves available
• Strobe/Shutter:1/28 Hz, electronic
• Operating Temperature: -10° ~ +40°
• Flicker: Flicker free operation
ALIMENTAZIONE
• Power Supply: 100-240V – 50/60Hz
• Power Consumption (at 230V):69,2 W
• Output (at 230V):54 units on a single power line
CARATTERISTICHE FISICHE
• Signal Connection: 3p+5p in/out
• Power Connection: PowerCON in
• USB: USB port for USB Wi-Fi receiver (optional)
• IP:30 Protective vent to prevent condensation, dust, compensate pressure
• Cooling: Forced air with low noise fan
• Dimensions (WxHxD):235x156x301 mm
• Weight:3,7 kg
Fig.1
223235
301
Disegno tecnico
Table of contents
Languages:
Other Tribe Dj Equipment manuals

Tribe
Tribe PROLIGHTS SMARTBATTENQ User manual

Tribe
Tribe FLATPAR6H User manual

Tribe
Tribe JETSPOT3 User manual

Tribe
Tribe JETSPOT1 User manual

Tribe
Tribe FLATPAR3H User manual

Tribe
Tribe LUMIPAR12UAW User manual

Tribe
Tribe JETBEAM1 User manual

Tribe
Tribe SUNRISE2 User manual

Tribe
Tribe LUMIPAR12UH3P User manual

Tribe
Tribe PIXROLL10UTRI User manual